RE 18300-13/02.2016, Bosch Rexroth AG
Inlet Elements
with by-pass compensator, LS relief for open center
control block and solenoid operated unloading
RE 18300-13
Edition: 02.2016
Replaces: 07.2012TE-13-__-
Description
The inlet elementsTE-13-__ are employed to connect the
external P, T lines to the P, T channels inside the ED
elements of the Directional Valve Assembly and to connect
the LS line for inlet fl ow control. An LS controlled 3-way
compensator provides pressure compensated fl ow to the
ED elements of the Directional Valve Assembly, any excess
ow si bypassed to tank at LS pressure plus compensator
spring bias. When the ED elements are in neutral position,
the compensator bypasses the entire fl ow to tank at a
bypass pressure equal to the compensator spring bias. In
case the LS pressure reaches the relief pressure setting,the
compensator unloads to tank the entire fl ow at relief
pressure plus compensator spring bias The TE-13 can be
equipped with a NO or NC Solenoid Unloading VEI
Cartridge, which can be employed to unloads to tank the LS
signal and bypasses the entire fl ow to tank at a bypass
pressure equal to the compensator spring bias. The TE-13
is provided with non compensated bleed down orifi ce. The
TE-13-…. is made of zinc plated cast iron. The coil S8-356
must be ordered separately (refer to RE18325-90).
Technical data
General
TE13 kg (lbs) 3.6 (7.9)
Ambient Temperature °C (°F) –20....+50 (-4....+122)
(NBR seals)
Hydraulic
Maximum pressure bar (psi) 310 (4500)
Maximum inlet fl ow for
TE-13-_ _-3 version
l/min (gpm) 33 (8.7)
Maximum inlet fl ow for
TE-13-_ _-5 version
l/min (gpm) 50 (13.2)
Maximum inlet fl ow for
TE-13-_ _-8 version
l/min (gpm) 80 (21.1)
Maximum inlet fl ow for
TE-13-_ _-0 version
l/min (gpm) 120 (31.7)
Rated fl ow at P1 l/min (gpm) Variable
1)
Hydraulic fl uid
General properties: it must have
physical lubricating and chemical
properties suitable for use in
hydraulic systems such as, for
example:
Mineral oil based hydraulic
uids HL (DIN 51524 part 1).
Mineral oil based hydraulic
uids HLP (DIN 51524 part 2).
For use of environmentally
acceptable fl uids
(vegetable or polyglycol
base) please consult us.
Fluid Temperature °C (°F) –20....+80 (-4....+176) (NBR)
Permissible degree of
uid contamination
ISO 4572: β
x
≥75 X=10...12
ISO 4406: class 19/17/14
NAS 1638: class 8
Viscosity range mm
2
/s 5....420
1) The maximum regulated fl ow on P1 line is related both to the
pressure drop of the ED valve assembled on the group and their
spools size.
Note
For applications with different specifi cations consult us
Bosch Rexroth AG., RE 18300-13/02.2016
2 TE-13-__- | Inlet Elements
Ordering details
Ordering details
01 02 03 04 05 06 07 08 09 10
TE-13--------CI
Family
01 Inlet Elements
TE
Confi guration
02 Function with fi xed displacement pump (open centre)
13
Ports
03 G 1/2 DIN 3852
03
G 3/4 DIN 3852
04
7/8-14 UNF-2B (SAE10)
57
Spool dimension
04 Maximum inlet fl ow 33 l/min (8.7 gpm)
3
Maximum inlet fl ow 50 l/min (13.2 gpm)
5
Maximum inlet fl ow 80 l/min (21.1 gpm)
8
Maximum inlet fl ow 120 l/min (31.7 gpm)
0
Pressure Relief range
05 25-120bar (350-1750 psi)
1
40-200bar (580-2900 psi)
2
200-310bar (2900-4500 psi)
3
Compensator Cracking Pressure
06 14 bar (203 psi)
1)
14
18 bar (261 psi)
18
Adjustable 8-18 bar (116-261 psi)
Standard setting 10 bar (145psi)
R8
Adjustable 10-18 bar (116-261 psi) with locking option
Standard setting 12 bar (174 psi)
2)
BR
LS bleed down orifi ce
07 Diam. 0.3 (Ø0.5+wire0.4)
1)
C
Diameter 0.4
E
Diameter 0.5
G
Unloading Valve
08 Without valve (ordered separately)
0
Standard VEI normally open
A
Standard VEI normally closed
C
Plugged
P
Pilot Restrictor
09 Standard
0I
STR14CI
3)
CI
Material
10 Cast Iron
CI
1) Recommended version.
