Contents
1 Preface .....................................................................2
2 Ordering code ..........................................................3
3 Functional description .............................................4
4 Technical data .......................................................11
5 Pressure loss diagram ...........................................12
6 Required charge pressure diagram ........................14
7 Dimensions / Interface ........................................... 15
8 Safety and installation instruction .........................18
9 Required and additional documents ......................23
RE 15389/02.2018, Bosch Rexroth AB
2-speed valve
Hägglunds VTCA 600
Includes valves for ATEX environment
Features
Displacement shift for Hägglunds CA motor
Compact and robust design
Multifunctional
Can be mounted directly on Hägglunds motors
Built in brake control function
Exchange of oil in motor case
Possibility for internal control pressure.
Valid for: Hägglunds motors CA
Maximum ow 600 l/min (158 gpm)
For closed and open loop hydraulic system
RE 15389
Edition: 02.2018
Replace: New
2/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
1 Preface
Warning signs
In this manual you will find the following signs which
indicate a potential hazard, which can or will cause
personal injury or substantial property damage. Depending
on the probability if the hazard, and how serious the injury
or property damage could be, there are three levels if
classification.
Warning sign (warning
triangle):
Draws attention to the hazard
Signal word: Identifies the degree of hazard
Type of risk:
Specifies the type or source of
the hazard
Consequences:
Describes the consequences of
non-compliance
Precautions:
Specifies how the hazard can be
prevented
The signal words have the following meaning:
Warning sign, signal word Meaning
DANGER
Indicates a dangerous situation
which will cause death or severe
personal injuries if not avoided.
WARNING
Indicates a dangerous situation
which may cause death or severe
personal injuries if not avoided.
CAUTION
Indicates a dangerous situation
which may cause minor or medium
personal injuries if not avoided.
NOTICE
Material damage: the product or its
environment could be damaged.
WARNING
Load drop
Danger to life or risk of injury, damage to equipment!
Charge pressure at the motors connection, must be
according to graph (see 6 Required charge pressure
diagram page 14) under all conditions
Valve version VTCA 600 X X X X XX 05, mirror inverted,
is not allowed to be used in suspended load application
Hägglunds VTCA 600 | 2-speed valve 3/24
RE 15389/02.2018, Bosch Rexroth AB
2 Ordering code
In order to identify Hägglunds equipment exactly, the following ordering code is used. These ordering codes should be
stated in full in all correspondence e.g. when ordering spare parts. Example: Valve VTCA 600:
VT C A 600 0 H 1 0 0 00
01 02 03 04 05 06 07 08 09 10
01 2-speed valve
VT
02 For motors
CA 50 to CA 210
5)
C
03 Version
A
04 Maximal ow (l/min)
600 600
05 Brake function
Without brake function 0
With brake function
3)
B
06 Operation
Electrical operated 24VDC
4)
E
Hydraulic operated H
07 Exchange of oil in motor casing
Not prepared 0
Prepared 1
08 Explosive environment
Non explosive environment 0
Explosive environment
2)
1
09 Modication
1)
0-9
10 Design
Standard 00
Mirror inverted
6) 7)
05
Special index
1)
01-99
1) To be lled in by Bosch Rexroth DC-HD/ENG
2) Only valid for attribute 05 code 0 and attribute 06 code H
3) Only in combination with electric operated valve
4) Other than 24VDC, must be ordered separatly
5) Only valid for two speed motors (R/L)
6) In combination with Special index motor 06
7) Not allowed to be used in suspended load applications
4/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
3 Functional description
3.1 General
Hägglunds Compact CA 50-210 motors in 2-speed
configuration in combination with VTCA 600 valve can shift
displacement from full to half displacement while running
up to 30 rpm and high pressure maximum 105 bar.
Displacement shift from half to full displacement is not
allowed while the motor is rotating.
Shifting from full to half displacement means that 25% of
the pistons are provided with high pressure and 75% of the
pistons are provided with low pressure. This resulting in
twice the speed and half the output torque compared to
full displacement. The valve can be mounted directly onto
the motor and can be used in both open and closed loop
systems.
When ordering a motor prepared for 2-speed function the
main rotation, clockwise (R) or counter clockwise (L), has
to be specified. With wrong direction, load on the piston
will be increased 3 times, which can give overheating of the
pistons.
