6/18 3DRE(M)(E) | Proportional pressure reducing valve, pilot operated
Bosch Rexroth AG, RE 29286, edition: 2014-02
Technical data
(For applications outside these parameters, please consult us!)
1)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents faults
and at the same time increases the life cycle of the components.
For the selection of the filters see www.boschrexroth.com/filter.
2)
Adjustment at the factory.
3)
For details, see page 10.
hydraulic (measured with HLP46, ϑ
oil
= 40 ±5 °C) Size 10 Size 16
Maximum operating pressure – Port P and X bar 350 315
– Port A and T bar 315 250
– Port Y bar Separately and to the tank at zero pressure
Maximum set pressure in
channel A
– Pressure rating 50 bar bar 50 50
– Pressure rating 100 bar bar 100 100
– Pressure rating 200 bar bar 200 200
– Pressure rating 250 bar bar - 250
– Pressure rating 315 bar bar 315 -
Minimum set pressure in channel A with flow, with command value zero,
see characteristic curves page 8
bar < 5 < 4
Maximum pressure limitation
(continuously adjustable)
– Pressure rating 50 bar bar Set at the factory to 70 bar
– Pressure rating 100 bar bar Set at the factory to 130 bar
– Pressure rating 200 bar bar Set at the factory to 230 bar
– Pressure rating 250 bar (onlysize 16) bar Set at the factory to 270 bar
– Pressure rating 315 bar (onlysize 10) bar Set at the factory to 350 bar
Maximum admissible flow l/min 125 300
Pilot flow l/min 1.1
Hydraulic fluid See table page 7
Hydraulic fluid temperature range °C –20 to +80
Viscosity range mm
2
/s 15 to 380
Maximum admissible degree of contamination of the hydraulic fluid,
cleanliness class according to ISO 4406 (c)
Class 20/18/15
1)
Hysteresis % ±3 of the maximum set pressure
Repetition accuracy % < ±2 of the maximum set pressure
Linearity % ±3.5 of the maximum set pressure
Manufacturing tolerance of the
command value pressure cha-
racteristic curve, related to the
hysteresis characteristic curve;
pressure increasing
– Type 3DRE(M)
3)
– Type 3DRE(M)E
2)
at 20 % of the
command value
% < ±1.5 of the maximum set pressure
– Type 3DRE(M)
3)
– Type 3DRE(M)E
2)
at 100 % of the
command value
% < ±5 of the maximum set pressure
% < ±1.5 of the maximum set pressure
Step response T
u
+ T
g
Command value 10 % → 90 % ms < 140; measured with standing hydraulic fluid column,
1.0liters at port A
general Size 10 Size 16
Weight – Type 3DRE and 3DREM kg 7.5 10.3
– Type 3DREE and 3DREME kg 7.6 10.4
Installation position Any, preferably horizontal
Storage temperature range °C –20 to +80
Ambient temperature
range
– Type 3DRE and 3DREM °C –20 to +70
– Type 3DREE and 3DREME °C –20 to +50