RE 92801/03.2018, Bosch Rexroth AG
Axial piston variable pump | A15VSO, A15VLO Series 11
Project planning notes
65
Project planning notes
▶ The A15V(L)O axial piston variable pump is designed to
be used in open circuits.
▶ The project planning, installation and commissioning of
the axial piston unit requires the involvement of quali-
fi ed skilled personnel.
▶ Before using the axial piston unit, please read the cor-
responding instruction manual completely and thor-
oughly. If necessary, this can be requested from
BoschRexroth.
▶ Before fi nalizing your design, please request a binding
installation drawing.
▶ The specifi ed data and notes contained herein must be
observed.
▶ Depending on the operating conditions of the axial
piston unit (working pressure, fl uid temperature), the
characteristic curve may shift.
▶ The characteristic curve may also shift due to the dither
frequency or control electronics.
▶ Preservation: Our axial piston units are supplied as
standard with preservative protection for a maximum of
12 months. If longer preservative protection is required
(maximum 24 months), please specify this in plain text
when placing your order. The preservation periods apply
under optimal storage conditions, details of which can
be found in the data sheet 90312 or in the instruction
manual.
▶ Not all versions of the product are approved for use in a
safety function according to ISO13849. Please consult
the responsible contact person at Bosch Rexroth if you
require reliability parameters (e.g.MTTF
d
) for functional
safety.
▶ Depending on the type of control used, electromagnetic
eff ects can be produced when using solenoids. Applying
the recommended direct voltage signal (DC) to sole-
noids does not create electromagnetic interference
(EMI) nor is the solenoid aff ected by EMI. Electromag-
netic interference (EMI) potential exists when operating
and controlling a solenoid with a modulated direct
voltage signal (e.g. PWM signal). Appropriate testing
and measures should be taken by the machine manufac-
turer to ensure other components or operators (e.g.
with pacemaker) are not aff ected by this potential.
▶ Pressure controllers are not safeguards against pressure
overload. Be sure to add a pressure relief valve to the
hydraulic system.
▶ For drives that are operated for a long period with
constant rotational speed, the natural frequency of the
hydraulic system can be stimulated by the stimulator
frequency of the pump (rotational speed frequency ×9).
This can be prevented with suitably designed hydraulic
lines.
▶ Working ports:
– The ports and fastening threads are designed for the
specifi ed maximum pressure. The machine or system
manufacturer must ensure that the connecting ele-
ments and lines correspond to the specifi ed applica-
tion conditions (pressure, fl ow, hydraulic fl uid, tem-
perature) with the necessary safety factors.
– The working ports and function ports are only
intended to accommodate hydraulic lines.