With the flow inlet connected to P (A-port on motor), the
motor shaft rotates in the directions shown by arrows. (see
Fig. 1 and Fig. 2) R-motor rotates clockwise, and L-motor
counter-clockwise, viewed from the motor shaft side. If the
motor is working in half displacement, and in reversed
”direction of rotation”, is the allowed pressure max 210 bar
(3000 psi).
For higher speed, two valves can be used, one standard
valve and one S-index 05 valve (mirrored inverted).
Maximum operating pressure is 350 bar (5076 psi) and
maximum flow 600 l/min (158 gpm). When using a 2-speed
motor, check the system temperature due to higher
pressure loss, flushing may be necessary and 2-speed
applications for motors with reduced displacements are not
recommended.
The valve is available in five main configurations:
VTCA 600 0 H: Hydraulic operated displacement
shift.
VTCA 600 0 H S-index 05: Hydraulic operated
displacement shift. Two valves.
VTCA 600 0 E: Electric operated displacement shift,
24 VDC.
VTCA 600 E S-index 05: Electric operated
displacement shift, 24 VDC. Two valves.
VTCA 600 B E: Electric operated displacement shift
with brake control function, 24 VDC.
Fig. 1: Motor prepared for valve, direction of rotation, Counter-
clockwise = L
Fig. 2: Motor prepared for valve, direction of rotation, Clockwise = R
C
P
P
C
(A-port on motor)
(A-port on motor)
Hägglunds VTCA 600 | 2-speed valve 5/24
RE 15389/02.2018, Bosch Rexroth AB
3.2 Function
3.2.1 Valve VTCA 600 0 H 0 and VTCA 600 0 H 1
Hydraulic operated valve.
The displacement shift function is controlled by a
directional valve (2), see Fig. 6, which is kept in the full
displacement position by spring action. The control
pressure for the directional valve is obtained from an
external source through port “Pc“.
3.2.2 Valve VTCA 600 0 E 0 and VTCA 600 0 E 1
Electrical operated valve
The displacement shift function is controlled by a
directional valve (2), see Fig. 7, which is kept in the full
displacement position by spring action. The control
pressure for the directional valve is controlled by an
electrical operated directional valve (3) see Fig. 7. The
control pressure is obtained from an external source
through port “Pc“ or internally from “P“.
Using internal control pressure from “P“
(Only VTCA 600 0 E)
The VTCA 600 valves are at delivery prepared for control
pressure connection at “Pc“. In case of electric operated
valve (VTCA 600 0 E), the control pressure can be obtained
internally from “P“ by following instructions below and Fig. 3.
1. Remove plug (B).
2. Remove plug (010).
3. Mount plug (B), tightening torque: 10 Nm.
4. Install a plug at connection
Pc
, G 1/2“, material ID
R913001725
A-A
B
B
Pc
P
B
A
A
010
010
010
Fig. 3: Using internal control pressure from “P“ (Only VTCA 600 0 E)
6/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
3.2.3 Exchange of oil in motor casing
VTCA 600 0 H 1, VTCA 600 0 E 1 and VTCA 600 B E 1
are prepared for exchange of oil in motor casing. Nominal
oil exchange, with an orifice with a Ø 2 mm hole, is 12 l/
min (3.1 US gal/min) at a pressure in “C“-line of 25 bar
(365 psi).
3.2.4 Valve VTCA 600 B E 0 and VTCA 600 B E 1
Electric operated with brake function.
(See Fig. 8 and Fig. 9)
The displacement shift function is controlled by a
directional valve (2) which is kept in the full displacement
position by spring action. The control pressure for the
directional valve is controlled by an electrical operated
directional valve (3), ISO 4401, included in delivery. The
control pressure is obtained from an external source
through port “Pc“.
Brake function
The brake function is electrical operated. The control
pressure for the brake is controlled by two electrical
operated directional valves (3 and 6), and the brake is
connected to connection “BR“. The control pressure is
obtained from an external source through port “Pc“.
Brake o
When the electrical operated directional valves are open,
the pressure from “Pc“ shifts the directional valve (4),
check valve (5) is closed and the pressure are guided to
“BR“ and the brake release.
