RE 29014, edition: 2015-05, Bosch Rexroth AG
Proportional directional valve, direct operated,
with pQ functionality
Features
3-way proportional directional valve with integrated
IAC-P digital control electronics
Completely adjusted unit consisting of position-con-
trolled valve, pressure sensor and field bus connection
Operation via a proportional solenoid with central
thread and detachable coil
Valve spool, position-controlled
Integrated pressure sensor plate (optional)
ISO4401 porting pattern
Analog interfaces for command and actual values
Design for CAN bus with DS408 CANopen protocol or
DP Profibus
Quick commissioning via PC and WINPED commission-
ing software
Sizes: 6 and 10
Component series 1X, 2X
RE 29014 
Edition: 2015-05
Replaces: 2013-03
H8064
Type STW 0195 and STW 0196
Contents
Features 1
Ordering code 2
Symbols 2
Set-up, function, section 3
Technical data 4, 5
Characteristic curves 6 ... 8
Performance limits 9, 10
Dimensions 11 ... 13
Electrical connections, assignment 14, 15
Accessories 16, 17
Project planning and maintenance instructions 18
Further information 18
Contents
Features 1
Ordering codes 2
Symbols 2
Set-up, function, section 3
Technical data
(For applications outside these parameters please consult
us!) 4
Technical data
(For applications outside these parameters please consult
us!) 5
Characteristic curves: Size 6 (“0195…1”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C) 6
Characteristic curves: Size 10 (“0196…1”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C) 6
Characteristic curves
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C) 7
Characteristic curves: Size 6 (“0195…”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C) 8
Characteristic curves: Size 10 (“0196”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C) 8
Performance limits: Size 6 (“0195…”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C) 9
Performance limits: Size 10 (“0196”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C) 10
Dimensions: Size 6 (“0195”)
(dimensions in mm) 11
Dimensions: Size 10 (“0196”)
(dimensions in mm) 12
Dimensions 13
Electrical connections, assignment 14
Electrical connections, assignment 15
Accessories (separate order) 16
3 16
1 16
2 16
Accessories (separate order) 17
Project planning and maintenance instructions 18
Further information 18
Notes 19
Notes 20
2/18 STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG, RE 29014, edition: 2015-05
Ordering codes
01 3-way proportional directional valve with integrated IAC-P digital control electronics STW
02 Size 6 0195
Size 10 0196
03 Component series 10 … 19 (10 … 19: unchanged installation and connection dimensions) - size 10 1X
Component series 20 … 29 (20 … 29: unchanged installation and connection dimensions) - size 6 2X
Rated flow
04 – Size 6 (model “0195”)
P → A: 10 l/min, A → T: 20 l/min 1
P → A: 20 l/min, A → T: 20 l/min 2
– Size 10 (model “0196”)
P → A: 65 l/min, A → T: 60 l/min, B → T: 60 l/min 1
Seal material
05 FKM seals V
Observe compatibility of seals with hydraulic fluid used! (Other seals upon request)
Pressure rating of the integrated pressure sensor
06 Nominal pressure: 50 bar 3
Nominal pressure: 160 bar 5
Nominal pressure: 250 bar 8
Supply voltage
07 Direct voltage 24 V 24
Bus interface
08 CANBus DS - 408 C
Profibus DP V0/V1 P
Interface
09 ± 10 VDC A6
4 … 20 mA F6
10 Further details in the plain text *
01 02 03 04 05 06 07 08 09 10
STW / V 24 *
Symbols
Version “0195” Version “0196”








