RE 18319-40/03.2016, Bosch Rexroth Oil Control S.p.A.
Technical data
Max. operating pressure 350 bar (5000 psi)
Max. flow 120 l/min. (32 gpm)
Pilot ratio 3.2:1
Max. internal leakage 5 drops/min.
Fluid temperature range -30 to 100 °C (-22 to 212 °F)
Installation torque 60 - 70 Nm (44 - 52 ft-lbs)
Weight 0.25 kg (0.55 lbs)
Cavity SUN T-2A
Lines bodies and standard
assemblies
Please refer to section “Hydraulic
integrated circuit” or consult factory
Seal kit
1)
Code: RG12U9020110100
material no: R930005599
Fluids Mineral-based or synthetics with
lubricating properties
at viscosities of 5 to 800 mm
2
/s (cSt)
Recommended degree of
fluid contamination
Nominal value max. 10µm (NAS 8) /
ISO 4406 19/17/14
Installation position No restrictions
Other Technical Data See data sheet 18350-50
1) Only external seals for 10 valves
Description
When pressure at 2 rises above the spring bias pressure, the
poppet is pushed from its seat and flow is allowed from 2 to
1. The valve is normally closed (checked) from 1 to 2. When
sufficient pilot pressure is present at port 3, the pilot piston
acts to push the poppet from its seat and flow is allowed from
1 to 2. Precision machining and hardening processes allow
virtually leak-free performance in the checked condition.
Pilot operated check,
pilot to open
SUN cavity interchange, T-2A
RE 18319-40
Edition: 03.2016
Replaces:09.2009VSON-12U 04.33.07 - X - 86 - Z
Characteristic curve
Flow Q
Pressure Δp