Brake on
When the electrical operated directional valve (3) is closed,
the directional valve (4) shifts and the check valve (5)
opens. Spring pressure in the brake cylinder pushes then
oil to tank and the brake applies.
The VTCA 600 0 H 0 and VTCA 600 0 E 0 valves are, at
delivery not prepared for exchange of oil in motor case.
Port (8 )is plugged, and port (9 )is not plugged.
See also hydraulic circuits Fig. 6. and Fig. 7
The valve can be prepared for exchange of oil in motor case
by following instructions and Fig. 5.
NOTICE
High internal pressure in motor case
Risk of damage motor.
Make sure that an external draining line is connected to
one of the external drain connections D1, D2 or D3 on
the motor.
1. Replace the plug (008), M8, with an orifice, material ID
R939055162
2. Install plug (009), R3/8˝, material ID R913053036.
3. Lock the plugs with Loctite 577 or similar.
Hägglunds VTCA 600 | 2-speed valve 7/24
RE 15389/02.2018, Bosch Rexroth AB
Fig. 4: Exchange of oil in motor case vs pressure in C-line
Fig. 5: Exchange of oil in motor case for VTCA 600 0 H 0 and VTCA 600 0 E 0
DD00090971
DD00090978
8/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
Fig. 6: Hydraulic Circuit for VTCA 600 0 H 0, VTCA 600 0 H 0 S-index 05, VTCA 600 0 H 1 0 and VTCA 600 0 H 1 0 S-index 05
DD00090979
Hägglunds VTCA 600 | 2-speed valve 9/24
RE 15389/02.2018, Bosch Rexroth AB
Fig. 7: Hydraulic Circuit for VTCA 600 0 E 0 ,VTCA 600 0 E 0 S-index 05, VTCA 600 0 E 1 and VTCA 600 0 E 1 S-index 05 .
DD00090980
10/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
Fig. 8: Hydraulic circuit for VTCA 600 B E 0
Fig. 9: Hydraulic circuit for VTCA 600 B E 1
DD00090983
DD00090985
Hägglunds VTCA 600 | 2-speed valve 11/24
RE 15389/02.2018, Bosch Rexroth AB
4 Technical data
4.1 General data
Metric US
Mechanical specication
Maximum operating pressure 350 bar 5 076 psi
Maximum operating pressure reversed direction 210 bar 3 000 psi
Pilot pressure 7 min. to 350 max. bar 101 min. to 5 076 max. psi
Maximum Flow (see 5 Pressure loss diagram page 12) 600 l/min 158 gpm
Hydraulic Fluid (refer to Data sheet RE 15414 Hydraulic uid quick reference )
Maximum Fluid Temperature +70°C +158°F
Minimum Fluid Temperature -25°C -13°F
Maximum Viscosity Range 380 cSt 1760 SSU
Minimum Viscosity Range 20 cSt 98 SSU
Recommended Operating Viscosity 40 cSt 187 SSU
Weight
2-speed valve typical VTCA 600 0 H 29 kg 63 lb
2-speed valve typical VTCA 600 0 E 29.3 kg 64 lb
2-speed valve typical VTCA 600 B E 36 kg 79 lb
Pilot valve: Connectors EN 175301-803 / Sea water protected
Supply voltage 24 VDC
Solenoid power 12 W
Solenoid current 0.5 A
Solenoid protection class (EN 175301-803) IP65
Surface protection
Standard painting system SS-EN ISO 12944 C3, durability range M (Std, colour RAL 2002)
Area of application according to ATEX directive 2014/34/EU IM2, II2G, II2D, II3G, II3D
Protection of the valve by liquid immersion according to and
constructional safety according to
k (EN 13463-8)
c (EN 13463-5)
Maximum surface temperature + 100 ºC (+212 ºF)
Temperature class T4
Conforms to “Equipment and components intended for use in
potentially explosive atmospheres and in underground mines”
EN 1710
ATEX Classication of valve II 2 G D c k T4 / I M2 c k T4
Ambient temperature range -25…..+50 ºC (-13....+122 ºF)
4.2 Explosion protection information, hydraulic operated VTCA 600
Table 1: Explosion protection information hydraulic VTCA 600
Table 2: General data VTCA 600
12/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
5 Pressure loss diagram
Fig. 10: Pressure loss main circuit P - C at full displacement for standard valve (motor and valve included) Viscosity 40 cSt/187 SSU.
