RE 18301-15/06.2018, Bosch Rexroth AG
4/3 and 4/2 Proportional directional valve elements
L8581… (EDC-P1)
RE 18301-15
Edition: 06.2018
Replaces: 07.12
4/3 and 4/2 Proportional directional valve elements
with fl ow sharing control (LUDV concept)
PATENT PENDING
RE 18301-15
Edition: 06.2018
Replaces: 05.2017
General specifi cations
Valve element with direct proportional fl ow sharing
control.
It can achieve the simultaneous activation of different
actuators by distributing the available fl ow
proportionally to the speeds selected by the operator.
All simultaneous movements go on at the same
reciprocal speed also in case of fl ow shortage.
Each energized actuator receives a pressure
compensated fl ow.
No shuttle valve fi tted.
Wet pin proportional tubes for DC coils, with push rod
for mechanical override; nickel plated surface.
Manual override (push-button, screw type or lever)
available as option.
Different plug-in connectors available: see ordering
details.
Size 6
Series 00
Maximum operating pressure 310 bar (4500 psi)
Maximum ow at 14 bar (203 psi) 59 l/min (15.59 gpm)
Maximum ow at 18 bar (261 psi) 65 l/min (17.17 gpm)
Ports connections planned G 3/8 - G 1/2 - SAE8 and
Modular
Contents
Ordering details 2
Functional description 4
Technical data 5
Characteristic curves 6
External dimensions and fi ttings 8
Electric connection 10
L8581… (EDC-P1)
Bosch Rexroth AG, RE 18301-15/06.2018
2 L8581… (EDC-P1) | 4/3 and 4/2 Proportional directional valve elements
Ordering details
Ordering details
01 02 03 04 05 06 07 08 09 10
L 8 5 81 0 _ _
Family
01 Directional Valve elements ED
L
Type
02 Size 6 proportional
8
Confi guration
03 Flow Sharing
5
Coil type
04 GP45
81
Spool variants
05 4/3 operated both sides a and b; P, A, B, T closed in neutral
B2
4/2 operated on side a only; P, A, B, T closed in neutral
B3
4/2 operated on side b only; P, A, B, T closed in neutral
B4
4/3 operated on both sides a and b; P closed; A and B
to T in neutral
E2
4/2 operated on side a only; P closed; A and B to T in neutral
E3
4/2 operated on side b only; P closed; A and B to T in neutral
E4
Flow pattern & Nominal fl ow
1) - 4)
06
Both meter in and out, A 4l/min(1.06gpm) -
B 4l/min(1.06gpm)
S0
Both meter in and out, A 8l/min(1.85gpm) -
B 8l/min(1.85gpm)
S1
Both meter in and out, A 12l/min(3.17gpm) -
B 12l/min(3.17gpm)
S2
Both meter in and out, A 16l/min(4.23gpm) -
B 16l/min(4.23gpm)
S3
Both meter in and out, A 25l/min(6.6gpm) -
B 25l/min(6.6gpm)
S4
Both meter in and out, A 40l/min(10.57gpm) -
B 40l/min(10.57gpm)
S8
Both meter in and out, A 50l/min(13.2gpm) -
B 50l/min(13.2gpm)
2)
S9
Only meter in, A 8l/min(1.85gpm) - B 8l/min(1.85gpm)
I 1
Only meter in, A 12l/min(3.17gpm) -
B 12l/min(3.17gpm)
I 2
Only meter in, A 25l/min(6.6gpm) - B 25l/min(6.6gpm)
I 4
Only meter in, A 40l/min(10.57gpm) -
B 40l/min(10.57gpm)
I 8
Only meter in, A 50l/min(13.2gpm) -
B 50l/min(13.2gpm)
2)
I 9
Only meter in, A 59l/min(15.59gpm) -
B 59l/min(15.59gpm)
2)
IZ
Both meter in and out, A 4l/min(1.06gpm) -
B 8l/min(1.85gpm)
01
Both meter in and out, A 8l/min(1.85gpm) -
B 12l/min(3.17gpm)
12
Both meter in and out, A 8l/min(1.85gpm) -
B 16l/min(4.23gpm)
13
Both meter in and out, A 12l/min(3.17gpm) -
B 16l/min(4.23gpm)
23
Both meter in and out, A 12l/min(3.17gpm) -
B 25l/min(6.6gpm)
24
Both meter in and out, A 16l/min(4.23gpm) -
B 25l/min(6.6gpm)
34
