RE 18321-20/03.2016, Bosch Rexroth Oil Control S.p.A.
Description
A constant flow rate, regardless of system pressures, is
established from 1 to 3 while a minimum pressure
differential of 14 bar (200 psi) exists between the two
ports. Input flow supplied to 1 in excess of the regulated
output at 3 is by-passed to 2. Output flow can be varied
from closed to the nominal maximum rating for the valve.
Flow from 3 to 1 is limited by the diameter of the selected
control orifice and is not pressure compensated. Flow from
2 to 1 is not permitted.
Flow control, 3-way pressure compensated,
combination type fully adjustable
Common cavity, Size 10
RE 18321-20
Edition: 03.2016
Replaces: 09.2009VRFD-10A 04.04.02 - X - 85 - Z
Technical data
Pressure min. - max. 14 - 350 bar (200 - 5000 psi)
Max. inlet flow 60 l/min. (16 gpm)
Flow range see “Regulated flow range” table
Fluid temperature range -30 to 100 °C (-22 to 212 °F)
Installation torque 41 - 47 Nm (30 - 35 ft-lbs)
Weight
1)
0.26 kg (0.57 lbs)
Cavity CA-10A-3N (see data sheet 18325-70)
Lines bodies and standard
assemblies
Please refer to section “Hydraulic
integrated circuit” or consult factory
Seal kit
2)
Code: RG10A3010520100
material no: R901111369
Fluids Mineral-based or synthetics with
lubricating properties
at viscosities of 10 to 500 mm
2
/s (cSt)
Recommended degree of
fluid contamination
Nominal value max. 10µm (NAS 8) /
ISO 4406 19/17/14
Installation No restrictions
Other Technical Data See data sheet 18350-50
1) Standard version X=04 type
2) Only external seals for 10 valves
Characteristic curve
Pressure
Flow
Regulated flowTurn