1/2
VCSQ-10A 04.84.06 - X - 85 - Z
Logic element, pressure
compensator combination type
Common cavity, Size 10
Flow is normally allowed from 4 to 3. When pilot pressure at 1 rises
above the combined pressure of the spring bias, plus pressure at 4,
the valve shifts to block flow between 3 and 4, while diverting flow
from 1 to 2. A constant pressure drop is maintained across a fixed
(or variable) orifice upstream of 4 when installed and piloted per the
diagram above. In this case, flow priority is given to 3, with flow in
excess of the orifice differential requirement being by-passed to 2.
Technical data
Description
Performance
RE 18321-80/01.10
Replaces: RE 00162-02/01.06
Max. operating pressure bar (psi) 350 (5000)
Max. intel flow l/min. (gpm)
60 (16)
Max. priority flow l/min. (gpm) 40 (11)
Flow maintenance ±10%
Fluid temperature range °C (°F) -30 to 100 (-22 to 212)
Installation torque Nm (ft-lbs) 41-47 (30-35)
Weight kg (lbs) 0.14 (0.31)
Cavity
CA-10A-4N
see data sheet RE 18325-70
Seal kit (*)
code
material no.
RG10A4010530100
R901111373
Fluids
Mineral-based or synthetics
with lubricating properties at
viscosities of 10 to 500 mm
2
/s (cSt)
Filtration
Nominal value max. 10µm (NAS 8)
ISO 4406 19/17/14
Installation No restrictions
Other Technical Data See data sheet RE 18350-50
(*) Only external seals for 10 valves