350LEN_d
RE 51422, edition: 2015-03, Bosch Rexroth AG
Contents
Features 1
Filter ordering code 2, 3
Preferred types 4
Accessories ordering code 5
Symbols 6
Function, cross-section 7
Technical data 8, 9
Compatibility with permitted hydraulic fluids 10
Characteristic curves 11-14
Dimensions 15
Maintenance indicator 16
Spare parts ordering codes 17-19
Assembly, commissioning, maintenance 20
Tightening torques 21
Directives and standardization 21, 22
Inline filter with filter element according to DIN 24550
Features
Inline filters are used in hydraulic systems for separating
solid materials from fluids and lubricating oils.
They come with the following features:
Filter for inline installation
Special, highly efficient filter materials
Filtration of very fine particles and high dirt holding
capacity across a broad pressure differential range
High collapse rating of the filter elements
Equipped standard with mechanical optical mainte-
nance indicator with memory function
Various, optional electronic switching elements,
modular design
Optional bypass valve integrated in the filter housing
High filtration performance due to tangential,
cyclonic flow path
Additional configurations available for special fluids
Size as per DIN 24550: 0040 to 1000
Other sizes: 0130, 0150
Nominal pressure: 350 bar [5,079 psi]
Connection sizes up to G2; SAE 2"; SAE 24
Operating temperature: -10 °C to 100 °C [14 °F to 212 °F]
RE 51422 
Edition: 2015-03
Replaces: 07.11
Type 350LEN0040 to 1000; 350LE0130, 0150
2/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Filter ordering code
Series
01 Inline filter, 350 bar [5,079 psi] 350LE
Filter element
02 With filter element as per DIN 24550 N
Size
03 LEN...
(Filter element as per DIN 24550)
0040
0063
0100
0160
0250
0400
0630
1000
LE...
(Filter element as per Bosch Rexroth standard)
0130
0150
Filter rating in μm
04 Absolute
(ISO 16889; β
x(c)
≥ 200)
Glass fiber material, not cleanable H3XL
H6XL
H10XL
H20XL
Nominal Stainless steel wire mesh, cleanable G10
G25
G40
G60
G100
Pressure differential
05 Max. admissible filter element pressure differential: 30bar [435 psi], filter with bypass valve A
Max. admissible filter element pressure differential: 330bar [4,786 psi], filter has no bypass valve B
Element design
06 Standard adhesive with galvanized steel 00
Special adhesive with stainless steel HV
1)
Maintenance indicator
07 Maintenance indicator, mech. visual, switching pressure: 2.2 bar [32 psi] ‒ bypass cracking pressure: 3.5 bar [51 psi] V2.2
Maintenance indicator, mech. visual, switching pressure: 5.0 bar [72.5 psi] ‒ bypass cracking pressure: 7 bar [102 psi] V5.0
Maintenance indicator, mech. visual, switching pressure 8.0 bar [116 psi]no bypass valve V8.0
Seal
08 NBR seal M
FKM seal V
EPDM seal E
2)
01 02 03 04 05 06 07 08 09 10
350LE
Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 3/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Filter ordering code
Connection
09 Installation size
0040 0063-0100 0130-0150 0160-0400 0630-1000
Connection
G1/2
Pipe thread as per
ISO 228
X R2
G3/4 X X R3
G1 X X R4
G1 1/4 X R5
G1 1/2 X R6
G2 R8
SAE 1 1/2"
SAE flange 6,000 psi
X S6
SAE 2" X S8
SAE 10"
Pipe thread as per
SAE J1926
X U3
SAE 12" X U4
SAE 20" X U5
SAE 24" X U6
Standard connection
X
Alternative connection option
Supplementary information
10 Manufacturer's inspection certificate M as per DIN 55350 T18 Z1
1)
Only with FKM or EPDM seal
2)
Only with maintenance indicator V5.0
