2- and 3-way high response
cartridge valves
Types .WRC.../S; .WRCE.../S
Nominal sizes 63 to 160
Component series 1X
Maximum operating pressure 420 bar
Maximum flow 50000 L/min
RE 29135/02.16
Replaces: 06.13
Overview of contents Features
High response control valve of cartridge design
Controlled by means of a servo directional valve
Feedback of the control spool position by means of an
inductive positional transducer
2-way control element of poppet design
3-way control element of spool design
Typical applications,
Open or closed loop control of large flows, e.g.:
• Forging manipulators
• Press cylinders
• Pressure casting machines
Control electronics:
Integrated or to component type separate order,
see page 11
For further information regarding pilot operated valves and exter-
nal control electronics see:
• Servo directional valves NS6 Data sheet 29564
• Servo directional valves NS10 Data sheet 29583
• Servo directional valves NS16 Data sheet 29591
• Amplifier type VT-SR... Data sheet 29931
Contents Page
Features 1
Ordering details: Types 2WRC. and 3WRC.
1)
2
Symbols 3
Design, function, section 4, 5
Technical data, control electronics 6 to 9
Electrical connections, plug-in connectors 9, 10
Electronics (block circuit diagram/pin allocation) 11
Characteristic curves 12
Unit dimensions 13 to 17
Installation dimensions 18, 19
Type 3WRCE...-1X/SType 2WRCE...-1X/S
HAD 6869/01HAD 6870/01
1)
Not for new applications!
Inhalt
Overview of contents 1
Features 1
Ordering details: type 2WRC(E) 2
Ordering details: type 3WRC(E) – Not for new applications! 2
Symbols 3
Design, function and section: type 2WRC(E) 4
Design, function and section: type 3WRC(E)
1) 5
Technical data: type 2WRC(E) (for applications outside these
parameters, please consult us!) 6
Technical data: type 2WRC(E) (for applications outside these
parameters, please consult us!) 7
Technical data: type 3WRC(E)
1)
(for applications outside these para-
meters, please consult us!) 8
Technical data: type 3WRC(E)
1)
(for applications outside these para-
meters, please consult us
!) 9
Electrical connections 9
Electrical connection, plug-in connector for the integrated elec-
tronics or main stage
of the external control electronics 10
Plug-in connector for pilot control valve NS6 (NS63) 10
Plug-in connector for pilot control valves NS10 and 16 (NS80,
100, 125, 160) 10
Integrated electronics (OBE) type VT13037 for valve type
.WRCE 11
External control electronics 11
Characteristic curves (measured with HLP32
ϑ
oil
= 40 °C ±5
°C) 12
Unit dimensions: 2WRC(E) and 3WRC(E)
1)
, NS63 (nominal
dimensions in mm) 13
Unit dimensions: 2WRC(E) and 3WRC(E)
1)
, NS80 (nominal
dimensions in mm) 14
Unit dimensions: 2WRC(E) and 3WRC(E)
1)
, NS100 (nominal
dimensions in mm) 15
Unit dimensions: 2WRC(E), NS125 (nominal dimensions in mm)
16
Unit dimensions: 2WRC(E), NS160 (nominal dimensions in mm)
17
Installation dimensions to DIN ISO 7368 – except for NS125
and 160
(nom. dimensions in
mm) 18
Installation dimensions to DIN ISO 7368 – except for NS125
and 160
(nom. dimensions in mm) 19
Notes 20
2/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
Ordering details: type 2WRC(E)
2/2-way directional valve = 2
Electrically operated high response
cartridge valve
= WRC
For external control electronics = No code
With integrated electonics (OBE) = E
Nominal size 63 = 63
Nominal size 80 = 80
Nominal size 100 = 100
Nominal size 125 = 125
Nominal size 160 = 160
Designation of the spool characteristic curves
2-way function
Spool with:
– Standard poppet seat (linear) = K001
– Dual gain flow (linear fine control range) = D001
– Control window (progressive fine control range) = S001
Further details in clear text
Seal material
M = NBR seal
(suitable for mineral oil HL and HLP
to DIN 51524)
V = FKM seals
Supply voltage
No code
= For .WRC
(external control electronics)
for .WRCE:
G24
= Supply voltage +24 VDC
G15
= Supply voltage +15 VDC
Pilot valve
S = Servo directional valve
1X = Component series 10 to 19
(10 to 19 unchanged installation and connection dimensions)
2 WRC 1X S
*
3/2-way directional valve
= 3
Electrically operated high response
control valve for manifold mounting
= WRC
For external control electronics = No code
With integrated electronics (OBE) = E
Nominal size 63 = 63
Nominal size 80 = 80
Nominal size 100 = 100
Designation of the spool characteristic curves
3-way function
Spools with:
– 0 to 0.5% positive overlap (linear) = L006
– 0 to 0.5% negative overlap
(linear fine control range) = V001
– 10% positive overlap
(linear fine control range) = E001
Further details in clear text
Seal material
M = NBR seals
(suitable for mineral oil HL and HLP
to DIN 51524)
V = FKM seals
Supply voltage
No code
= For .WRC
(external control electronics)
For .WRCE:
G24
= Supply voltage +24 VDC
G15
= Supply voltage +15 VDC
Pilot valve
S = Servo directional valve
1X = Component series 10 to 19
(10 to 19 unchanged installation and connection dimensions)
3 WRC 1X S
*
Ordering details: type 3WRC(E) – Not for new applications!
Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
3/20
Symbols
Simplified: main stage with pilot control valve Detailed: main stage with pilot control valve
2-way function
2WRC


