RE 18318-58/03.2016, Bosch Rexroth Oil Control S.p.A.
Technical data
Max. operating pressure 350 bar (5000 psi)
Max. pilot pressure 175 bar (2500 psi) for Z=02 and Z=03
250 bar (3600 psi) for Z=13
Max. flow 20 l/min (5 gpm)
Max. internal leakage
1)
50 cm
3
/min. (3 cu.in./min.)
Fluid temperature range -30 to 100 °C (-22 to 212 °F)
Installation torque 41 - 47 Nm (30 - 35 ft-lbs)
Weight 0.28 kg (0.62 lbs)
Cavity CA-10A-3N (see data sheet 18325-70)
Lines bodies and standard
assemblies
Please refer to section “Hydraulic
integrated circuit” or consult factory
Seal kit
2)
Code: RG10A3010520100
material no: R901111369
Fluids Mineral-based or synthetics with
lubricating properties
at viscosities of 10 to 500 mm
2
/s (cSt)
Recommended degree of
fluid contamination
Nominal value max. 10µm (NAS 8) /
ISO 4406 19/17/14
Installation position No restrictions
Other Technical Data See data sheet 18350-50
1) 1 - 3 to 80% of pressure setting
2) Only external seals for 10 valves
Description
When a minimum pilot pressure is applied to port PIL,
flow passes from 2 to 1. When the pressure at 1 exceeds
the pressure setting (defined by pilot pressure times pilot
ratio), the valve acts to restrict flow at 2. This increases the
pressure drop through the valve and maintains consistent
pressure at 1. Additionally, if pressure at 1 rises above the
pressure setting, flow is relieved to 3 until the setting is re-
attained.
Pressure reducing and relieving,
with pilot controlled setting
Common cavity, Size 10
RE 18318-58
Edition: 03.2016
Replaces: 01.2010VRPE-10A 04.95.07 - X - 85 - Z
Characteristic curve
Flow Q
Pressure Δp