Both meter in and out, A 16l/min(4.23gpm) -
B 40l/min(10.57gpm)
38
Both meter in and out, A 25l/min(6.6gpm) -
B 40l/min(10.57gpm)
48
Both meter in and out, A 25l/min(6.6gpm) -
B 50l/min(13.2gpm)
2)
49
Both meter in and out, A 40l/min(10.57gpm) -
B 50l/min(13.2gpm)
2)
89
Voltage supply 07 03 01 00
07 Without coil
–––
00
12V DC
●●●
–OB
24V DC
●●●
–OC
Electric connections
08 Without coils
00
With coils, without mating connector DIN EN 175301-803
01
6)
With coils, without mating connector vertical Amp-
Junior
03
With coils, without mating connector DT04-2P
07
Ports
09 G 3/8 DIN 3852
0
G 1/2 DIN 3852
2
3/4-16 UNF 2-B (SAE8)
3
Machined to interface modular elements
M
5)
Options
10 Without manual override
00
Push-button type manual override
0P
Screw type manual override
0F
Twist type manual override (180°)
0T
Red push-button type manual override
RP
Black push-button type manual override
NP
Lever type manual override
3)
_ _
= Available
= Not available
1) The required hydraulic layout and spool variant can be chosen by
consulting page 3.
2) With fl ow boost system. See external dimension on page 10-11.
3) Each different option for the type of emergency chosen implies a
specifi c ordering code (refer to page 8).
4) With ∆p (P > A or P > B) 14 bar (203 psi).
5) See RE18301-45, RE18301-46, RE18301-47, for fl angeable
elements.
6) For connectors ordering code see data sheet RE 18325-90.
Symbols
= 0
= 2
= 3
= M
RE 18301-15/06.2018, Bosch Rexroth AG
4/3 and 4/2 Proportional directional valve elements | L8581… (EDC-P1)
Ordering details
3
Spool variant and Flow pattern
=B2 =E2
=B2I =E2I
=B3 =E3
=B3I =E3I
=B4 =E4
=B4I =E4I
Both meter in and out
Only meter in
Bosch Rexroth AG, RE 18301-15/06.2018
4 L8581… (EDC-P1) | 4/3 and 4/2 Proportional directional valve elements
Functional description
Functional description
4
6
BA
234 77
5
1
The sandwich plate design directional valve elements
L8581… are compact direct operated pressure
compensated proportional solenoid valves which control
the start, the stop, the direction and the quantity of the oil
ow, with a FLOW SHARING principle. These elements
basically consist of a stackable housing (1) with a control
spool, two solenoids (4), two return springs. Energized by
an electronic feed regulator, each solenoid (4) displaces
the control spool from its neutral-central position “0”
proportionally to the current received. When the spool is
shifted and the metering notch is open, fl ow delivery starts
and is controlled by a 3 way pressure compensator
followed by a check valve for each port A and B. The
compensator, balanced by the LS pressure at the opposite
end, lifts up and unloads a regulated fl ow which is sent to
the A (or B) port through the relevant check valve; at the
same time the opposite port allows oil return to tank.
LS pressure reaches the compensator “dead end” directly
from the A or B port, while the check valves lock eventual
pressure oscillations which could affect the compensator
function.
When the solenoid is de-energized, the return spring
pushes the spool thrust washer back against the housing
and the spool returns in its neutral-central position.
Each coil (4) is fastened to the solenoid tube by the ring
nut (7). A pin allows to push the spool under emergency
conditions, when the solenoid cannot be energized, like in
case of voltage shortage.