2WRCE
with integrated electronics (OBE)
2WRCE – with integrated electronics (OBE)








3-way function (spool overlap L and V)
3WRC


3WRCE
with integrated electronics (OBE)
3WRCE – with integrated electronics (OBE)










4/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
Attention: A loss of power at the pilot control valve results
in the spool being in an undefined position (2).
For preventive measures see data sheet 29135-1
„Preferred settings on the 2WRCE“
Design, function and section: type 2WRC(E)
The valve types 2WRC(E) are 3-stage high response valves.
They control the rate and direction of a flow and are primarily
used in closed loop control circuits.
Design
They comprise of the following sub-assemblies:
A pilot control valve (1) as a 2-stage servo directional valve
(pilot)
• With a dry torque motor
• Low friction jet / flapper amplifier and
• Mechanical feedback of the spool position
A main control spool (2) for flow control
An inductive position transducer (3) whose core (4) is
attached to the spool (2) of the third stage
And integrated control electronics (5) for 2WRCE or
separate electronics for the 2WRC version.
Function
Within the integrated control electronics (OBE) the command
and actual values are compared and the pilot control valve
solenoids are controlled via a currrent proportional the closed
loop control deviation.
The pilot control valve asumes a proportional control position
and controls the flows into or from control chambers A (6) and
B (7), that actuate the main spool (2) by means of the closed
loop control valve until the system deviation is 0.
The stroke of the main spool is thus controlled in proportion
to the command value. It must be noted herethat the flow also
depends on the valve pressure drop.
Valve features
Flow can be passed through the valve from A to B or from B
to A.
The poppet spool closes or opens with a command value of
approx. 2 %. With smaller command values the valve‘s closed
loop control circuit trys to correct the spool position and there-
by presses the spool, with up to the full system pressure, onto
its seat and closes the connection leak-free.
The stated switching times are only valid for the closed loop
control range of the valve. With command value jumps from the
seat to small opening values, additional delay times occur.
The 2 % opening point (= 0.2 V) is factory pre-set. When
replacing the pilot control valve or control electronics the
opening point can be calibrated by adjusting the position
transducer (3) by using the 13A/F nut.
When carrying out an exchange no adjustments to the control
electronics and pilot control valve (= closed loop controller,
controller or control electronics), other than the zero calibration
at the position controller may be carried out.
Only the filter element can be replaced on the pilot control
valve (see data sheet „Servo directional valve“)
Due to the diameter differences in the seat area, the spools
are not pressure balanced. To compensate for the force
differences for spool „K001“ 6 %, and for spools „D001“ and
„S001“ 22 % of the system pressure is required as the control
pressure, and then by adding reserves for flow forces and
dynamics, the recommended minimum control pressure can be
obtained (see technical data).
13A/F
1)
Preferably port B should be connected
to the actuator.


Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
5/20
Attention: A loss of power at the pilot control valve results
in the spool being in an undefined position (2).
for preventative measures see data sheet 29135-1
„Preferred setting on the 3WRCE“
Design, function and section: type 3WRC(E)
1)
The valve types 3WRC(E) are 3-stage 3-way high response
valves.
They control the rate and direction of a flow and are primarily
used in closed loop control circuits.
Design
They comprise of the following sub-assemblies:
A pilot control valve (1) as a 2-stage servo directional valve
(pilot)
• With a dry torque motor
• Low friction jet / flapper amplifier and
• Mechanical feedback of the spool position
A main control spool (2) for flow control
An inductive position transducer (3) whose core (4) is
attached to the spool (2) of the third stage
And integrated control electronics (5) for 3WRCE or
separate electronics for the 3WRC version.
Function
Within the integrated or external electronics, the command and
actual values are compared, and accordingly the associated
control deviation controls, the pilot valve torque motor via a
proportional current.
The pilot control valve assumes a proprtional control position
and controls the pilot control flows in/out of the control
chambers A (6) and B (7), that controls the main spool (2) via
the closed loop circuit until the control deviation is 0.
The stroke of the main spool is thereby closed loop cont-
rolled in proportion to the command value. It has, however to
be taken into account that the flow is also dependent on the
pressure drop.
Valve features
The 0 % opening point (L006 and V001 spools) is factory
pre-set. When replacing the pilot control valve or the control
electronics the opening point can be calibrated by adjusting
the position transducer (3) by using the 13A/F nut.
When carrying out an exchange no adjustments to the control
electronics and pilot control valve (= closed loop controller,
controller or control electronics) may be carried out other than
the zero calibration at the position controller.
Only the filter element can be replaced on the pilot control
valve (see data sheet „Servo directional valves“).
13A/F
1)
Not for new applications!
2)
Please use the variant with P and A exchanged.
Please consult us!
6/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
Technical data: type 2WRC(E) (for applications outside these parameters, please consult us!)
General
Nominal size NS
63 80 100 125 160
Weight kg 56 114 198 357 635
Pilot control valve nominal size (pilot) NS 6 10 10 16 16
Installation; commissioning guidelines
Optional, preferably horizontal; to data sheet 07700
Storage temperature range –20 to +80
Ambient temperature range °C –20 to +60 for WRCE
–20 to +70 for WRC
Hydraulic (measured with HLP32,
ϑ
oil
= 40 °C ±5 °C)
Nominal size NS
63 80 100 125 160
Max. operating pressure
– Main stage, ports A, B bar 420
– Pilot control valve, port X bar 315
– Pilot control valve, port Y bar Pressure peaks <100, static <10
Min. control pressure in % of the system pressure
– For spool „K001“ % 15
– For spools „D001“ and „S001“ % 45
Nominal flow q
Vnom
–10 % at p = 5 bar
– For spool „K001“ l/min 2600 4100 6300 10100 17000
– For spool „D001“ l/min 2300 3600 5800 9200 15000
– For spool „S001“ l/min 1800 3000 5200 7800 13300
Max. flow
– For spools „K001“ and „D001“ l/min 5500 9000 14000 22000 35000
– For spool „S001“ l/min 8000 13000 20000 30000 50000
Switching time at 200 bar (315 bar)
– Stroke 50% ms 37(30) 32(25) 45(35) 50(40) 70(60)
– Stroke 100% ms 70(60) 50(40) 75(60) 90(70) 120(100)
Pilot oil flow at X and Y with a stepped form of
input signal from 0 to 100 % (315 bar)
l/min
42
135
165
320
430
Zero flow of the servo pilot stage in relationship to
pressure in line X
p
x
• 0,5
70 bar
p
x
• 1,5
70 bar
p
x
• 3,5
70 bar
Control flow cm
3
36,3 67, 9 132,5 313,4 565,5




Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
7/20
Technical data: type 2WRC(E) (for applications outside these parameters, please consult us!)
Hydraulic (measured with HLP32,
ϑ
oil
= 40 °C ±5 °C)
Nominal size NS
63 80 100 125 160
Pressure fluid Mineral oil (HL, HLP) to DIN 51524,
other pressure fluids on request
Pressure fluid temperature range °C –20 to +80; preferably +40 to +50
Viscosity range mm
2
/s 20 to 380; preferably 30 to 45
Max. permissible degree of pressure fluid contamination
Cleanliness class
to ISO 4406 (c)
– Pilot control valve Class 18/16/13
1)
– Main valve Class 20/18/15
1)
Hysteresis
% 0.5
Reversal error
% 0.2
Response sensitivity
% 0.2
Electrical
Voltage type
DC
Signal type
Analogue
Opening point calibration, see page 8
% 1
Zero point drift with a change in:
– Pressure fluid temperature %/10 K 0.3
– Control pressure in X %/100 bar 0.7
Return pressure in Y 0 to 10 % from p
x
%/bar 0.3
Valve protection to EN 60529
IP65 with mounted and fixed plug-in connector
1)
The cleanliness classes stated for the components need to
be maintained in hydraulic systems. Effective filtration pre-
vents faults and simultaneously increases the life cycle of the
components.
For the selection of the filters see
www.boschrexroth.com/filter
Control electronics
Control electronics – 2WRCE Integrated in the valve, see page 11
– 2WRC
External control electronics, see data sheet 29931
Nominal command value range for 2WRCE:
0 to +10 V
^
=
0 to 100 %
In the command value range 0 to 0.2 V
the actual value stays constant at 0.2 V.
With a slow command value change from 0.2 V to 10 V,
the actual value follows the command value within ±0.1 V.
With command value jumps greater than 10 V, then the actual
value can briefly reach valves of approx. 10.5 V.
Command value V
Actual value V
8/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
Technical data: type 3WRC(E)
1)
(for applications outside these parameters, please consult us!)
General
Nominal size NS
63 80 100
Weight kg
57 116 200
Pilot control valve nominal size (pilot) NS
6 10 10
Installation; commissioning guidelines Optional, preferably horizontal; to data sheet 07700
Storage temperature range
–20 to +80
Ambient temperature range °C
–20 to +60 to WRCE
–20 to +70 to WRC
Hydraulic (measured with HLP32,
ϑ
oil
= 40 °C ±5 °C)
Nominal size NS
63 80 100
Max. operating pressure
– Main stage, ports P, A, T bar
315
– Pilot control valve, port X bar
315
– Pilot control valve, port Y bar
Pressure peaks <100, static <10
Nominal flow q
Vnom
+10 % at p = 5 bar
– For spool „L006 l/min
1200 1850 2800
– For spool „V001“ l/min
1250 1900 2700
– For spool „E001“ l/min
118 0 1820 2750
Max. flow
– For spool L…, V…, E…, l/min
3500 5600 8500
Switching time at 200 bar (315 bar)
– Stroke 50% ms
20(17) 18(13) 25(20)
– Stroke 100% ms
37(30) 32(25) 40(35)
Pilot oil flow at X and Y with a stepped form of input
signal from 0 to 100 % (315 bar)
l/min
42
130
170
Zero flow of the servo pilot stage in relationship to
pressure in line X
p
x
• 0,5
70 bar
p
x
• 1,5
70 bar
Control flow cm
3
±18,1 ±33,9 ±66,2
Pressure fluid
Mineral oil (HL, HLP) to DIN 51524,
other pressure fluids on request
Pressure fluid temperature range °C –20 to +80; preferably +40 to +50
Viscosity range mm
2
/s 20 to 380; preferably 30 to 45
Max. permissible degree of pressure fluid contamination
Cleanliness class
to ISO 4406 (c)
– Pilot control valve Class 18/16/13
2)
– Main valve Class 20/18/15
2)
Hysteresis % 0.5
Reversal error % 0.2
Response sensitivity % 0.2
1)
Not for new applications!
2)
The cleanliness classes stated for the components need
to be maintained in hydraulic systems. Effective filtration
prevents faults and simultaneously increases the life cycle of
the components.
For the selection of the filters see
www.boschrexroth.com/filter




Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
9/20
Technical data: type 3WRC(E)
1)
(for applications outside these parameters, please consult us
!)
Electrical
Voltage type DC
Signal type Analogue
Zero calibration % 1
Zero point drift with change in:
– Pressure fluid temperature %/10 K 0.3
– Control pressure in X %/100 bar 0.7
Return pressure in Y 0 to 10 % from p
x
%/bar 0.3
Valve protection to EN 60529 IP65 with mounted and fixed plug-in connector
Nominal command value range for 3WRCE:
0 to ±10 V
^
=
0 to ±100 %
With a slow command value change from 0 V to ±10 V,
the actual value follows the command value within ±0.1 V.
With command value greater than ±10 V, then the actual value
can briefly reach values of approx. ±10.5 V.
Com. value V
Act. value V
Electrical connections
Do not connect PE when the valve is already earthed via the system.
Supply voltage: +24 VDC ±6 V; full bridge rectification with a smoothing capaciter 2200 µF; I
max
= 230 mA
±15 VDC ±0,45 V; stabilised and smoothed; I
max
= 180 mA
The command and actual values have the same polarity
D positive against E main spool for the 2WRCE opens
D positive against E main spool for the 3WRCE moves in direction P to A open
Note: Electrical signals generated via control electronics (e.g. actual valve) must not be used for switching
safety-relevant machine functions!
(Also see the European Standard „Safety requirement for fluid power systems and components –
Hydraulics“, EN 982!)
Component plug allocation with integrated electronics (OBE)
The plug-in connectors are included within the scope of supply.
2)
Without enable = SO37 ( –37 attached to the type code)
Component plug allocation Pin Allocation with a G24 supply voltage Allocation with a G15 supply voltage
2WRCE 3WRCE 2WRCE 3WRCE
Supply voltage A + 24 VDC + 15 VDC
B 0 VDC – 15 VDC
C Enable (+ 24 V)
2)
Reference to A, B
Differential com. value input D
0 ... +10 V 0 ... ±10 V 0 ... +10 V 0 ... ±10 V
E
R
e
= >100 kΩ R
e
= >100 kΩ R
e
= >100 kΩ R
e
= >100 kΩ
Actual valve F
+0,2 ... +10 V 0 ... ±10 V +0,2 ... +10 V 0 ... ±10 V
Reference is pin B Reference is pin B Reference is pin C Reference is pin C
Earth PE Connected with the valve housing Connected with the valve housing
Control electronics
Control electronics – 3WRCE Integrated in the valve, see page 11
– 3WRC
External control electronics, see data sheet 29931
1)
Not for new applications!












10/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
Electrical connection, plug-in connector for the integrated electronics or main stage
of the external control electronics
Plug-in connector (within the scope of supply)
Plug-in connector to DIN EN 175201-804
Separate order under Material No. R900021267
(plastic version)
Plug-in connector (separat order)
Plug-in connector to DIN EN 175201-804
Separate order under Material No. R9000223890
(metal version)
Plug-in connector for pilot control valve NS6 (NS63)
Plug-in connector to VG 95 328
Separate order under Material No. R900005414
Connection cable: 4 or 6 core, 0,75 mm
2
, screened
(e.g. cable type LiYCY 4 or 6 x 0.75 mm
2
),
to DIN VDE 0812
Outer diameter 5 to 8.5 mm
Plug-in connector for pilot control valves NS10 and 16 (NS80, 100, 125, 160)
Plug-in connector version K8 (external control electronics)
to VG 095 342 – separate order under
Material No. R900002460
20A/F



Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
11/20
2WRC 3WRC
Integrated electronics (OBE) type VT13037 for valve type .WRCE
2 WRCE:
Act. value +0.2 V … 10 V
3 WRCE:
Act. value ±10 V
(measurement output F
has a positive potential
against with a flow
P A)
Dither generator
Controller
Output
stage
Current
controller
2 WRCE:
Com. value 0 … +10 V
3 WRCE:
Com. value ±10 V
Servo valve
Position transducer
Supply voltage
15 V 24 V
±15 V 18 to 30 V
– 15 V 0 V
M0 18 to 30 V
Oscillator
Demodulator
Coil 1
Coil 2
Red
Blue
Brown
Black
Flow direction:
A positive signal at pin D and reference potential at pin E results in
opening P A for 3WRCE
opening A B or B A for 2WRCE
Interface Integrated electronics (OBE) Valve
Block circuit diagram / pin allocation
Red
Brown
Blue
Black
Servo valve
Position transducer
Red
Brown
Blue
Black
Servo valve
Position transducer
External control electronics
Pin alloction
