Proportional directional valve | STW 0195; STW 0196 3/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Set-up, function, section
Set-up
The IAC-P valve basically consists of:
Housing (1) with connection surface
Control spool (2) with compression spring (3)
Solenoid and pole tube (4) with central thread
Position transducer (5)
Pressure sensor (6)
Integrated IAC-P digital control electronics (7) with
bus connection (X2) and central connector (X1).
Functional description
If solenoids (4) are not operated, spool position A → T
(with type STW 0196-1X/1 additionally B → T)
Functions:
Flow control (Q)
Pressure control (p)
Override control p/Q
The command value can be defined either via an analog
interface (X1) or via the field bus interface (X2, X3).
The actual value signals are provided via an analog
interface (X1) and may be read additionally via the field
bus (X2, X3).
The controller parameters are set via the field
bus (X2, X3).
Separate supply voltage for bus/controller and power
part (output stage) for safety reasons
Type STW0195-2X/…
The digital integrated control electronics enables the
following fault detection (diagnostics):
Cable break of pressure sensor supply line (6)
Undervoltage
Cable break position transducer (5)
Communication error
Watchdog
Cable break of command value inputs
The following additional functions are available:
Pressure ramp
Internal command value profile
Release function analog/digital
Error output 24 V.
WINPED PC program
To implement the project planning task and to parameter-
ize the IAC-P valves, the user may use the WINPED com-
missioning software (see accessories).
Parameterization
Diagnostics
Comfortable data administration on a PC
PC operating systems: Windows 2000 or Windows XP
Q
command
Q control p closed-loop control
< 12 mA A T inactive
> 12 mA Override closed-loop control: (A T or P A)
Q control (Q
command
) with pressure limitation (p
command
)
if pressure limitation is active, the following
applies: Q
actual
Q
command
1)
Only available with
Profibus
Notice:
Due to the design principle, internal leakage is inherent to the
valves, which may increase over the life cycle.
The tank line must not be allowed to run empty. If required by
the installation conditions, use a suitable preload valve.
Notice:
The PG fitting (8) must not be opened. Mechanical adjustment
of the adjustment nut located below is prohibited and damages
the valve!
4/18 STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG, RE 29014, edition: 2015-05
General
Size S 6 (“0195”) 10 (“0196”)
Weight kg 2.4 6.5
Installation position any, preferably horizontal
Ambient temperature range °C -20 … +50
Storage temperature range °C -20 … +80
Hydraulic
1)
Operating pressure
2)
Ports P, A, B
(with sensor)
“3” bar 50
“5” bar 160
“8” bar 250
Port T
(with sensor)
“3” bar 50
“5” bar 160
“8” bar 210
Rated flow q
V
nom
(with ∆p = 5 bar; see also
characteristic curves starting
on page 7)
P → A “1” l/min 10 65
“2” l/min 20
A → T “1” l/min 20
“2” l/min 20
A → T, B → T “1” l/min 60
Max. flow l/min See performance limit starting on page 9
Hydraulic fluid See table below
Hydraulic fluid temperature range (at the valve operating
ports)
°C -20 ... +80; preferably +40 ... +50
Viscosity range mm
2
/s 20 ... 380; preferably 30 ... 46
Maximum admissible degree of contamination of the hydraulic fluid,
cleanliness class according to ISO 4406 (c)
Class 20/18/15
3)
Hysteresis % ≤ 0.1
Range of inversion % ≤ 0.05
Response sensitivity % ≤ 0.05
Zero shift %10 K ≤ 0.15
%100 bar ≤ 0.1
1)
Measured using HLP 46; ϑ
Oil
= 40 °C ± 5 °C and p = 100 bar
2)
Operating pressure, dependent on valve and sensor
Technical data
(For applications outside these parameters please consult us!)
Hydraulic fluid Classification Suitable sealing materi-
als
Standards Data sheet
Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN 51524 90220
Bio-degradable Insoluble in water HETG NBR, FKM ISO15380 90221
HEES FKM
Soluble in water HEPG FKM ISO15380
Flame-resistant Water-free HFDU, HFDR FKM ISO12922 90222
Containing water HFC (Fuchs Hydrotherm 46M,
Petrofer Ultra Safe 620)
NBR ISO12922 90223
Important information on hydraulic fluids:
For more information and data about the use of other hydraulic
fluids, refer to data sheets above or contact us!
There may be limitations regarding the technical valve data
(temperature, pressure range, life cycle, maintenance intervals,
etc.)!
The flash point of the hydraulic fluid used must be 40 K higher
than the maximum solenoid surface temperature.
Flame-resistant – containing water:
Maximum pressure differential per control edge 50 bar
Pressure pre-loading at the tank port > 20% of the pressure
differential, otherwise increased cavitation
Life cycle as compared to operation with mineral oil HL, HLP
50 to 100%
Bio-degradable and flame-resistant: When using these hydraulic
fluids that are simultaneously zinc-solving, zinc may accumulate
(700mg zinc per pole tube).
3)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents
faults and at the same time increases the life cycle of the com-
ponents.
For the selection of the filters see www.boschrexroth.com/filter.
Proportional directional valve | STW 0195; STW 0196 5/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Technical data
(For applications outside these parameters please consult us!)
electrical
Supply voltage Nominal voltage VDC 24
Lower limit value VDC 19.4
Upper limit value VDC 35
Maximum admissible residual ripple Vpp 2
Current consumption
I
max
A 2
Impulse current A 3
Command value signals mA 4 ... 20 (or via CAN bus)
Duty cycle
1)
% 100
Maximum coil temperature
2)
°C 150
Protection class according to DIN EN 60529 IP 65 with mating connector correctly mounted and locked
1)
Connect the valve to the supply voltage only when this is required
for the functional processes of the machine.
2)
Due to the surface temperatures of the solenoid coils, the
standards ISO13732-1 and ISO 4413 need to be adhered to!
3)
related to the complete measurement range, including non-lin-
earity, hysteresis, zero point and end value deviation
(corresponds to the measuring deviation according to IEC61298-2)
Sensor technology
Measurement range p
N
bar 50 160 250
Overload protection p
max
bar 110 320 500
Bursting pressure p bar 200 640 1000
Temperature coefficient for zero point and range within
the nominal temperature range
3)
< 0.1% / 10 K
Characteristic curve
deviation
< 0.2%
Hysteresis < 0.1%
Repetition accuracy < 0.05%
Setting time (10 ... 90%) t < 1 ms
Long-term drift (1 year) under reference conditions < 0.1%
Conformity CE according EMC directive EN61000-6-2 / EN61326-2-3 and
EN61000-6-3 / EN61326-2-3
























































