4/10 Bosch Rexroth AG Industrial Hydraulics Type 4WRPH 6 RE 29028/01.05
Technical Data
General
Construction Spool type valve, operated directly, with steel sleeve
Actuation Proportional solenoid with position control, external amplifier
Type of mounting Subplate, mounting hole configuration NG6 (ISO 4401-03-02-0-94)
Installation position Optional
Ambient temperature range °C –20 … +50
Weight kg 2.3
Vibration resistance, test condition Max. 25 g, shaken in 3 dimensions (24h)
Hydraulic (measured with HLP 46,
ϑ
oil
= 40 °C ±5 °C)
Pressure fluid Hydraulic oil to DIN 51524 … 535, other fluids after prior consultation
Viscosity range recommended mm
2
/s 20 … 100
max. permitted mm
2
/s 10 … 800
Pressure fluid temperature range °C –20 … +80
Maximum permissible degree of Class 18/16/13
1)
contamination of pressure fluid
Purity class to ISO 4406 (c)
Flow direction See symbol
Nominal flow at l/min 2 4 12 15 24 40
∆p = 35 bar per notch
2)
Max. working pressure bar Port P, A, B: 315
Max. pressure bar Port T: 250
Operating limits at ∆p bar < 315 < 315 < 315 < 315 < 315 < 160
Pressure drop at valve
q
Vnom
: > q
N
valves bar < 315 < 315 < 315 < 280 < 250 < 100
Leakage cm
3
/min < 150 < 180 < 300 <15– < 500 < 900
at 100 bar
cm
3
/min <15– <15– <15– <180 < 300 < 450
Electrical
Cyclic duration factor % 100 ED
Power supply 24 V
nom
(external amplifier)
Degree of protection IP 65 to DIN 40050
Solenoid connector Connector DIN 43650/ISO 4400 M16 x 1.5 (2P + PE)
Position transducer connector Special Connector Pg7 (4P)
Max. solenoid current A 2.7
Coil restistance R
20
Ω 2.5
Max. power consumption at 100 % load VA 40
and operational temperature
Position transducer Supply: +15 V/35 mA Signal: 0...±10 V (R
L
10 kΩ)
DC/DC technology Supply: –15 V/35 mA
Static/Dynamic
Hysteresis % 0.2
Manufacturing tolerance for q
max.
% 10
Response time for signal change ms 10
0 … 100 %
Thermal drift Zero point displacement 1 % at ∆T = 40 °C
1)
The purity classes stated for the components must be complied with in hydraulic systems. Effective filtration prevents problems and
also extends the service life of components. For a selection of filters, see catalogue sections RE 50070, RE 50076 and RE 50081.
2)
Durchfluss bei anderem ∆p
∆p
x
2)
Flow rate at a different ∆pq
x
= q
nom
·
35