RE 18321-22/03.2016, Bosch Rexroth Oil Control S.p.A.
Description
Input flow at 3 will be divided and output equally to 2 and 4
independent of system pressures. Should either 2 or 4
become blocked in flow division mode, approximately 5% of
the input flow will be transmitted to the open port. Flow
combining is not permitted.
Flow divider
Common cavity, Size 10
RE 18321-22
Edition: 03.2016
Replaces: 09.2009DSDN-10A 04.05.04.00.85 - Z
Technical data
Pressure min. - max. 10 - 350 bar (145 - 5000 psi)
Flow range see “Range of total flow” table
Fluid temperature range -30 to 100 °C (-22 to 212 °F)
Installation torque 41 - 47 Nm (30 - 35 ft-lbs)
Division ratio 50% - 50%
Weight 0.28 kg (0.62 lbs)
Cavity CA-10A-4N (see data sheet 18325-70)
Lines bodies and standard
assemblies
Please refer to section “Hydraulic
integrated circuit” or consult factory
Seal kit
1)
Code: RG10A4010520100
material no: R901111371
Fluids Mineral-based or synthetics with
lubricating properties
at viscosities of 10 to 500 mm
2
/s (cSt)
Recommended degree of
fluid contamination
Nominal value max. 10µm (NAS 8) /
ISO 4406 19/17/14
Installation No restrictions
Other Technical Data See data sheet 18350-50
1) Only external seals for 10 valves
Slippage (tolerance) from theoretical divided flows: ±5% to ±10%,
depending from inlet flow (see diagram).
N.B. Slippage is lowest toward upper limit of nominal range.