6/18
STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG, RE 29014, edition: 2015-05
Characteristic curves: Size 6 (“0195…1”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C)
Characteristic curves: Size 10 (“0196…1”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C)
Transition function (A → T)
Transition function (A → T and B → T)
Stroke in % Stroke in %
Stroke in % Stroke in %
Time in ms
Time in ms
Time in ms
Time in ms
Transition function (P → A)
Transition function (P → A)

    




















 







  

Proportional directional valve | STW 0195; STW 0196 7/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Characteristic curves
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C)
Frequency response, Size 6 (“0195…1”)
Frequency response, Size 10 (“0196…1”)
Amplitude ratio in dB
Frequency in Hz
Phase angle in %
Amplitude ratio in dB
Frequency in Hz
Phase angle in %
Signal ± 10%
Signal ± 25%
Signal ± 100%
Signal ± 10%
Signal ± 25%
Signal ± 100%



















  







 



8/18 STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG, RE 29014, edition: 2015-05
Characteristic curves: Size 6 (“0195…”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C)
Flow characteristic curve (A → T, ∆p = 5 bar)
Command value in %
Flow in l/min.
Command value in %
Flow in l/min.
Flow characteristic curve (P → A, ∆p = 5 bar)
Characteristic curves: Size 10 (“0196”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C)
Flow characteristic curve (A/B → T, ∆p = 5 bar)
Flow characteristic curve (P → A, ∆p = 5 bar)
Command value in %
Flow in l/min.
Command value in %
Flow in l/min.
3 A → T
4 B → T
1 Version “0195…1”)
2 Version “0195…2”)





  
 

 















  
 







 