2) Suggested for open/closed center confi guration.
3) STR14CI not available for TE-13 with SAE 10 ports.
Symbol
Without unloading valve and fi xed pilot restrictor
T1
TP LS
P1
With unloading valve and STR pilot restrictor
T1
TLSP
P1
RE 18300-13/02.2016, Bosch Rexroth AG
Inlet Elements | TE-13-__-
Characteristic curves
3
Characteristic curves
Model Curve no.
TE-13-_ _-3_- 14 Version 1
TE-13-_ _-5_- 14 Version 2
TE-13-_ _-8_- 14 Version 3
TE-13-_ _-0_- 14 Version 4
Model Curve no.
TE-13-_ _-3_- 18/R8 Version 5
TE-13-_ _-5_- 18/R8 Version 6
TE-13-_ _-8_- 18/R8 Version 7
TE-13-_ _-0_- 18/R8 Version 8
TE-13-_ _-0_- R8 lowest adjustable setting 9
Fixed orefi ce Curve no.
Ø0.5mm 1
Ø0.4mm 2
Ø0.3mm 3
1 2 3 4
0 20 40 60 80 100 120 l/min
0 5 10 15 20 25 30 31.7 gpm
bar
20
15
10
5
0
psi
280
210
140
70
0
Pressure Δp
Flow Q
Pressure drop trough compensator
Flow rate compensation (P1)
LS drain
5 6 7 8 9
0 20 40 60 80 100 120 l/min
0 5 10 15 20 25 30 31.7 gpm
bar
20
15
10
5
0
psi
280
210
140
70
0
Pressure Δp
Flow Q
l/min
80
60
40
20
0
0 50 100 150 200 250 bar
0 500 1500 2500 3625 psi
gpm
21.1
20
16
12
8
4
0
Flow Q
Pressure-P1
3 2 1
l/min
4
3
2
1
0
0 50 100 150 200 250 bar
0 500 1500 2500 3625 psi
gpm
1.05
1.0
0.8
0.6
0.4
0.2
0
Flow Q
Pressure-p
Measured with hydraulic fl uid ISO-VG32 at 45° ±5 °C
(113° ±9 °F); ambient temperature 20 °C (68 °F).
4
Bosch Rexroth AG, RE 18300-13/02.2016
Dimensions [mm (inches)]
Bosch Rexroth Oil Control S.p.A.
Oleodinamica LC Division
Via Artigianale Sedrio, 12
42030 Vezzano sul Crostolo
Reggio Emilia - Italy
Tel. +39 0522 601 801
Fax +39 0522 606 226 / 601 802
compact-hydraulics-cdv@boschrexroth.com
www.boschrexroth.com/compacthydraulics
© This document, as well as the data, specifi cations and other information
set forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a..
It may not be reproduced or given to third parties without its consent.
The data specifi ed above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The information given does not release the
user from the obligation of own judgment and verifi cation. It must be
remembered that our products are subject to a natural process of wear and
aging.
Subject to change.
External dimensions and fi ttings
()
()
()
()
()
() ()
()
() ()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()()
()
()
()
()
()()
() ()
()
()
1 Flange specifi cations for coupling to the ED Directional Valve
Elements.
2 For tie rod and tightening torque information see data sheet
RE 18301-90.
3 Hydraulic ports P and T G1/2, inlet elements TE-13-03-...
4 Hydraulic ports P and T G3/4, inlet elements TE-13-04-...
5 Test point LS port G1/4, inlet elements TE-13-03-..and TE-13-04.
6 Hydraulic ports P and T SAE10, inlet element TE-13-57-...
7 Test point LS port SAE6, inlet element TE-13-57-...
8 Pressure relief cartridge VMD1020, with screw type adjuster.
9 Unloading valve CA-08A-2N cavity plug TE-13-..-..-..-.P-.
10 Solenoid Unloading cartridge VEI-8A-2T-06... type.
11 VEI Coil S8-356 ordered separately.
12 Both adjustable cracking pressure version (R8) and locking option (BR).
13 Maximum torque of the nut 5-6 Nm (R8 and BR).
14 Maximum torque of the locking screw (BR) 9-10 Nm.
Dimensions [mm (inches)]
TE-13-__- | Inlet Elements
External dimensions and fi ttings