4/8 Bosch Rexroth AG Hydraulics Z2FS RE 27506/05.11
Technical Data (For applications outside these parameters, please consult us!)
general
Weight kg Approx. 0.8
Installation position Any
Ambient temperature range °C –20 to +80
hydraulic
Maximum operating pressure bar 315
Maximum flow l/min 80
Hydraulic fluid See table below
Hydraulic fluid temperature range °C –20 to +80
Viscosity range mm
2
/s 10 to 800
Maximum permitted degree of contamination of the hydraulic fluid -
cleanliness class according to ISO 4406 (c)
Class 20/18/15
1)
1)
The cleanliness classes specified for the components must
be adhered to in hydraulic systems. Effective filtration pre-
vents faults and at the same time increases the service life
of the components.
For the selection of the filters see
www.boschrexroth.com/filter.
Hydraulic fluid Classification Suitable sealing materials Standards
Mineral oils and related hydrocarbons HL,HLP,HLPD NBR, FKM DIN 51524
Environmentally
compatible
– Insoluble in water
HETG NBR, FKM
ISO 15380
HEES FKM
– Soluble in water HEPG FKM ISO 15380
Flame-resistant
– Water-free HFDU, HFDR FKM ISO 12922
– Water-containing
HFC (Fuchs Hydrotherm 46M,
Petrofer Ultra Safe 620)
NBR ISO 12922
Important information on hydraulic fluids!
– For more information and data on the use of other hydrau-
lic fluids refer to data sheet 90220 or contact us!
– There may be limitations regarding the technical valve
data (temperature, pressure range, service life, mainte-
nance intervals, etc.)!
– Flame-resistant – water-containing:
• Maximumoperatingpressure210bar
• Maximumhydraulicfluidtemperature60°C
• ExpectedservicelifeascomparedtoHLPhydraulicoil
30 % to 100 %