Proportional directional valve | STW 0195; STW 0196 9/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Performance limits: Size 6 (“0195…”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C)
Position-controlled
(P → A: 10 l/min, A → T: 20 l/min – A T)
Pressure differential in bar
Flow in l/min.
Position-controlled
(P → A: 10 l/min, A → T: 20 l/min – P A)
Pressure differential in bar
Flow in l/min.
Pressure differential in bar
Flow in l/min.
Pressure differential in bar
Flow in l/min.
Position-controlled
(P → A: 20 l/min, A → T: 20 l/min – A T)
Position-controlled
(P → A: 20 l/min, A → T: 20 l/min – P A)










    










    








10/18 STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG, RE 29014, edition: 2015-05
Performance limits: Size 10 (“0196”)
(measured with HLP46, ϑ
Oil
= 40 ± 5 °C)
Position-controlled (A → T)
Pressure differential in bar
Flow in l/min.
Position-controlled (P → A)
Pressure differential in bar
Flow in l/min.
Pressure differential in bar
Flow in l/min.
Position-controlled (B → T)
0,01/100
Rzmax 4


























Proportional directional valve | STW 0195; STW 0196 11/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Dimensions: Size 6 (“0195”)
(dimensions in mm)
1 Valve housing
2 Proportional solenoid “b” with inductive position transducer
3 Integrated digital control electronics
4 Name plate
5 Space required to remove the connector
6 Machined valve contact surface
porting pattern according to ISO 4401-03-02-0-05
Deviating from the standard:
Ports P, A, B and T with Ø 8 mm
Locating pin not available
Subplates and valve mounting screws see page 13.
Note:
The dimensions are nominal dimensions which are
subject to tolerances.
Required surface quality
of the valve contact surface
0,01/100
Rzmax 4























 

12/18 STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG, RE 29014, edition: 2015-05
Dimensions: Size 10 (“0196”)
(dimensions in mm)
1 Valve housing
2 Proportional solenoid “b” with inductive position transducer
3 Integrated digital control electronics
4 Name plate
5 Space required to remove the connector
6 Machined valve contact surface
Porting pattern in accordance with ISO 4401-05-04-0-05
Deviating from the standard:
Port T1 exists additionally
Subplates and valve mounting screws see page 13.
Note:
The dimensions are nominal dimensions which are
subject to tolerances.
Required surface quality of the
valve contact surface
Proportional directional valve | STW 0195; STW 0196 13/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Dimensions
Valve mounting screws (separate order)
Size Hexagon socket head cap screws Material number
6 (“0195”) 4 hexagon socket head cap screws ISO 4762 - M5 x 50 - 10.9-flZn-240h-L
tightening torque M
A
= 7 Nm ± 10%
R913000064
4 hexagon socket head cap screws ISO 4762 - M5 x 50
Tightening torque M
A
= 8.9 Nm ± 10%
Not in the Rexroth delivery
range
10 (“0196”) 4 hexagon socket head cap screws ISO 4762 - M6 x 40 - 10.9-flZn-240h-L
tightening torque M
A
= 12.5 Nm ± 10%
R913000058
4 hexagon socket head cap screws ISO 4762 - M6 x 40 - 10.9
tightening torque M
A
= 15.5 Nm ± 10%
Not in the Rexroth delivery
range
Notice:
The tightening torque of the hexagon socket head cap screws
refers to the maximum operating pressure.
Subplates (separate order)
Size Data sheet Material number
6 (“0195”) 45052
10 (“0196”) 45054