RE 18301-15/06.2018, Bosch Rexroth AG
4/3 and 4/2 Proportional directional valve elements | L8581… (EDC-P1)
Technical data
5
Technical data
General
Valve element with 2 solenoids kg (lbs) 3.95 (8.71)
Valve element with 1 solenoid kg (lbs) 3.60 (7.91)
Ambient Temperature °C (°F) -30....+90 (-22....+194) (NBR seals)
MTTFd 150 years see RE 18350-51
Hydraulic
Maximum pressure at P, A and B ports bar (psi) 310 (4500)
Maximum pressure at T bar (psi) 210 (3050)
Maximum pressure with lever emergency at T bar (psi) 140 (2030)
Max. regulated fl ow at 14 bar (203 psi) l/min (gpm) 59 (15.59)
Max. regulated fl ow at 18 bar (261 psi) l/min (gpm) 65 (17.17)
E-schemes fl ow pattern symmetrical closed pass in the
neutral position (connection from A to T and B to T)
Approx. 2% of the nominal cross-section
Hydraulic fl uid
General properties: it must have physical lubricating
and chemical properties suitable for use in hydraulic
systems such as, for example:
Mineral oil based hydraulic fl uids HL (DIN 51524 part 1).
Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2).
For use of environmentally acceptable fl uids (vegetable or
polyglycol base) please consult us.
Fluid Temperature °C (°F) -30....+100 (-22....+212) (NBR seals)
Permissible degree of fl uid contamination ISO 4572: β
x
≥75 X=12...15
ISO 4406: class 20/18/15
NAS 1638: class 9
Viscosity range mm
2
/s 20....380 (optimal 30....46)
Electrical
Voltage type PWM 120 Hz
Voltage tolerance (nominal voltage) % -10 .... +10
Duty Continuous, with ambient temperature ≤ 90°C (194°F)
Coil wire temperature not to be exceeded °C (°F) 180 (356)
Insulation class H
Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC
Coil weight kg (lbs) 0.335 (0.739)
Voltage V 12 24
Nominal 100% current A 1.8 1.2
Coil resistance
(nominal at 20°C (68°F))
- Cold value Ω 3.3 7.2
Note
For applications with different specifi cations consult us
Code Voltage [V] Connector type Coil description Marking Coil Mat no.
=OB 01
12 DC EN 175301-803 (Ex. DIN 43650) GP45 01 - 45 K4 12 DC R901022180
=OB 03
12 DC AMP JUNIOR GP45 03 - 45 C4 12 DC R901022680
=OB 07
12 DC DEUTSCH DT 04-2P GP45 07 - 45 K40 12 DC R901272648
=OC 01
24 DC EN 175301-803 (Ex. DIN 43650) GP45 01 - 45 K4 24 DC R901022174
=OC 03
24 DC AMP JUNIOR GP45 03 - 45 C4 24 DC R901022683
=OC 07
24 DC DEUTSCH DT 04-2P GP45 07 - 45 K40 24 DC R901272647
Bosch Rexroth AG, RE 18301-15/06.2018
6 L8581… (EDC-P1) | 4/3 and 4/2 Proportional directional valve elements
Characteristic curves
Characteristic curves
Characteristic curves Q=Q (I)
0 20 40 60 80 100%A
0 20 40 60 80 100%A
0 20 40 60 80 100%A 0 20 40 60 80 100%A
0 20 40 60 80 100%A
0 20 40 60 80 100%A
0 20 40 60 80 100%A
l/min
6
5
4
3
2
1
0
l/min
30
25
20
15
10
5
0
l/min
60
50
40
30
20
10
0
l/min
78
65
52
39
26
13
0
l/min
24
20
16
12
8
4
0
l/min
18
15
12
9
6
3
0
l/min
60
50
40
30
20
10
0
gpm
1.6
1.5
1.2
0.9
0.6