Order example:
350LEN0100-H10XLA00-V5.0-M-R4
Other versions are available on request.
01 02 03 04 05 06 07 08 09 10
350LE
4/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Preferred types
350LE(N), flow specifications for 30 mm²/s [143 SUS]
Inline filter, 3 μm filter rating
Type
Flow
in l/min [US gpm] whereas
Δp = 1.5 bar [21.76 psi]
1)
Material no.
Filter
Replacement
element
material no.
350LEN0040-H3XLA00-V5.0-M-... 32 [8.5] ...R2 R928033024 ...U3 R928033216 R928006645
350LEN0063-H3XLA00-V5.0-M-... 48 [12.7] ...R4 R928033025 ...U4 R928033217 R928006699
350LEN0100-H3XLA00-V5.0-M-... 64 [16.9] ...R4 R928033026 ...U4 R928033218 R928006753
350LE0130-H3XLA00-V5.0-M-... 103 [27.2] ...R5 R928033027 ...U5 R928033219 R928022274
350LE0150-H3XLA00-V5.0-M-... 127 [33.6] ...R5 R928033028 ...U5 R928033220 R928022283
350LEN0160-H3XLA00-V5.0-M-... 160 [42.3] ...R6 R928033029 ...U6 R928033221 R928006807
350LEN0250-H3XLA00-V5.0-M-... 267 [70.5] ...R6 R928033030 ...U6 R928033222 R928006861
350LEN0400-H3XLA00-V5.0-M-... 335 [88.5] ...R6 R928033031 ...U6 R928033223 R928006915
350LEN0630-H3XLA00-V5.0-M-... 449 [118.6] ...R8 R928034432 ...S8 R928034448 R928006969
350LEN1000-H3XLA00-V5.0-M-... 597 [157.7] ...R8 R928034433 ...S8 R928034449 R928007023
Inline filter, 6 μm filter rating
Type
Flow
in l/min [US gpm] whereas
Δp = 1.5 bar [21.76 psi]
1)
Material no.
Filter
Replacement
element
material no.
350LEN0040-H6XLA00-V5.0-M-... 41 [10.8] ...R2 R928033280 ...U3 R928033472 R928006646
350LEN0063-H6XLA00-V5.0-M-... 69 [18.2] ...R4 R928033281 ...U4 R928033473 R928006700
350LEN0100-H6XLA00-V5.0-M-... 104 [27.5] ...R4 R928033282 ...U4 R928033474 R928006754
350LE0130-H6XLA00-V5.0-M-... 125 [33] ...R5 R928033283 ...U5 R928033475 R928022275
350LE0150-H6XLA00-V5.0-M-... 135 [35.7] ...R5 R928033284 ...U5 R928033476 R928022284
350LEN0160-H6XLA00-V5.0-M-... 265 [70] ...R6 R928033285 ...U6 R928033477 R928006808
350LEN0250-H6XLA00-V5.0-M-... 320 [84.5] ...R6 R928033286 ...U6 R928033478 R928006862
350LEN0400-H6XLA00-V5.0-M-... 400 [105.7] ...R6 R928025783 ...U6 R928033479 R928006916
350LEN0630-H6XLA00-V5.0-M-... 520 [137.4] ...R8 R928034464 ...S8 R928034480 R928006970
350LEN1000-H6XLA00-V5.0-M-... 635 [167.8] ...R8 R928034465 ...S8 R928034481 R928007024
Inline filter, 10 μm filter rating
Type
Flow
in l/min [US gpm] whereas
Δp = 1.5 bar [21.76 psi]
1)
Material no.
Filter
Replacement
element
material no.
350LEN0040-H10XLA00-V5.0-M-... 51 [13.5] ...R2 R928033536 ...U3 R928033728 R928006647
350LEN0063-H10XLA00-V5.0-M-... 76 [20.1] ...R4 R928033537 ...U4 R928033729 R928006701
350LEN0100-H10XLA00-V5.0-M-... 100 [26.4] ...R4 R928033538 ...U4 R928033730 R928006755
350LE0130-H10XLA00-V5.0-M-... 191 [50.5] ...R5 R928025653 ...U5 R928033731 R928022276
350LE0150-H10XLA00-V5.0-M-... 202 [53.4] ...R5 R928028868 ...U5 R928033732 R928022285
350LEN0160-H10XLA00-V5.0-M-... 261 [69] ...R6 R928033541 ...U6 R928033733 R928006809
350LEN0250-H10XLA00-V5.0-M-... 330 [87.2] ...R6 R928033542 ...U6 R928033734 R928006863
350LEN0400-H10XLA00-V5.0-M-... 409 [108.1] ...R6 R928033543 ...U6 R928033735 R928006917
350LEN0630-H10XLA00-V5.0-M-... 590 [155.9] ...R8 R928034496 ...S8 R928034512 R928006971
350LEN1000-H10XLA00-V5.0-M-... 650 [171.7] ...R8 R928034497 ...S8 R928034513 R928007025
1)
Measured pressure differential across filter and measuring
equipment in accordance with ISO 3968. The measured pressure
differential at the maintenance indicator is lower.










Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 5/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Accessories ordering code
(dimensions in mm [inch])
Electronic switching element for maintenance indicators
Maintenance indicator
01 Electronic switching element WE
Type of signal
02 1 switching point 1SP
2 switching points, 3 LEDs 2SP
2 switching points, 3 LEDs and signal suppression up to 30 °C [86 °F] 2SPSU
Plug
03 M12x1, 4-pole round plug-in connection M12x1
2-pole rectangular plug-in connection, design A as per EN 175301-803 EN 175301-803
01 02 03
WE
Material numbers for electronic switching elements
Material no. Type Signal Switching points Plug LEDs
R928028409 WE-1SP-M12x1 Changeover 1
M12x1
0
R928028410 WE-2SP-M12x1 Normally open (at 75%)/
normally closed contact
(at 100%)
2 3
R928028411 WE-2SPSU-M12x1
R928036318 WE-1SP-EN175301-803 Normally closed contact 1 EN 175301-803 0
Mating connectors (max. admissible voltage: 50 V)
Mating connector fitting M12x1,
4-pole K24 with screw connection, Pg9 cable gland.
Material no. R900031155
For electronic switching element with M12x1 round plug-in connection
Mating connector fitting M12x1,
4-pole K24-3m with potted-in PVC cable, 3 m long.
Line cross-section: 4 x 0.34 mm
2
Core marking: 1 brown 2 white
3 blue 4 black
Material no. R900064381
For more round plug-in connections, see data sheet 08006.
Order example:
Inline filter with mechanical visual maintenance indicator for p
nom
= 350 bar [5,079 psi] with bypass valve, size 0100,
with 10 μm filter element and M12x1 electronic switching element with 1 switching point for HLP mineral oil hydrau-
lic fluid as per DIN 51524.
Filter with mech. visual maintenance indicator:
Electronic switching element:
Mating connector:
350LEN0100-H10XLA00-V5.0-M-R4
WE-1SP-M12x1
Mating connector fitting M12x1,
4-pole K24
Material no. R928033538
Material no. R928028409
Material no. R900031155

