Fig. 11: Pressure loss main circuit P-C at half displacement for standard valve (motor and valve included) Viscosity 40 cSt/187 SSU
DD00090988
DD00090990
Hägglunds VTCA 600 | 2-speed valve 13/24
RE 15389/02.2018, Bosch Rexroth AB
Fig. 12: Pressure loss main circuit P - C at full displacement for standard valve + S-index 05 valve (motor and valve included)
Viscosity 40 cSt/187 SSU.
Fig. 13: Pressure loss main circuit P-C at half displacement for standard valve + S-index 05 valve (motor and valve included)
Viscosity 40 cSt/187 SSU
DD00090994
DD00090995
14/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
6 Required charge pressure diagram
Fig. 14: Required charge pressure when running in half displacement for standard valve (Motor and valve included)
Fig. 15: Required charge pressure when running in half displacement for standard valve + S-index 05 valve (Motor and valves included)
DD00090999
DD00091000
Hägglunds VTCA 600 | 2-speed valve 15/24
RE 15389/02.2018, Bosch Rexroth AB
7 Dimensions / Interface
Fig. 16: Dimensions VTCA 600 0 H 0 0 0 00, VTCA 600 0 H 0 1 0 00
Fig. 17: Dimensions VTCA 600 0 E 0 0 0 00
DD00091001
DD00091002
16/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
Fig. 18: Dimensions VTCA 600 0 H 0 0 0 05, VTCA 600 0 H 0 1 0 05
Fig. 19: Dimensions VTCA 600 B E 0 0 0 00
DD00076298
DD00091013
Hägglunds VTCA 600 | 2-speed valve 17/24
RE 15389/02.2018, Bosch Rexroth AB
Fig. 20: Dimensions VTCA 600 0 E 0 0 0 05
DD00091015
18/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
Fig. 21: Dimensions VFWCB 600 H, special index 03
WARNING
Escaping oil mist!
Risk of explosion, re health hazard, environmental
pollution.
Depressurize the system including valve and repair the
leak.
Keep open ames an ignition sources from the
Hägglunds valve
Static discharge
Cleaning the valve with a dry rug may lead to explosions
through electrostatic dis-charge that may cause severe
injuries and even death
Do not use a dry rug for cleaning
Lack of grounding
Risk of explosion that may cause severe injuries and even
death
The valve must always be tted to the motor or via
adapter tted to the motor. The valve must be electrical
conductive and equipotential bonded with the motor
which must be grounded to the system.
The valve are not allowed to be tted to any separate
bracket without grounding of the valve.
Painting
Risk of explosion that may cause severe injuries and even
death
The valve must not be painted or otherwise coated
with non-conductive sub-stances!
Any change at the surface protection will lead to loss of
explosion protection!
DANGER
Unsafe work on the valve
Danger to life or risk of injury, damage to equipment!
Before carrying any work on the valve, rstly make sure
that a potentially explosive atmosphere cannot occur
during the period of the work
8 Safety and installation instruction
8.1 Safety instructions
8.1.1 General safety instructions
DANGER
Danger from excessively high pressure!
Danger to life or risk of injury, damage to equipment!
Using the valve above the permissible maximum pressure
can cause valve burst and hydraulic uid to escape under
high pressure.
Use the valve within the permissible maximum pressure
Pressurized valve
Danger to life risk of injuries when working on valve in
system not being depressurized
Protect the system against being energized.
Make sure that the system is depressurized.
Do not disconnect any line connection, ports and
components when the system is pressurized
8.1.2 Safety instructions for ATEX environment
Hägglunds VTCA 600 | 2-speed valve 19/24
RE 15389/02.2018, Bosch Rexroth AB
8.2 Installation
8.2.1 Fitting the VTCA 600 valve on Hägglunds CA
Refer also to the Installation and Maintenance Manual RE
15302-WA.
NOTICE
Contamination of the system!
Risk of damage components.
Clean all mounting surfaces before assembly!.
Remove the SAE flanges from motor mounting
surface and the plastic plugs from the valve
mounting surface.
Place the O-rings (included in delivery) in their
proper position on the valve mounting surface.
Use clean grease to keep O-rings fixed during
assembly.
Mount the valve against the motor with the ports in
the correct position.