      










 
0102030405060708090 100
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
1
2
3
12/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
A p = 5 bar relates to a 100% flow value of the nominal
flow of the associated table.
Type 2 WRC.../...
(2/2-way function)
Command value in %
1 Version „K001“
(spool with standard
poppet seat)
2 Version „D001“
(spool with dual gain
flow)
3 Version „S001“
(spool with control
window)
Characteristic curves (measured with HLP32
ϑ
oil
= 40 °C ±5 °C)
Flow in %
Opening point 2%
Version "L006"
Type 3 WRC.../... (3/2-way function)
U
E
/ U
EN
in %
Pressure p
A
/ p
p
in %
Pressure-signal function
for 3WRC(E)…V and L…-
limiting and average value
characteristic curves
Stroke in %
Flow in %
Version "V001" und „E001“
Stroke in %
Flow in %
„K001“
„D001“
„S001“
For other valve pressure diffe-
rentials, the following applies:
p
p
nom
q = q
vnom





























Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
13/20
Unit dimensions: 2WRC(E) and 3WRC(E)
1)
, NS63 (nominal dimensions in mm)
2WRC(E) 63
3WRC(E) 63
1)
(the missing dimensions are
the same as the 2WRC(E) 63...)
1
Pilot control valve (servo directional valve NS6)
2
Bush
3 Plug-in connector (Material No. R900021267)
included within the scope of supply
4 Plug-in connector (Material No. R900005414)
included within the scope of supply
5
Space required to remove the plug-in connector
6
Cabling (only for WRCE)
7
Valve fixing screws
(are included within the scope of supply)
4 S.H.C.S. ISO 4762 – M30 x 220-10.9;
Tightening torque for a tightening factor of 1.6 : 1900 Nm
8
Locating pin hole
9
Identical seal rings for ports X and Y
10
Name plate
11
Test points for control pressures, screwed coupling G1/4
12
Transport aid
Required surface finish of the
valve mounting surface
1)
Not for new applications!


























14/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
Unit dimensions: 2WRC(E) and 3WRC(E)
1)
, NS80 (nominal dimensions in mm)
2WRC(E) 80
3WRC(E) 80
1)
(the missing dimensions are the same
as the 2WRC(E) 80...)
1
Pilot control valve (servo directional valve NS10)
2
Bush
3 Plug-in connector (Material No. R900021267)
included within the scope of supply
4 Plug-in connector (Material No. R900002460)
included within the scope of supply
5
Space required to remove the plug-in connector
6
Cabling (only for WRCE)
7
Valve fixing screws
(are included within the scope of supply)
8 S.H.C.S. ISO 4762 – M24 x 220-10.9;
Tightening torque for a tightening factor of 1.6 : 960 Nm
8
Locating pin hole
9
Identical seal rings for ports X and Y
10
Name plate
11
Test points for control pressure, G1/4 screwed coupling
12
Transport aid
Required surface finish of the
valve mounting surface
1)
Not for new applications!


























Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
15/20
Unit dimensions: 2WRC(E) and 3WRC(E)
1)
, NS100 (nominal dimensions in mm)
2WRC(E) 100
3WRC(E) 100
1)
(the missing dimensions are the same
as for 2WRC(E) 100...)
1
Pilot control valve (servo directional valve NS10)
2
Bush
3 Plug-in connector (Material No. R900021267)
included within the scope of supply
4 Plug-in connector (Material No. R900002460)
included within the scope of supply
5
Space required to remove the plug-in connector
6
Cabling (only for WRCE)
7
Valve fixing scews
(are included within the scope of supply)
8 S.H.C.S. ISO 4762 – M30 x 280-10.9;
Tightening torque for a tightening factor of 1.6 : 1900 Nm
8
Locating pin hole
9
Identical seal rings for ports X and Y
10
Name plate
11
Test points for control pressures,
G1/4 screwed coupling
12
Transport aid
Required surface finish of the
valve mounting surface
1)
Not for new applications!


























