Hydraulics Bosch Rexroth AG
RE 18375/04.12 KBVS
5/12
Technical data (For applications outside these parameters, please consult us!)
electric
Supply voltage V 12 DC 24 DC "-8" / 24 DC
Maximum control current mA 1760 1200 800
Coil resistance – Cold value at 20 °C Ω 2.3 4.8 11.5
– Max. hot value Ω 3.8 7.9 18.9
Duty cycle % 100
5)
Maximum coil temperature
6)
°C 150
Protection class according
to DIN EN 60529
– Version "K4" IP 65 with mating connector mounted and locked
– Version "K40" IP 69K with mating connector mounted and locked
– Version "C4" IP 66 with mating connector mounted and locked
IP 69K with Rexroth mating connector
(Material no. R901022127)
Control electronics
(separate order) – Plug-in proportional amplifier Type VT-SSPA1…, see data
sheet 30116
– Analog amplifier Type RA…, see data sheet 95230
– BODAS control unit Type RC…, see data sheet 95200
Design according to VDE 0580
hydraulic
Hysteresis
4)
< 4 % of the maximum set pressure
Range of inversion
4)
< 0.5 % of the maximum set pressure
Response sensitivity
4)
< 0.5 % of the maximum set pressure
Manufacturing tolerance of
the command value/pressure
characteristic curve
– Command value 100 % < 2 % of the maximum set pressure
– Command value 0 < 5 % of the maximum set pressure
Step response (T
u
+ T
g
) 0 → 100 % and/or 100 % → 0 ms 100 (depending on the system)
4)
Measured with analog amplifier type RA2-1/10, see data
sheet 95230
5)
In the case of use at heights > 2000 m above MSL, please
consult us.
6)
Due to the temperatures occurring at the surfaces of the
solenoid coils, the standards ISO 13732-1 and EN 982
need to be adhered to!
In the electrical connection, the protective earthing
conductor (PE
) is to be connected properly.
Hydraulic fluid Classification Suitable sealing materials Standards
Mineral oils and related hydrocarbons HL, HLP, HLPD, HVLP, HVLPD FKM DIN 51524
Environmentally
compatible
– Insoluble in water
HEES FKM
ISO 15380
HEPR FKM
– Soluble in water HEPG FKM ISO 15380
Flame-resistant
– Water-free HFDU, HFDR FKM ISO 12922
– Water-containing HFAS FKM ISO 12922
Important information on hydraulic fluids!
– For more information and data on the use of other hydrau-
lic fluids refer to data sheet 90220 or contact us!
– There may be limitations regarding the technical valve
data (temperature, pressure range, service life, mainte-
nance intervals, etc.)!
– The flash point of the process and operating medium used
must be 40 K higher than the maximum solenoid sur-
face temperature.
– Flame-resistant – water-containing: Maximum pressure
differential per control edge 175 bar; otherwise, increased
cavitation erosion!
Tank pre-loading < 1 bar or > 20 % of the pressure differ-
ential. The pressure peaks should not exceed the maxi-
mum operating pressures!
– Environmentally compatible: When using environmen-
tally compatible hydraulic fluids that are simultaneously
zinc-solving, zinc may accumulate in the medium (700 mg
zinc per pole tube).