4/28 2WFCE | Proportional directional valve
Bosch Rexroth AG, RE 29403, edition: 2017-01
Technical data
(For applications outside these parameters, please consult us!)
general
Size NG 16 25 32 40 50
Weight kg 3.5 4.6 5.8 7.9 10.5
Installation position Any
Ambient temperature range °C –30 ... +60 (NBR seals)
–20 ... +60 (FKM seals)
Maximum storage time Years 1 (if the storage conditions are observed; refer to the operating
instructions 07600-B)
Vibration resistance ▶ Sine test according to DIN EN 60068-2-6 10 ... 2000Hz / maximum of 10g / 10 cycles / 3 axes
▶ Noise test according to DIN EN 60068-2-64 20 … 2000Hz / 10g
RMS
/ 30gpeak / 30min. / 3 axes
▶ Transport shock according to DIN EN 60068-2-27
15g / 11ms / 3 axes
Maximum relative humidity (no condensation) % 95
Maximum surface temperature °C 150
MTTFd value according to EN ISO 13849 Years 75 (for further details see data sheet 08012)
hydraulic
Maximum operating pressure
▶ Port A, B bar 420
Minimum operating pressure
▶ Port A (A → B) bar 12
▶ Port B (B → A) bar 20
Maximum pilot pressure ▶ Port X bar 420
Maximum return flow pressure
▶ Port Y bar 100
Rated flow (∆p = 5 bar)
1)
) l/min 125, 160 220, 330 320, 650 500, 940 1000, 1500
Maximum pilot flow
2)
l/min 3 5 7 9 9
Leakage flow
▶ Pilot control valve (at 100bar)
cm
3
/min < 150 < 200 < 200 < 400 < 400
▶ Main stage
– Interface A1 (0V) cm
3
/min
A → B and B → A blocked in a leakage-free manner (valve in seat position)
– Interface B1 (0V) cm
3
/min Depending on ∆p, see characteristic curves on page 9 …18
– Interface G1 (4mA) cm
3
/min Depending on ∆p, see characteristic curves on page 9 …18
– Interface B1, G1
3; 4; 5)
cm
3
/min
A → B and B → A blocked in a leakage-free manner (valve in seat position)
Pilot volume ▶ Main stage
2)
cm
3
1 2.7 6.4 12.6 24.5
Direction of flow ▶ Internal pilot oil supply
– A → B A connected to X
– B → A B connected to X
▶ External pilot oil supply
– A → B Pressure in X ≥ pressure in A
– B → A Pressure in X ≥ pressure in B
Hydraulic fluid See table page 5
Viscosity range ▶ Recommended mm
2
/s 20 … 100
▶ Maximum admissible mm
2
/s 15 … 380
Hydraulic fluid temperature range (flown-through) °C -20 … +60
Maximum admissible degree of contamination of the hydraulic fluid
cleanliness class according to ISO 4406 (c)
Class 18/16/13
5)
1)
Flow for deviating ∆p:
q
x
= q
V nom
x
∆p
x
5
2)
Stepped input signal (seat position at 100%, pilot pressure
100bar)
3)
Pin 3: 0 V
4)
Internal pilot oil supply: Observe leakage flow A → X or B → X via
pilot control valve to Y (see technical data leakage flow – pilot
control valve)
5)
External pilot oil supply: Leakage flow from A or B via the pilot
control valve is avoided; a minimum leakage flow X → B is,
however, possible
6)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents
faults and simultaneously increases the life cycle of the
components.
For the selection of the filters, see www.boschrexroth.com/filter.