14/18
STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG, RE 29014, edition: 2015-05
1)
Litz wire colors of the connection line for mating connector with
cable set (see accessories page 17)
Electrical connections, assignment
X1
Pin Core marking
1)
Interface A6 allocation Allocation Interface F6
1 1 24 VDC (u(t) = 19.4 V … 35 V), I
max
= 1.7 A (for output stage)
2 2 0 V ≙ load zero, reference for pins 1 and 9
3 white enable input 9 ... 35 V ≙ enable on
4 yellow ± 10 V command value Q, R
e
> 50 kΩ 4 … 20 mA command value Q, R
e
= 100 Ω
5 green Reference for command values Q and p
6 purple ± 10 V actual value Q 4 ... 20 mA actual value Q (load resistance max. 300 Ω)
7 pink 0 ... ± 10 V command value Q, R
e
> 50 kΩ 4 ... ± 20 mA command value p, R
e
= 100 kΩ
8 red 0 … 10 V actual value p 4 ... 20 mA actual value p (load resistance max. 300 Ω)
9 brown Control voltage, level as pin 1, I
max
= 0.3 A (for signal part and bus)
10 black 0V reference potential for pins 3, 6, 8 and 11 (connected with pin 2 in valve)
11 blue Error output 24 V (19.4 V … 35 V), 200 mA max. load
PE green-yellow Connected to cooling element and valve housing
Connector pin assignment X1, 11-pole + PE according to DIN EN 175201-804
Connector pin assignment X2, CAN bus, (coding A), M12 x 1, 5-pole, pins
Transmission rate 20 … 1000 kBit/s
Bus address 1 ... 127
CAN-specific settings:
Baud rate and identifier must be set via the
bus system.
Pin Assignment
1 n.c.
2 n.c.
3 CAN_GND
4 CAN_H
5 CAN_L
X2
Connector pin assignment for Profibus DP, “X2” /X3 (coding B), M12 x 1, 5-pole, socket / pins
Pin Assignment
1 +5V
2 RxD/TxD-N (A line)
3 D GND
4 RxD/TxD-P (B line)
5 Shield
Transmission rate up to 12MBaud
Bus address 1 ... 126
Setting via DIL switch
The +5V voltage of the IAC-P is available for an external terminating resistor.
X2
X3
Notice:
Connect shield to PE only on the supply side.
Notice:
We recommend connecting the shields on both sides via the
metal housings of the plug-in connectors.
Using connector pins will affect the shielding effect! Internal
screens are not required.



















Proportional directional valve | STW 0195; STW 0196 15/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Block diagram, integrated control electronics
CAN bus
Command
value q
Command
value p
Actual value q
Actual value p
Enable
Error output
24V load supply
24V signal
supply
GND
Output stage supply
Microcontroller
CAN
controller
Controller
Actual
pressure value
Output
stage off
Actual
value
position
Cable break
Output
stage
Oscillator
demodulator
Valve with inductive
positional transducer
Command value Command value 12 to 20 mA at pin 4 and reference potential at pin 5 result in flow from P A.
Command value 4 to 12 mA at pin 4 and reference potential at pin 5 result in flow from A T.
Actual value Actual value 12 to 20 mA at pin 6 and reference potential at pin 10 result in flow from P A.
Actual value 4 to 12 mA at pin 6 and reference potential at pin 10 result in flow from A → T.
Connection line
(recommended):
up to 25 m line length for pins 1, 2 and PE: 0.75mm
2,
, otherwise 0.25mm
2
up to 50 m line length for pins 1, 2 and PE: 1.00mm
2
External diameter see sketch of mating connector
Reference for
pins 4, 7
Reference for
pins 3, 6, 8, 11
Protective earth-
ing conductor
Electrical connections, assignment
Alternatively
Profibus
Profibus
controller
16/18 STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG, RE 29014, edition: 2015-05
Accessories (separate order)
3
1
2
The following is required for the parameter-
ization via PC:
CANopen Profibus DP
1 interface converter (USB) VT-ZKO-USB/CA-1-1X/V0/0
Material no.: R901071963
VT-ZKO-USB/P-1-1X/V0/0
Material no.: R901071962
2 Commissioning software WINPED
Download from www.boschrexroth.de\IAC
3 Connection cable, 3m D-Sub / M12, coding A
Material no.: R900751271
D-Sub / M12, coding B
Material no.: R901078053




Proportional directional valve | STW 0195; STW 0196 17/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Accessories (separate order)
Port X1
Mating connector for X1 Dimensions Material number
Mating connector according to DIN EN 17520-804
(11-pole + PE), plastic variant
Without cable (assembly kit) R900884671
With cable set 2 x 5 m 12-pole R900032356
With cable set 2 x 20 m 12-pole R900860399
CAN bus (A coding)
Plug-in connector for X2 View, dimensions Material number
Round connector, processable, 5-pole,
M12 x 1
Straight mating connector in metal
design


