RE 18301-25/02.2016, Bosch Rexroth AG
Intermediate elements
with check valves for emergency pump
RE 18301-25
Edition: 02.2016
Replaces: 07.2012
Description
The intermediate elements TI-00-__- are designed to be
fi tted between two directional valve elements. They are
available with check valve in (P) line, or in (T) line , or in
both (P) and (T) line.
With the check valve on (P) line, they are normally fi tted to
allow free fl ow from (P) to (P1) and prevent reverse fl ow
from (P1) to (P).
With the check valve on (T) line, they are normally fi tted to
allow free fl ow from (T1) to (T), and to prevent reverse fl ow
(T) to (T1).
Technical data
General
Weight TI-00-PT-.. kg (lbs) 0.54 (1.19)
Weight TI-00-0P-.. kg (lbs) 0.52 (1.15)
Weight TI-00-0T-.. kg (lbs) 0.52 (1.15)
Ambient Temperature °C (°F) –20....+50 (-4....+122)
(NBR seals)
Hydraulic
Maximum pressure bar (psi) 250 (3625)
Maximum inlet fl ow l/min (gpm) 50 (13.2)
Hydraulic fl uid
General properties: it must have
physical lubricating and chemical
properties suitable for use in
hydraulic systems such as, for
example:
Mineral oil based hydraulic
fl uids HL (DIN 51524 part 1).
Mineral oil based hydraulic
fl uids HLP (DIN 51524 part 2).
For use of environmentally
acceptable fl uids
(vegetable or polyglycol
base) please consult us.
Fluid Temperature °C (°F) –20....+80 (-4....+176) (NBR)
Permissible degree of
fl uid contamination
ISO 4572: β
x
≥75 X=12...15
ISO 4406: class 20/18/15
NAS 1638: class 9
Viscosity range mm
2
/s 5....420
Pressure drop through the check valves P>P1 and T1>T
bar
10
8
6
4
2
0
0 10 20 30 40 50 l/min
0 3 6 9 12 13.2gpm
psi
140
112
84
56
28
0
Pressure p
Flow Q
Note
For applications with different specifi cations consult us
TI-00-__-