16/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
Unit dimensions: 2WRC(E), NS125 (nominal dimensions in mm)
2WRC(E) 125
1
Pilot control valve (servo directional valve NS16)
2
Bush
3
Plug-in connector (Material No. R900021267)
included within the scope of supply
4
Plug-in connector (Material No. R900002460)
included within the scope of supply
5
Space required to remove the plug-in connector
6
Cabling (only for WRCE)
7
Valve fixing screws
(are included within the scope of supply)
8 S.H.C.S. ISO 4762 – M36 x 300-10.9;
Tightening torque for a tightening factor of 1.6 : 3300 Nm
8
Locating pin hole
9
Identical seal rings for ports X and Y
10
Name plate
11
Test points for control pressures, G1/4 screwed coupling
12
Transport aid
Required surface finish of the
valve mounting surface
1)
Not for new applications!


























Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
17/20
Unit dimensions: 2WRC(E), NS160 (nominal dimensions in mm)
2WRC(E) 160
1
Pilot control valve (servo directional valve NS16)
2
Bush
3
Plug-in connector (Material No. R900021267)
included within the scope of material
4
Plug-in connector (Material No
. R900002460)
included within the scope of material
5
Space required to remove the plug-in connector
6
Cabling (only for WRCE)
7
Valve fixing screws
(are included within the scope of material)
12 S.H.C.S. ISO 4762 –
M42 x 420-10.9; Tightening torque for a
tightening factor of 1.6 : 5000 Nm
8
Locating pin hole
9
Identical seal rings for ports X and Y
10
Name plate
11
Test points for control pressures,
G1/4 screwed coupling
12
Transport aid
Required surface finish of the
valve mounting surface
1)
Not for new applications!





















































18/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
Installation dimensions to DIN ISO 7368 – except for NS125 and 160
(nom. dimensions in
mm)
NS63 NS80, 100
NS125 NS160
NS 63 80 100
D8
M30 M24 M30
max. ØD9
12 16 20
ØD10
8 10 10
L1
180 250 300
L2
125 200 245
L3
62,5
L4
75
L5
38
Tolerances to:
– General tolerances ISO 2768-mK
1
Locating pin hole
Counterbore for ports X and Y in the manifold, only for
NS160











































Hydraulics Bosch Rexroth AG
RE 29135/02.16 .WRC…/S; .WRCE…/S
19/20
Tolerances to:
– General tolerances ISO 2768-mK
1
Depth of fit, minimum dimensions
2
Ports P, T or B can be arranged about the centre axis of
port A. However care must be taken to ensure that the
fixing and control bores are not damaged.
NS 63 80 100 125 160
ØD1
H7
120 145 18 0 225 300
ØD2
H7
116 140 174 220 290
ØD3
H7
90 110 13 5 200 270
ØD4
63 80 100 max.150 max.200
ØD5
48 60 75 95 120
ØD6
H7
90 110 13 5 200 270
ØD7
63 80 100 125 200
H1
130 175 210 257 370
H2
155 205 245 300 425
H3
95 130 155 192 268
H4
40 40 50 40 50
H5
20 25 29 31 45
H7
85 125 155 195 245
H8
165 215 270 335 420
H9
195 245 305 380 480
H10
57 90 112 140 175
H11
137 180 225 280 350
H12
33 60 75 93 115
H13
28 25 32 37 45
H16
4 5 5 5,5 5,5
H17
4 5 5 7 8
H18
65 50 63
W
0,05 0,1 0,2 0,2 0,2
Installation dimensions to DIN ISO 7368 – except for NS125 and 160
(nom. dimensions in mm)
Cavity for type 2WRC...
to DIN ISO 7368
Cavity for type 3WRC...
y
= Rmax 8
x
= Rmax 4
z
= Rz 10
Bosch Rexroth AG
Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany
Telefon +49 (0) 93 52 / 18-0
documentation@boschrexroth.de
www.boschrexroth.de
20/20 Bosch Rexroth AG Hydraulics
.WRC…/S; .WRCE…/S
RE 29135/02.16
© This document, as well as the data, specifications and other informations
set forth in it, are the exclusive property of Bosch Rexroth AG. Without their
consent it may not be reproduced or given to third parties.
The data specified above only serves to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The details stated do not release you from the
responsibility for carrying out your own assessment and verification. It must be
remembered that our products are subject to a natural process of wear and
ageing.
Notes