(line diameter 6 ... 8 mm)
R901076910
Profibus (B coding)
Plug-in connector for X2 and X3 View, dimensions Material number
X2
Round connector, processable, 5-pole,
M12 x 1
Straight mating connector in metal
design
Ø19,6
ca. 61
1
5
4
3
2
(line diameter 6 ... 8 mm)
R901075545
X3
Round connector, processable, 5-pole,
M12 x 1
Straight mating connector in metal
design


(line diameter 6 ... 8 mm)
R901075550
Protective cap
Protective cap M12 Version Material number
R901075563
Bosch Rexroth AG, RE 29014, edition: 2015-05
18/18
STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG
Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
documentation@boschrexroth.de
www.boschrexroth.de
© This document, as well as the data, specifications and other information set
forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without the consent of Bosch Rexroth AG.
The data specified only serve to describe the product. It cannot be used to
derive statements concerning a certain condition or suitability for a certain
application. This information also does not release the user from the obligation
of own judgment and verification.
It must be remembered that our products are subject to a natural process of
wear and aging.
Project planning and maintenance instructions
Connect the valve to the supply voltage only when this
is required for the functional processes of the machine.
Do not use electrical signals provided via control elec-
tronics (e.g. “No error” signal) for switching safety-rele-
vant machine functions (see also EN ISO 13849 “Safety
of machinery – safety-related parts of control systems”).
If electro-magnetic interference must be expected, take
appropriate measures to ensure the function (depend-
ing on the application, e.g. shielding, filtration).
The devices have been tested in the plant and are sup-
plied with default settings.
Only complete units can be repaired. Repaired devices
are returned with default settings. User-specific settings
are not maintained. The machine end-user will have to
retransfer the corresponding user parameters.
Further information
Subplates Data sheets 45052, 45054
Hydraulic fluids on mineral oil basis Data sheet 90220
Environmentally compatible hydraulic fluids Data sheet 90221
Flame-resistant, water-free hydraulic fluids Data sheet 90222
Hydraulic valves for industrial applications Data sheet 07600-B
Assembly, commissioning and maintenance of hydraulic systems Data sheet 07900
CANopen protocol for IFB-P and IAC-P valves, protocol description Data sheet 29015-01-Z
Profibus protocol for IFB and IAC-P valves, protocol description Data sheet 29015-02-Z
Proportional directional valves with field bus interface, with and without inte-
grated axis controller (IAC-P and IFB-P), operating instructions
Data sheet 29015-B
Commissioning software and documentation on the Internet www.boschrexroth.com/IAC
Selection of the filters www.boschrexroth.com/filter
Proportional directional valve | STW 0195; STW 0196 19/18
RE 29014, edition: 2015-05, Bosch Rexroth AG
Bosch Rexroth AG
Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
documentation@boschrexroth.de
www.boschrexroth.de
© This document, as well as the data, specifications and other information set
forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without the consent of Bosch Rexroth AG.
The data specified only serve to describe the product. It cannot be used to
derive statements concerning a certain condition or suitability for a certain
application. This information also does not release the user from the obligation
of own judgment and verification.
It must be remembered that our products are subject to a natural process of
wear and aging.
Notes
Bosch Rexroth AG, RE 29014, edition: 2015-05
20/18 STW 0195; STW 0196 | Proportional directional valve
Bosch Rexroth AG
Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
documentation@boschrexroth.de
www.boschrexroth.de
© This document, as well as the data, specifications and other information set
forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without the consent of Bosch Rexroth AG.
The data specified only serve to describe the product. It cannot be used to
derive statements concerning a certain condition or suitability for a certain
application. This information also does not release the user from the obligation
of own judgment and verification.
It must be remembered that our products are subject to a natural process of
wear and aging.
Notes