RE 18321-20/03.2016, Bosch Rexroth Oil Control S.p.A.
Description
A constant flow rate, regardless of system pressures, is
established from 1 to 3 while a minimum pressure
differential of 14 bar (200 psi) exists between the two
ports. Input flow supplied to 1 in excess of the regulated
output at 3 is by-passed to 2. Output flow can be varied
from closed to the nominal maximum rating for the valve.
Flow from 3 to 1 is limited by the diameter of the selected
control orifice and is not pressure compensated. Flow from
2 to 1 is not permitted.
Flow control, 3-way pressure compensated,
combination type fully adjustable
Common cavity, Size 10
RE 18321-20
Edition: 03.2016
Replaces: 09.2009VRFD-10A 04.04.02 - X - 85 - Z
Technical data
Pressure min. - max. 14 - 350 bar (200 - 5000 psi)
Max. inlet flow 60 l/min. (16 gpm)
Flow range see “Regulated flow range” table
Fluid temperature range -30 to 100 °C (-22 to 212 °F)
Installation torque 41 - 47 Nm (30 - 35 ft-lbs)
Weight
1)
0.26 kg (0.57 lbs)
Cavity CA-10A-3N (see data sheet 18325-70)
Lines bodies and standard
assemblies
Please refer to section “Hydraulic
integrated circuit” or consult factory
Seal kit
2)
Code: RG10A3010520100
material no: R901111369
Fluids Mineral-based or synthetics with
lubricating properties
at viscosities of 10 to 500 mm
2
/s (cSt)
Recommended degree of
fluid contamination
Nominal value max. 10µm (NAS 8) /
ISO 4406 19/17/14
Installation No restrictions
Other Technical Data See data sheet 18350-50
1) Standard version X=04 type
2) Only external seals for 10 valves
Characteristic curve
Pressure
Flow
Regulated flowTurn
2
Bosch Rexroth Oil Control S.p.A., RE 18321-20/03.2016
Bosch Rexroth Oil Control S.p.A.
Via Leonardo da Vinci 5
P.O. Box no. 5
41015 Nonantola – Modena, Italy
Tel. +39 059 887 611
Fax +39 059 547 848
compact-hydraulics-cv@boschrexroth.com
www.boschrexroth.com/compacthydraulics
© This document, as well as the data, specifications and other information set
forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a.. It
may not be reproduced or given to third parties without its consent. The data
specified above only serve to describe the product. No statements concerning
a certain condition or suitability for a certain application can be derived from
our information. The information given does not release the user from the
obligation of own judgment and verification. It must be remembered that our
products are subject to a natural process of wear and aging. Subject to change.
VRFD-10A | Flow control, 3-way pressure compensated
Dimensions [mm (inches)]
Ordering code
Dimensions
Handknob
Calibrated handknob
Flow control, 3-way pressure compensated
combination type fully adjustable
Series 0/A to L
unchanged performances and dimensions
Version and options standard
Regulated flow range
l/min. (gpm)
Adjustments
20 0.1-20 (0.03-5.28)
04 Handknob
40
0.2-30 (0.05-7.93)
40 Calibrated handknob
85 Common cavity, Size 10
Preferred types
04.04.02 X 85 Z 00 *
Type Material number
04040204852000A R930055365
04040204854000A R930055362
04040240852000A R930055366
04040240854000A R930055363
Type Material number