Re-instate paint finish and protect exposed surfaces
Pos Description
1
4 pcs 1/2 UNC x 127 (5“) (included in delivery)
Tightening torque: 131 Nm (97 lbf·ft)
2
4 psc Washer 19/13.5 T=2 hardened HB 450-500 (included
in delivery)
3 Valve VTCA 600
4 2 pcs O-rings ø34,59x2,62 FPM 70 (included in delivery)
5 1 pcs O-ring 26,64x2,62 FPM 70 (included in delivery)
6 1 pcs O-ring 23,47X2,62 FPM70 (included in delivery)
Fig. 22: Hägglunds CA
1
3
4
DD00076304
Note!
S-index 05
must have the
sign in this
postition
1
3
6
5
4
6
5
2
2
20/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
Am
Am
P
P
P
2
P
2
Pc
Pc
C
C
D
D
C
2
C
2
Cm
Cm
B
2
B
2
Fig. 23: Installation drawing – VTCA 600 0 H, VTCA 600 0 H S-index 05
8.3 Installation drawing
8.3.1 VTCA 600 0 H, VTCA 600 0 H S-index 05
Refer to dimensional drawing: 278 2204, 041 0460
8.3.2 VTCA 600 0 E, VTCA 600 0 E S-index 05
Refer to dimensional drawing: 278 2205, 041 0459
Am
Am
P
P
P
2
P
2
Pc
Pc
C
C
D
D
C
2
C
2
Cm
Cm
B
2
B
2
Fig. 24: Installation drawing – VTCA 600 0 E, VTCA 600 0 E S-index 05
DD00076308
DD00076309
Hägglunds VTCA 600 | 2-speed valve 21/24
RE 15389/02.2018, Bosch Rexroth AB
Fig. 25: Installation drawing – VTCA 600 B E
8.4 Installation drawing
8.4.1 VTCA 600 B E
Refer to dimensional drawing: 278 2206
DD00091020
Connection Description Port Connection Remarks
P, C Main connection SAE 1 1/4 *
Pc Pilot pressure connection BSP 1/2"
D Drain connection BSP 3/4"
Am Pressure point connection BSP 1/4"
Cm Pressure point connection BSP 1/4"
BR Brake line connection BSP 3/4"
BRX Pressure point connection BSP 3/8"
Sa Pressure point connection BSP 1/4"
S Pressure point connection BSP 1/4"
P
2
Connection BSP 1 1/4" For two motors
B
2
Connection BSP 3/4" For two motors
C
2
Connection BSP 1" For two motors
* J518C, Code 62, 414 Bar (6000 psi)
22/24 2-speed valve | Hägglunds VTCA 600
Bosch Rexroth AB, RE 15389/02.2018
Fig. 26: Circuit diagram standard terminal box
8.5 Electrical installation
DD00090970
Hägglunds VTCA 600 | 2-speed valve 23/24
RE 15389/02.2018, Bosch Rexroth AB
Title Document no Document type
Hydraulic uid quick reference RE 15414 Data sheet
Hägglunds valve adapters
RE 15383 Data sheet
2-speed valve VTCA 600 0 H 278 2204*) Dimension drawing
2-speed valve VTCA 600 0 E 278 2205*) Dimension drawing
2-speed valve VTCA 600 0 B 278 2206*) Dimension drawing
2-speed valve VTCA 600 0 E S-index 05 041 0459*) Dimension drawing
2-speed valve VTCA 600 0 H S-index 05 041 0460*) Dimension drawing
Documents at Bosch Rexroth Media Directory
*) Documents only available at myRexroth. Contact your Bosch Rexroth representative for information.
9 Required and additional documents
Bosch Rexroth AB
895 80 Mellansel, Sweden
Tel: +46 (0) 660 870 00
Fax: +46 (0) 660 871 60
documentation.mll@boschrexroth.se
www.boschrexroth.com
The data specied above only serve to describe the product.
As our products are constantly being further developed, no statements con-
cering a certain condition or suitability for certain application can be derived
from our information. The information given does not release the user from
the obligation of own judgement and verication. It must be remembered
that our products are subject to a natural process of wear and aging.
Bosch Rexroth AB, RE 15389/02.2018
24/24 2-speed valvee | VTCA 600