VPN1 0T.F4.01 - X - Y - Z
Insert type
Hose burst
When the lowering speed exceeds preset value, as it might happen
in case of hose failure, the flow is blocked. These valves should
ideally be screwed directly into the actuator outlet port. Sealing
parts are superfinished and enable to lock the load in the position
where the actuator is in the moment of hose failure. These valves
can be supplied, on request, with an orifice on the disc, allowing
an emergency lowering of the load. It is recommended to fit a flow
regulator valve downstream the hose burst valve, at the end of the
flexible hose, to control the lowering speed at the nominal value.
The “R” gap must be adjusted to allow a flow at least 50% over the
nominal regulated flow from the actuator.
Technical data
Description
RE 18329-85/03.16
Replaces: RE 18329-85/02.16
Max. operating pressure bar (psi) 315 (4500)
Max. flow l/min. (gpm)
see performance graphs
(
‘R‘-Q
)
Fluid temperature range °C (°F) -30 to 100 (-22 to 212)
Installation torque Nm (ft-lbs) see “Dimensions” table
Weight kg (lbs) see “Dimensions” table
Special cavity see “Dimensions”
Lines bodies and standard
assemblies
Please refer to section “Hydraulic
integrated circuit” or consult
factory
Fluids
Mineral-based or synthetics
with lubricating properties at
viscosities of 10 to 500 mm
2
/s (cSt)
Recommended degree of fluid
contamination
Nominal value max. 10µm (NAS 8)
ISO 4406 19/17/14
Installation No restrictions
Other Technical Data See data sheet RE 18350-50
Note: available also as“Sleeve valve for line
mounting”
See data sheets RE 18316-85, RE 18316-86,
RE 18316-87 and RE 18316-88
The valve is only supposed to be operated in case
of hose failure. Should this circumstance occur, we
strongly recommend to verify the integrity of the
valve and eventually to replace it in the event that the
pressure spike generated by the hose failure was such
to damage permanently some valve components.
Hose burst check valve Hose burst check valve
with orifice