4/6 Bosch Rexroth AG Hydraulics
Z1S 10 RE 21536/07.05
Function, section
Valves of type Z1S are direct operated check valves of sand-
wich plate design.
They are used to check a flow leak-free in one direction and al-
low free flow in the opposite direction.
The stroke of poppet (3) is limited by spring plate (4). An in-
tegrated spring (5) supports the closing movement. When no
fluid flows through the valve, spring (5) holds poppet (3) in the
closed position.
Type Z1S 10 ..-3X/V (with metal seal)
This valve version is provided with a metal seal between pop-
pet (3) and housing (1). Valves of this version are particularly
suitable for applications that involve operating pressures higher
than 100 bar and flow velocities of more than 4 m/s.
Type Z1S 10 ..1-3X/VW4 (with soft seal)
This valve version is fitted with a soft seal between poppet (3)
and housing (1) and provides hermetic sealing. Valves of this
version are particularly suitable for applications with flow veloc-
ities of up to 4 m/s and low operating pressures.
Type Z1S 10 A1-3X/V Type Z1S 10 A1-3X/VW4
Technical data (for applications outside these parameters, please consult us!)
1)
The cleanliness classes specified for components must be
adhered to in hydraulic systems. Effective filtration prevents
malfunction and, at the same time, prolongs the service life
General
Weight kg approx. 2.3
Installation orientation Optional
Ambient temperature range °C –20 to +80
Hydraulic
Maximum operating pressure bar 315
Cracking pressure – Metal seal bar 0.5; 3; 5
– Soft seal bar 0.5
Maximum flow l/min 100
Flow velocity – Metal seal m/s > 4
– Soft seal m/s < 4
Hydraulic fluid Mineral oil (HL, HLP) to DIN 51524; fast bio-degradable
hydraulic fluids to VDMA 24568 (see also RE 90221); HETG
(rape seed oil); HEPG (polyglycols); HEES (synthetic esters);
other hydraulic fluids on enquiry
Hydraulic fluid temperature range °C –20 to +80
Viscosity range mm
2
/s 2.8 to 500
Max. permissible degree of contamination of the
hydraulic fluid - cleanliness class to ISO 4406 (c)
Class 20/18/15
1)
of components.
For the selection of filters, see data sheets RE 50070,
RE 50076, RE 50081, RE 50086 and RE 50088.