6/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Inline filter
with bypass
and mechanical indicator
Inline filter,
no bypass,
with mechanical indicator
Symbols
Electronic switching element
for maintenance indicator
WE-1SP-M12x1
WE-1SP-EN175301-803
Switching element Plug
Switching
point 100 %
LED red
Switching
point 75 %
LED yellow
Stand-by
LED
green
30 °C/20 °C
[86°F/68°F]
on / off
WE-2SPSU-M12x1
Circuit diagram drawn in plugged condi-
tion at temperature > 30 °C [86 °F]
(operating state)
WE-2SP-M12x1
Circuit diagram drawn in plugged
condition (operating state)
Switching element Plug
Switching
point 100 %
LED red
Switching
point 75 %
LED yellow
Stand-by
LED green
Switching element
Switching element
Plug
Plug
Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 7/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Function, cross-section
The 350LE(N) inline filter is designed for direct installation
into pressure lines.
It consists primarily of a filter head (1), a threaded filter
bowl (2), a filter element (3) and a mechanical optical
maintenance indicator (4). For filters with low collapse
filter elements (= pressure differential code letter A), a
bypass valve (5) comes standard.
The fluid passes through the inlet to the filter element,
where it is cleaned. Any dirt particles filtered out collect in
the filter element. The filtered fluid then enters the hydrau-
lic circuit through the outlet.
The filter housing and all connection elements are
designed so that pressure spikes — as they may occur, e.g.,
due to an accelerated fluid quantity from large control
valves opening abruptly — can be safely absorbed. Sizes
0160 and larger come with a drain screw (6) standard.
Size 1000 comes with a two-part filter bowl, with the filter
bowl fixed to prevent the bowl from spinning in
the filter head.
An electronic switching element (7) can be added
to the mechanical optical maintenance indicator in order
to integrate it into an electric circuit. The electronic
switching element must be attached to the mechanical
visual maintenance indicator and held with the locking ring
supplied. The electronic switching elements are connected
with a mating connector or cable connection.
The electronic switching element must be ordered
separately.
InletOutlet
WARNING
If the maintenance indicator is ignored when an
element change is required, there is the possibility the
filter will go into bypass and contaminated oil will pass
to the clean side of the filter outlet. Therefore the
filtration effectiveness is no longer guaranteed.
8/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Technical data
(Please consult us for applications outside these parameters)
General
Installation position Vertical
Ambient temperature range °C [°F] -10 to +65 [14 to 149] (down to -30 [-22] for brief periods)
Storage conditions NBR/EPDM seal °C [°F] -40 to 65 [-40 to 149]; max. relative air humidity: 65%
FKM seal °C [°F] -20 to 65 [-4 to 149]; max. relative air humidity: 65%
Weight Filter Size 0040 0063 0100 0130 0150
kg [lbs] 4.4 [9.7] 5.0 [11.1 ] 5.9 [13.0] 10.5 [23.2 ] 11.2 [24.8 ]
Size 0160 0250 0400 0630 1000
kg [lbs] 17.2 [30.0 ] 19.5 [43.1] 23.0 [50.8] 45.0 [99.5] 93.0 [205.6]
Filter bowl Size 0040 0063 0100 0160
kg [lbs] 1.3 [2.9] 1.3 [2.9] 2.1 [4.6] 5.5 [12.1]
Size 0250 0400 0630 1000
kg [lbs] 8.0 [17.6] 12.2 [26.9] 21.4 [47.2]
Filter pipe
1)
End cap
45.3 [99.8]
2.0 [4.4]
Flow Size 0040 0063 0100 0130 0150
l [US gal] 0.3 [0.1] 0.4 [0.1] 0.5 [0.1] 0.9 [0.2] 1.1 [0.3]
Size 0160 0250 0400 0630 1000
l [US gal] 1.3 [0.3] 1.9 [0.5] 3.0 [0.8] 4.5 [1.2] 6.5 [1.7]
Material Filter head Ductile iron
Filter bowl Steel
Bypass valve Aluminum/steel/POM
Seals NBR or FKM
Visual maintenance indicator Brass
Electronic switching element Nylon 6 plastic
Hydraulics
Max. operating pressure bar [psi] 350 [5,079]
Hydraulic fluid temperature range °C [°F] -10 to 100 [14 to 212] (down to -30 [-22] for brief periods)
Min. medium conductivity pS/m 300
Fatigue strength as per ISO 10771 load cycles > 10
6
at max. operating pressure
Maintenance indicator pressure measurement type Pressure differential
Assignment: Maintenance indicator response pressure/
bypass valve cracking pressure
Maintenance indicator
response pressure
Bypass valve cracking pressure
bar [psi] 2.2 ± 0.3 [31.9 ± 4.4] 3.5 ± 0.35 [50.8 ± 5.1]
bar [psi] 5.0 ± 0.5 [72.5 ± 7.3] 7.0 ± 0.5 [101.5 ± 7.3]
bar [psi] 8.0 ± 0.8 [116 ± 11.6] No bypass valve
Direction of filtration From the outside to the inside
1)
This weight is not relevant to changing the filter element,
since only the cap has to be unscrewed.
Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 9/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Electrical (electronic switching element)
Electrical connection M12x1, 4-pole round plug-in connection EN 175301-803
standard connection
Version WE-1SP-
M12x1
WE-2SP-
M12x1
WE-2SPSU-
M12x1
WE-1SP-EN175301-803
Contact load, DC voltage A
max.
1
Voltage range V
max.
150 (AC/DC) 10 – 30 (DC) 250 (AC) / 200 (DC)
Max. switching power with resistive load W 20 70
Switching type 75% signal Normally open contact
100% signal Changeover Normally closed contact Normally closed contact
2SPSU Signal inter-
connection at
30 °C [86 °F],
return switch-
ing at 20 °C
[68 °F]
LED indicators in 2SP electronic switching elements Stand-by (LED green)
75% switching point
(LED yellow)
100% switching point
(LED red)
IP rating as per EN 60529 IP 67 65
Ambient temperature range °C [°F] -25 to 85 [-13 to 185]
Include spark extinguishing for DC voltage above 24 V to protect the switching contacts.
Weight Electronic switching element kg [lbs] 0.1 [0.22]
Technical data
(Please consult us for applications outside these parameters)
Filter element
H-series XL glass fiber material Inorganic fiber-based single-use element
Filtration ratio as per ISO 16889
up to Δp = 5 bar [72.5 psi]
Best oil cleanliness as per
ISO 4406 [SAE-AS 4059]
H20XL β
20
(c) ≥ 200 19/16/12 – 22/17/14
H10XL β
10
(c) ≥ 200 17/14/10 – 21/16/13
H6XL β
6
(c) ≥ 200 15/12/10 – 19/14/11
H3XL β
5
(c) ≥ 200 13/10/8 – 17/13/10
Admissible pressure differential A bar [psi] 30 [435]
B bar [psi] 330 [4,785]
For detailed information on Rexroth filter elements, see data sheet 51420.
10/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Compatibility with permitted hydraulic fluids
Hydraulic fluid Classification Suitable sealing materi-
als
Suitable adhesive Standards
Mineral oil HLP NBR
Standard
DIN 51524
Biodegradable Water insoluble HETG NBR
VDMA24568
HEES FKM
Water soluble HEPG FKM VDMA24568
Flame-resistant Waterless HFDU, HFDR FKM VDMA 24317
Aqueous HFAS NBR
DIN 24320
HFAE NBR
HFC NBR VDMA 24317
Skydrol EPDM Special “H”
Important information on hydraulic fluids:
For more information and data on the use of other hydraulic
fluids, see data sheet 90220 or contact us.
Flame-resistant, aqueous: Due to possible chemical reactions with
materials or machine and system component surface coating, the
service life with these hydraulic fluids may be less than expected.
Do not use filter materials made of filter paper P, use filter
elements with glass fiber filter material instead.
Biodegradable: If filter materials made of filter paper are used,
the filter life may be shorter than expected due to material
incompatibility and swelling.









