2
RA 95 546/01.93
Technical data (partly to VDI 3276)
Design: direct operated, seated type pressure relief valve
Mounting:
flange model with O-ring seals or threaded connections
Pipe connections and connection sizes:
see unit dimensions
Weight lbs (kg) Series 5
without subplate 10 (4.5) 5 (2.3)
with subplate 14.3 (6.5) 8.8 (4.0)
Mounting position: optional
Direction of flow: from P
St
to R
Operating pressure range
High pressure side: p
HD
= 0 ... 5800 PSI (0 ... 400 bar)
Pilot pressure side: p
St
= 0 ... 870 PSI (0 ... 60 bar)
Pressure setting range (pilot pressure side)
p
St
= 145 ... 406 or 145 ... 652 PSI (10 ... 28 or 10 ... 45 bar)
(alternative settings on request)
The pressure setting range must be stated in clear text when
ordering.
Fluid temperature range
δ
m min
... δ
m max
= – 4 ... 176 °F (– 20 ... + 80 °C)
Viscosity range
ν
min
...ν
max
= 45 ... 4640 SUS (10 ... 1000 mm
2
/s)
Nominal flow Q
N
= 1.3 GPM (5 L/min)
Pilot pressure curve
Q
N
= 1.3 GPM (5 L/min)
ν = 767 SUS (35 mm
2
/s)
δ = 122 °F (50 °C)
10
0 0.25
(1)
(1) (10)
(2)
(3)
(4)
20
30
40
50
55
(2) (3) (4) (5) (6) (7) (8) (9)
0.5 0.75 1.0 1.25 1.5 1.75 2.0 2.25 2.5
Differential pressure ∆p PSI (bar)
Flow Q GPM (L/min)
∆p-Q-curve
Power curves
The power curves follow extensively the power curves laid down
in DIN 42 973, and the rated powers of axial piston units with built
on regulating devices.
For the various power curves available, according to unit see and
size, see pages 3 to 5.
Power overshoot
The variation in regulated value of a power limiting valve is very
small, as the response time is 0.02 sec. When used with con
device S 3041, or the HD control, the actual variation is great as
the minimum setting time of the pump is limited to 0.15 sec. or 0.2
sec. respectively.
For further details of control tolerances, see catalogue sheet
“Control Elements model S”, series E and C.
ν = 767 SUS (35 mm
2
/s)
δ = 122 °F (50 °C)
Co-ordination with control devices
Direct mounting
Direct mounting on the HD control (series 5) (note point 5 in
ordering code).
Note that control type S 3041 is changed when LV 06 is fitted S
3141.
Separate mounting
Power limiting valve LV 06 can be fitted in the pilot circuit of axial
piston units with pressure dependent control devices independent
of the build series, if it is installed separately.
Application example
Port P
St
is connected via a shuttle valve with the pilot circuit of
control device, while port P
HD
is connected via another shuttle
valve into the main circuit of the axial piston pump. If the
operating pressure ex-
ceeds the pre-load of the
regulating spring for the
start of control, the
stepped piston moves
against the spring set and
so reduces the load on
the pilot control spring
and, in turn, the pilot
pressure, so that the
predetermined maximum
drive power at a constant
drive speed is never ex-
ceeded at any operating
point.
Operating curves
100
0
(10)
(50)
20 40 60 80 100
(20)
(30)
(40)
(28)
(45)
200
300
400
500
600
700
Differential pressure ∆p PSI (bar)
Adjustment stroke s (%)