4/10 Bosch Rexroth AG Hydraulics
Technical data (For applications outside these parameters, please consult us!)
hydraulic
Maximum operating pressure – Version "U" bar 500 (at all ports if P ≥ A; for design reasons)
– Version "R" bar 350 (at all ports)
Maximum flow – Version "U" l/min 3 (see limits of performance page 6)
– Version "R" l/min 5 (see limits of performance page 6)
Hydraulic fluid See table below
Hydraulic fluid temperature range °C –40 to +80
Viscosity range mm
2
/s 4 to 500
Maximum permitted degree of contamination of the hydraulic
fluid - cleanliness class according to ISO 4406 (c)
Class 20/18/15
1)
Load cycles – Version "R" (350 bar) 10 million
– Version "U" (500 bar) 5 million
general
Weight – Valve kg 0.30
– Coil kg 0.25
Installation position Any
Ambient temperature range °C –40 to +110
1)
The cleanliness classes specified for the components must
be adhered to in hydraulic systems. Effective filtration pre-
vents faults and at the same time increases the service life
of the components.
For the selection of the filters see www.boschrexroth.com/filter.
Hydraulic fluid Classification
Suitable sealing materials
Standards
Mineral oils and related hydrocarbons HL, HLP, HLPD, HVLP, HVLPD FKM DIN 51524
Environmentally compatible
– Insoluble in water
HETG FKM
ISO 15380
HEES FKM
– Soluble in water HEPG FKM ISO 15380
Flame-resistant
– Water-free HFDU, HFDR FKM ISO 12922
– Water-containing HFAS FKM ISO 12922
Important information on hydraulic fluids!
– For more information and data on the use of other hydrau-
lic fluids refer to data sheet 90220 or contact us!
– There may be limitations regarding the technical valve
data (temperature, pressure range, service life, mainte-
nance intervals, etc.)!
– The flash point of the process and operating medium used
must be 40 K higher than the maximum solenoid sur-
face temperature.
– Flame-resistant – water-containing: Maximum pressure
differential per control edge 175 bar, otherwise, increased
cavitation erosion!
Tank pre-loading < 1 bar or > 20 % of the pressure
differential. The pressure peaks should not exceed the
maximum operating pressures!
– Environmentally compatible: When using environmen-
tally compatible hydraulic fluids that are simultaneously
zinc-solving, zinc may accumulate in the medium (700 mg