  












 












 




 












 






  












 















 




















 








Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 11/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Characteristic curves H3XL
(Measured with HLP46 mineral oil as per ISO 3968)
Use our “Bosch Rexroth FilterSelect” online design software
to select the ideal filter.
Oil viscosity:
Spec. weight: < 0.9 kg/dm
3
Δp–Q characteristic curves for complete filters
Recommended initial Δp for design = 1.5 bar [21.76 psi]
Pressure differential in bar [psi]
Pressure differential in bar [psi]Pressure differential in bar [psi]
Pressure differential in bar [psi]Pressure differential in bar [psi]
Pressure differential in bar [psi]
Flow in l/min [US gpm] Flow in l/min [US gpm]
Flow in l/min [US gpm] Flow in l/min [US gpm]
Flow in l/min [US gpm] Flow in l/min [US gpm]
350LEN0040-H3XL 350LEN0063-H3XL
350LEN0100-H3XL 350LE0130-H3XL
350LE0150-H3XL 350LEN0160-H3XL









 











 



 
 











 



 




 











 



 
 











 






12/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Characteristic curves H3XL
(Measured with HLP46 mineral oil as per ISO 3968)
Use our “Bosch Rexroth FilterSelect” online design software
to select the ideal filter.
Oil viscosity:
Spec. weight: < 0.9 kg/dm
3
Δp–Q characteristic curves for complete filters
Recommended initial Δp for design = 1.5 bar [21.76 psi]
Pressure differential in bar [psi]
Pressure differential in bar [psi]Pressure differential in bar [psi]
Pressure differential in bar [psi]
Flow in l/min [US gpm] Flow in l/min [US gpm]
Flow in l/min [US gpm] Flow in l/min [US gpm]
350LEN0250-H3XL 350LEN0400-H3XL
350LEN0630-H3XL 350LEN1000-H3XL






















 








 












 




  












  












 












 




 












 






Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 13/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Characteristic curves H10XL
(Measured with HLP46 mineral oil as per ISO 3968)
Use our “Bosch Rexroth FilterSelect” online design software
to select the ideal filter.
Oil viscosity:
Spec. weight: < 0.9 kg/dm
3
Δp–Q characteristic curves for complete filters
Recommended initial Δp for design = 1.5 bar [21.76 psi]
Flow in l/min [US gpm] Flow in l/min [US gpm]
Pressure differential in bar [psi]
Pressure differential in bar [psi]Pressure differential in bar [psi]
Pressure differential in bar [psi]Pressure differential in bar [psi]
Pressure differential in bar [psi]
Flow in l/min [US gpm] Flow in l/min [US gpm]
Flow in l/min [US gpm] Flow in l/min [US gpm]
350LE0150-H10XL 350LEN0160-H10XL
350LEN0040-H10XL 350LEN0063-H10XL
350LEN0100-H10XL 350LE0130-H10XL









 











 



 
 











 



 
 











 



 












 



 
 
14/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Characteristic curves H10XL
(Measured with HLP46 mineral oil as per ISO 3968)
Use our “Bosch Rexroth FilterSelect” online design software
to select the ideal filter.
Oil viscosity:
Spec. weight: < 0.9 kg/dm
3
Δp–Q characteristic curves for complete filters
Recommended initial Δp for design = 1.5 bar [21.76 psi]
Pressure differential in bar [psi]
Pressure differential in bar [psi]Pressure differential in bar [psi]
Pressure differential in bar [psi]
Flow in l/min [US gpm] Flow in l/min [US gpm]
Flow in l/min [US gpm] Flow in l/min [US gpm]
350LEN0250-H10XL 350LEN0400-H10XL
350LEN0630-H10XL 350LEN1000-H10XL



























Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 15/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Dimensions: 350LE(N) sizes 0040 to 1000
(Dimensions in mm [inch])
Sizes 0040 to 0150Sizes 0040 to 0400
Sizes 0630 to 1000
Sizes 0160 to 1000Size 1000
Inlet
Sizes 0040 to 0630
1)
Servicing height for changing filter element
2)
Dimension B1 is reduced by 4mm [0.16 in] for SAE flanges
Type
350...
ØB5
ØB6
ØB7
ØB8
B9
C1 connection
C3
C4
SW
R…
(ISO 228)
ØC2 U…
(SAE J1926)
ØC2 S…
(SAE flanges)
LEN0040
64
[2.52]
85
[3.35]
47
[1.85]
32
[1.26]
G1/2
28
[1.10]
SAE 10"
7/8-14 UNF-2B
34
[1.34]
M6
8
[0.31]
32
[1.26]
LEN0063
G1
41
[1.61]
SAE 12"
1 1/16-12 UN-2B
LEN0100
LE0130
92
[3.62]
118
[4.65]
G1 1/4
51
[2.01]
SAE 20"
1 5/8-12 UN-2B
58
[2.28]
LE0150
LEN0160
114
[4.49]
140
[5.51]
32
[1.26]
G1 1/2
56
[2.20]
SAE 24"
1 7/8-12 UN-2B
65
[2.56]
SAE 1 1/2" 6,000
psi
M8
12
[0.47]
LEN0250
LEN0400
LEN0630
140
[5.51]
185
[7.28]
10
[0.39]
G2
72
[2.83]
SAE 2"
6,000 psi
M12
41
[1.61]
LEN1000
190
[7.48]
Type
350...
A1 A2 A3
1)
A4 A5 A6 A7 B1
2)
B2 B3 ØB4
LEN0040 203 [7.99]
115
[4.53]
80 [3.15]
158 [6.22]
25
[0.98]
167
[6.57]
20
[0.79]
92
[3.62]
65
[2.56]
30
[1.18]
LEN0063 266 [10.47] 221 [8.70]
LEN0100 356 [14.02] 311 [12.24]
LE0130 328 [12.91]
150
[5.91]
140 [5.51]
273 [10.75]
40
[1.57]
202
[7.95]
15
[0.59]
132
[5.20]
80
[3.15]
LE0150 364 [14.33] 324 [12.76]
LEN0160 322 [12.68]
170
[6.69]
262 [10.31]
50
[1.97]
222
[8.74]
10
[0.39]
164
[6.46]
70
[2.76]
LEN0250 412 [16.22] 352 [13.86]
LEN0400 562 [22.13] 502 [19.76]
LEN0630 605 [23.82]
210
[8.27]
160 [6.30] 540 [21.26]
60
[2.36]
262
[10.31]
5
[0.20]
204
[8.03]
30
[1.18]
50
[1.97]
40
[1.57]
LEN1000 843 [33.19] 650 [25.59] 778 [30.63]






