0.3
0
gpm
7.9
7
6
5
4
3
2
1
0
gpm
15.85
12
8
4
0
gpm
20.6
15
10
5
0
gpm
6.3
6
5
4
3
2
1
0
gpm
4.7
4
3
2
1
0
gpm
15.8
14
12
10
8
6
4
2
0
Δp=261psi
Δp= 18bar
Δp=261psi
Δp= 18bar
Δp=261psi
Δp= 18bar
Δp=261psi
Δp= 18bar
Δp=261psi
Δp= 18bar
Δp=261psi
Δp= 18bar
Δp=261psi
Δp= 18bar
Δp=261psi
Δp= 18bar
Δp=203psi
Δp= 14bar
Δp=203psi
Δp= 14bar
Δp=203psi
Δp= 14bar
Δp=203psi
Δp= 14bar
Δp=203psi
Δp= 14bar
Δp=203psi
Δp= 14bar
Δp=203psi
Δp= 14bar
Δp=203psi
Δp= 14bar
0 20 40 60 80 100%A
l/min
12
10
8
6
4
2
0
gpm
3.2
2.5
2.0
1.5
1.0
0.5
0
Flow Q
Flow QFlow Q
Flow Q
Flow Q
Flow Q
Flow Q
% of maximum control current
% of maximum control current
% of maximum control current % of maximum control current
% of maximum control current % of maximum control current
% of maximum control current
Nominal Flow = 1
Flow Q
% of maximum control current
Nominal Flow = 0
Nominal Flow = 4
Nominal Flow = 9 Nominal Flow = Z
Nominal Flow = 3
Nominal Flow = 2
Nominal Flow = 8
The curves refer to the spool fully open.
Measured with hydraulic fl uid ISO-VG32 at 45° ±5 °C
(113° ±9 °F); ambient temperature 20 °C (68 °F).
RE 18301-15/06.2018, Bosch Rexroth AG
4/3 and 4/2 Proportional directional valve elements | L8581… (EDC-P1)
Characteristic curves
7
The curves refer to the spool fully open.
Measured with hydraulic fl uid ISO-VG32 at 45° ±5 °C
(113° ±9 °F); ambient temperature 20 °C (68 °F).
0 10 20 30 40 50 60 l/min
0 10 15 20 25 30 bar
0 50 100 150 200 250 bar
0 10 20 30 40 50 60 l/min
bar
3
2.5
2
1.5
1
0.5
0
l/min
80
70
60
50
40
30
20
10
0
l/min
4
3
2
1
0
bar
30
25
20
15
10
5
0
psi
43.5
40
35
30
25
20
15
10
5
0
gpm
21,13
20
16
12
8
4
0
gpm
1,05
1,0
0,8
0,6
0,4
0,2
0
psi
435
400
350
300
250
200
150
100
50
0
P>A or P>B
B>T or A>T
0 2 4 6 8 10 12 14 15.8 gpm
0 200 400 600 800 870.2 psi
0 500 1500 2500 3625 psi
0 2 4 6 8 10 12 14 15.8 gpm
Pressure differential across the spool (ΔPls)
Pressure drop ∆p = ∆p(Q) (P
IN
- P
OUT
) to the next section
Nominal fl ow Qnom=Qnom (∆P ls) LS drain
Pressure Δp Flow Q
Flow Q
Pressure Δp
Pressure drop ∆p = ∆p(Q) with spool B2S9
5 section
4 section
3 section
2 section
1 section
Nominal fl ow = Z
Nominal fl ow = 9
Nominal fl ow = 8
Nominal fl ow = 4
Nominal fl ow = 3
Nominal fl ow = 2
Nominal fl ow = 1
Nominal fl ow = 0
Flow Q
Pressure Δp
Pressure p
Flow Q
Bosch Rexroth AG, RE 18301-15/06.2018
8 L8581… (EDC-P1) | 4/3 and 4/2 Proportional directional valve elements
External dimensions and fi ttings
Dimensions [mm (inches)]
External dimensions and fi ttings
()
()
()
()
()
()
()
()
()
()()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
1 Solenoid tube Ø 23 mm (0.91 inch).
2 Plug for 2 positions versions (4/2).
3 Ring nut for coil locking (Ø 30.3 mm).
Torque 6 – 7 Nm (4.4 – 5.2 ft-lb).
4 Flange specifi cations for coupling to ED intermediate elements.
5 For tie rod and tightening torque information see data sheet RE
18301-90.
