4/8 Bosch Rexroth AG Hydraulics
Z2FRM RE 28164/05.11
Technical Data (For applications outside these parameters, please consult us!)
general
Weight – Flow control function in channel A, B, T kg 1.3
– Flow control function in channel A, B kg 1.4
Installation position Any
Ambient temperature range °C –20 to +50
hydraulic
Maximum operating pressure bar 315
Minimum pressure differential – with q
V max
bar 18
– with q
V min
bar 7
Pressure stability up to ∆p = 315 bar % ±3 (q
V max
)
Maximum flow – q
V max
l/min 6; 32
– q
V min
cm
3
/min 50; 250
Hydraulic fluid See table below
Hydraulic fluid temperature range °C –20 to +80
Viscosity range mm
2
/s 10 to 800
Maximum permitted degree of contamination of the hydraulic fluid -
cleanliness class according to ISO 4406 (c)
Class 20/18/15
1)
1)
The cleanliness classes specified for the components must
be adhered to in hydraulic systems. Effective filtration pre-
vents faults and at the same time increases the service life
of the components.
For the selection of the filters see
www.boschrexroth.com/filter.
Hydraulic fluid Classification Suitable sealing materials Standards
Mineral oils and related hydrocarbons HL, HLP, HLPD FKM DIN 51524
Environmentally
compatible
– Insoluble in water
HETG FKM
ISO 15380
HEES FKM
– Soluble in water HEPG FKM ISO 15380
Flame-resistant – Water-free HFDU, HFDR FKM ISO 12922
Important information on hydraulic fluids!
– For more information and data on the use of other hydrau-
lic fluids refer to data sheet 90220 or contact us!
– There may be limitations regarding the technical valve
data (temperature, pressure range, service life, mainte-
nance intervals, etc.)!