16/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Maintenance indicator
(Dimensions in mm [inch])
Pressure differential indicator with mounted
M12x1 switching element
Pressure differential indicator with mounted
EN 175301-803 switching element
1 Mechanical optical maintenance indicator;
max. tightening torque M
A max
= 50 Nm [36.88 lb-ft]
2 Switching element with locking ring for
electrical maintenance indicator (rotatable 360°);
M12x1, 4-pole round plug-in connection
3 Switching element with locking ring for electrical
maintenance indicator (rotatable 360°);
EN 175301-803 rectangular plug-in connection
4 Housing with three LEDs: 24V =
green: Stand-by
yellow: Switching point 75%
red: Switching point 100%
5 Visual indicator with memory function
6 16x1 DIN 471 locking ring,
Material no. R900003923
7 Name plate
Important:
Illustration includes a mechanical visual maintenance
indicator(1) and electronic switching element (2), (3).
Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 17/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Spare parts ordering codes
Filter element
01 Design 2.
Size
02 LEN...
(Filter element as per DIN 24550)
0040
0063
0100
0160
0250
0400
0630
1000
LE...
(Filter elements as per Bosch Rexroth standard)
0130
0150
Filter rating in µm
03 Absolute
(ISO 16889; β
x(c)
≥ 200)
Glass fiber material, not cleanable H3XL
H6XL
H10XL
H20XL
Nominal Stainless steel wire mesh, cleanable G10
G25
G40
G60
G100
Pressure differential
04 Max. admissible filter element pressure differential: 30bar [435psi], filter with bypass valve A
Max. admissible filter element pressure differential: 330bar [4,786psi], filter has no bypass valve B
Element design
05 Standard adhesive with galvanized steel 00
Special adhesive with stainless steel HV
1)
Bypass valve
06 Without bypass valve 0
Seal
07 NBR seal M
FKM seal V
EPDM seal E
01 02 03 04 05 06 07
2. 0
Filter element
Order example:
2.0100 H10XL-A00-0-M
Material no. R928006755
For detailed information on Rexroth filter elements, see data sheet 51420.
1)
Only with FKM or EPDM seal
18/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Spare parts ordering codes
01 Maintenance indicator W
02 Mechanical visual indicator O
Version
03 Pressure differential, modular design D01
Switching pressure
04 2.2bar [32psi] 2.2
5.0bar [72.5psi] 5.0
Seal
05 EPDM seal E
1)
NBR seal M
FKM seal V
Max. operating pressure
06 Switching pressure of 2.2 bar [31.9 psi]: 160 bar [2,320 psi] 160
Switching pressure of 5.0 bar [72.5 psi]: 450 bar [6,527 psi] 450
Switching pressure of 8.0 bar [116 psi]: 450 bar [6,527 psi] 450
01 02 03 04 05 06
W O D01
Mechanical visual maintenance indicator
Mechanical visual maintenance indicator
Material no. Description
R928038785 WO-D01-8.0-M-450
R901025313 WO-D01-5.0-M-450
R901025312 WO-D01-2.2-M-160
R928038784 WO-D01-8.0-V-450
R901066235 WO-D01-5.0-V-450
R901066233 WO-D01-2.2-V-160
R928054248 WO-D01-5.0-E-450
Filter element
Preferred replacement filter element program
3-micron replacement filter element 6-micron replacement filter element 10-micron replacement filter element
R928006645 2.0040 H3XL-A00-0-M R928006646 2.0040 H6XL-A00-0-M R928006647 2.0040 H10XL-A00-0-M
R928006699 2.0063 H3XL-A00-0-M R928006700 2.0063 H6XL-A00-0-M R928006701 2.0063 H10XL-A00-0-M
R928006753 2.0100 H3XL-A00-0-M R928006754 2.0100 H6XL-A00-0-M R928006755 2.0100 H10XL-A00-0-M
R928006807 2.0160 H3XL-A00-0-M R928006808 2.0160 H6XL-A00-0-M R928006809 2.0160 H10XL-A00-0-M
R928006861 2.0250 H3XL-A00-0-M R928006862 2.0250 H6XL-A00-0-M R928006863 2.0250 H10XL-A00-0-M
R928006915 2.0400 H3XL-A00-0-M R928006916 2.0400 H6XL-A00-0-M R928006917 2.0400 H10XL-A00-0-M
R928006969 2.0630 H3XL-A00-0-M R928006970 2.0630 H6XL-A00-0-M R928006971 2.0630 H10XL-A00-0-M
R928007023 2.1000 H3XL-A00-0-M R928007024 2.1000 H6XL-A00-0-M R928007025 2.1000 H10XL-A00-0-M
1)
Only with a switching pressure of 5.0 bar
Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 19/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Spare parts ordering codes
Material no. Description
R928028527 D350/445LEN0040-0100-M
R928028530 D350LE0130-0150-M
R928028532 D350/445LEN0160-0400-M
R928028536 D350/445LEN0630-M
R928028537 D350/445LEN1000-M
R928028528 D350/445LEN0040-0100-V
R928028531 D350LE0130-0150-V
R928028533 D350/445LEN0160-0400-V
R928028529 D350/445LEN0630-V
R928028534 D350/445LEN1000-V
R961010717 D350/445LEN0040-0100-E
R961010716 D350LE0130-0150-E
R961010715 D350/445LEN0160-0400-E
R961010714 D350/445LEN0630-E
R961010713 D350/445LEN1000-E
01 Seal kit D
02 Series 350/445LE
Size
03 Sizes 0040-0100 N0040-0100
Sizes 0130-0150 0130-0150
Sizes 0160-0400 N0160-0400
Size 0630 N0630
Size 1000 N1000
Seal
04 NBR seal M
FKM seal V
EPDM seal E
01 02 03 04
D 350/445LE
Seal kit
Seal kit
20/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Assembly, commissioning, maintenance
Assembly
The max. operating pressure of the system cannot
exceed the max. admissible operating pressure
of the filter (see name plate).