6 Clearance needed for connector removal.
7 A and B ports.
8 Identifi cation label.
9 Optional push-button manual override, 0P type, for spool opening:
it is pressure stuck to the ring nut for coil locking.
Mat no. R933003424.
10 Optional screw type manual override, 0F type, for spool opening:
it is screwed (torque 6-7 Nm (4.4-5.2 ft-lb)) to the tube as
replacement of the coil ring nut. Mat no. R930056486.
11 Optional push-button manual override NP (black) and RP (red)
type, for spool opening. It is screwed (torque 6-7Nm(4.4-5.2 ft-
lb)) to the tube as replacement of the coil ring nut. Mat no.
R930056488(black) - R930056489 (red).
12 Optional twist type manual override, 0T type, for spool opening
and locking in the energised position. It is screwed (torque 6-7Nm
(44-5.2 ft-lb)) to the tube as replacement of the coil ring nut. Mat
no. R930056487
13 Four threaded holes M5 deepth 12mm (0.47 inch) for fi tting a
secondary fl angeable element. Bolts M5 with recommended
strength class DIN8.8: torque 5-6 Nm (3.6-4.4 ft-lb) (only for
version with modular secondary valves).
RE 18301-15/06.2018, Bosch Rexroth AG
4/3 and 4/2 Proportional directional valve elements | L8581… (EDC-P1)
External dimensions and fi ttings
9
Dimensions [mm (inches)]
()
()
()
()
()
()
()
()()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
1 Ordering Details: HA (if fi tted to side A) or HB (if fi tted to side B)
2 Ordering Details: VA (if fi tted to side A) or VB (if fi tted to side B)
3 Ordering Details: H1 (if fi tted to side A) or H9 (if fi tted to side B)
4 Ordering Details: V1 (if fi tted to side A) or V9 (if fi tted to side B)
5 Ordering Details: XA (if fi tted to side A) or XB (if fi tted to side B)
6 Ordering Details: X1 (if fi tted to side A) or X9 (if fi tted to side B)
Bosch Rexroth AG, RE 18301-15/06.2018
10 L8581… (EDC-P1) | 4/3 and 4/2 Proportional directional valve elements
External dimensions and fi ttings
Dimensions [mm (inches)]
External dimensions for spool with nominal fl ow 9 and Z
()
() ()
()
()
()
1 Flow-boost system only for spool with nominal fl ow 9 and Z.
It always mounted on "b" side of the valve.
RE 18301-15/06.2018, Bosch Rexroth AG
4/3 and 4/2 Proportional directional valve elements | L8581… (EDC-P1)
External dimensions and fi ttings
11
Dimensions [mm (inches)]
External dimensions for spool with nominal fl ow 9 and Z
()
()
()
1 Flow-boost system only for spool with nominal fl ow 9 and Z.
It always mounted on the opposite side of the lever manual
override.
12
Bosch Rexroth AG, RE 18301-15/06.2018
Bosch Rexroth Oil Control S.p.A.
Oleodinamica LC Division
Via Artigianale Sedrio, 12
42030 Vezzano sul Crostolo
Reggio Emilia - Italy
Tel. +39 0522 601 801
Fax +39 0522 606 226 / 601 802
compact-hydraulics-cdv@boschrexroth.com
www.boschrexroth.com/compacthydraulics
© This document, as well as the data, specifi cations and other information
set forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a..
It may not be reproduced or given to third parties without its consent.
The data specifi ed above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The information given does not release the
user from the obligation of own judgment and verifi cation. It must be
remembered that our products are subject to a natural process of wear and
aging.
Subject to change.
L8581… (EDC-P1) | 4/3 and 4/2 Proportional directional valve elements
Electric connection
Dimensions [mm (inches)]
Electric connection
01
Protection class: IP 65 when connector with seal is properly
screwed down.
03
Protection class: IP 65 with female connector
properly fi tted (see drawing).
()
()
()
()
()
()
()
()
()
()()
()
()
()
07
Protection class: IP 69 K with female connector
properly fi tted.
()
() ()
()
()
()
()