When assembling the filter (see also “Tightening
torques”), note the flow direction (arrows) and the
required servicing height of the filter element
(see “Dimensions”).
Filter element exchange is made easiest when the filter
bowl is oriented downward. Ensure the maintenance
indicator is easily visible.
Remove the plastic plugs in the filter inlet and outlet.
Make sure power is disconnected during assembly.
The optional electrical maintenance indicator is con-
nected using the electronic switching element with
1 or 2 switching points, which is placed on the mechan-
ical visual maintenance indicator and held in place
by a locking ring.
Commissioning
Commission the system.
Important:
The filter has no bleeding mechanism.
Maintenance
If the red indicator pin rises out of the mechanical
visual maintenance indicator and/or the electronic
switching element switches at operating temperature,
the filter element is dirty and has to be replaced/
cleaned. For more details, see data sheet 51420.
The material number of the correct replacement filter
element is on the name plate of the complete filter. Verify
that it matches the material number on the filter element.
Decommission the system.
Release operating pressure on the system side.
Important:
The filter has no bleeding mechanism.
Drain the oil on the dirt side using the drain screw
(size 0160 and larger).
Unscrew the filter bowl (or base if size 1000).
Slightly turn the filter element to remove it
from the spigot.
Clean the filter components as needed.
Check the seals on the filter bowl for damage and
replace them as needed.
For compatible seal kits, see “Spare parts”.
Wire mesh filter elements can be cleaned. For detailed
cleaning instructions, see data sheet 51420.
Slightly turn the new or cleaned filter element to install
it on the spigot.
Assembly is reverse of removal.
Note the torque specifications (“Tightening torques”).
Commission the system.
Important:
Only trained specialists may work on the filter.
The safety and functionality of the filter are only guar-
anteed with original Bosch Rexroth spare parts.
The warranty will be void if the delivery item is
modified or improperly mounted, installed, main-
tained, repaired or used by the ordering party or a
third party, or exposed to environmental conditions
exceeding our installation conditions.
WARNING
Only install or remove when system is not pressurized.
Filter is pressurized.
Only remove filter bowl when it is not pressurized.
Do not replace maintenance indicator when filter
is pressurized.
Failure to observe flow of direction during assembly
will cause filter element to be damaged beyond repair.
Particles will enter the system and damage down-
stream components.
Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 21/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Tightening torques
Mounting
Series 350... LEN0040 LEN0063 LEN0100 LE0130 LE0150 LEN0160 LEN0250 LEN0400 LEN0630 LEN1000
Screw/tightening torque
when μ
total
= 0.14
Nm [lb-ft]
M6/4.5 [3.3]
± 10%
M8/10.5 [7.7]
± 10%
M12/37 [27.3]
± 10%
Quantity 4
Recommended screw
property class
8.8
Min. screw-in depth mm [inch] 6 [0.24] + 1 [0.04] 10 [0.4] + 2 [0.08]
Filter bowl and maintenance indicator
Series 350... LEN0040 LEN0063 LEN0100 LE0130 LE0150 LEN0160 LEN0250 LEN0400 LEN0630 LEN1000
Filter bowl Screw in filter bowl as far as it will go, then unscrew 1/8 to 1/2 turn
Maintenance indicator Nm [lb-ft] Max. 50 [36.9]
EN 175301-803 switching
element cubic connector
screw
Nm [lb-ft] M3/0.5 [3.7]
Classification according to the
Pressure Equipment Directive
Inline filters for hydraulic applications as per 51422 are
considered pressure holding equipment under Article1
Section 2.1.4 Pressure Equipment Directive 97/23/EC
(PED). However, under Article1 Section3.6 PED, hydraulic
filters are exempt from the PED if they are not classified
higher than Category I (Guideline1/19).
The fluids from “Compatibility with permitted hydraulic
fluids” were considered for the classification.
They do not receive a CE mark.
Zone suitability
Gas 1 2
Dust 21 22
Use in explosive areas as per Directive 94/9/EC (ATEX)
Inline filters as per 51422 are not equipment or compo-
nents in terms of Directive 94/9/EC and do not receive a
CE mark. The ignition risk analysis showed that these
inline filters do not have their own ignition sources as per
DIN EN 13463-1:2009.
According to DIN EN 60079-11:2012, electronic mainte-
nance indicators with a switching point:
WE-1SP-M12x1 R928028409
WE-1SP-EN175301-803 R928036318
are considered simple electronic operating equipment that
does not have its own voltage source. This simple elec-
tronic operating equipment may — according to
DINEN60079-14:2012 — be used in intrinsically safe
electric circuits (Ex ib) in systems without requiring
marking and certification.
Inline filters and the electronic maintenance indicators
described here can be used in the following explosive areas:
Directives and standardization


22/24 350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG, RE 51422, edition: 2015-03
Complete filter with mech. visual maintenance indicator
Use/classification Gas 2G Dust 2D
Classification Ex II 2G c IIC TX Ex II 2D c IIC TX
Medium conductivity pS/m min. 300
Dust accumulation max. 0.5 mm
Electronic switching element in intrinsically safe electric circuit
Use/classification Gas 2G Dust 2D
Classification Ex II 2G Ex ib IIB T4 Gb Ex II 2D Ex ib IIIC T100 °C Db
Admissible intrinsically safe
electric circuits
Ex ib IIC, Ex ic IIC Ex ib IIIC
Technical data Values only for intrinsically safe electric circuit
Switching voltage Vi max. 150 V AC/DC
Switching current Ii max. 1.0 A
Switching power Pi max. 1.3 W T4 T
max
40 °C 750 mW T
max
40 °C
max. 1.0 W T4 T
max
80 °C 550 mW T
max
100 °C
Surface temperature
1)
max. 100 °C
Inner capacitance Ci Negligible
Inner inductance Li Negligible
Dust accumulation max. 0.5 mm
1)
Temperature is based on the temperature of the medium in the filter and cannot exceed this value.
Possible circuit as per DIN EN 60079-14
Incidental operating equipment
Explosive area,
zone 1
Intrinsically safe
operating equipment
Ex ib
WARNING
Explosion hazard due to high temperature.
Temperature is based on temperature of medium
in hydraulic circuit and cannot exceed this value. Take
steps to make sure max. admissible ignition tempera-
ture is not exceeded in explosive area.
Make sure potential equalization is sufficient when
using 51422 inline filters in explosive areas. Ground-
ing the filter with mounting screws is recommended.
Note that paint and oxide protective coating are not
electrically conductive.
When replacing filter element, remove packaging mate-
rial from explosive area around replacement element.
Directives and standardization
Important:
Safety and functionality of the filter are only guaran-
teed with original Bosch Rexroth spare parts.
Maintenance may only be performed by specialists on
instruction of the owner in accordance with Directive
1999/92/EC Annex II Section 1.1.
Inline filter | 350LEN0040 to 1000; 350LE0130, 0150 23/24
RE 51422, edition: 2015-03, Bosch Rexroth AG
Notes
Bosch Rexroth AG, RE 51422, edition: 2015-03
24/24
350LEN0040 to 1000; 350LE0130, 0150 | Inline filter
Bosch Rexroth AG
Ketsch plant
Hardtwaldstrasse 43
68775 Ketsch, Germany
Phone +49 (0) 62 02 / 6 03-0
filter-support@boschrexroth.de
www.boschrexroth.com
© This document, as well as the data, specifications and other information
contained therein, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without our consent.
This information only serves to describe the product. It cannot be used to derive
statements concerning a certain condition or suitability for a certain application.
This information also does not release the user from exercising his/her own
judgment and conducting his/her own testing.
Our products are subject to a natural process of wear and aging.
Notes