Directional control valve | 4WRPFH 19/20
RE29395, edition: 2022-03, BoschRexrothAG
Accessories (separate order)
Mating connectors and cable sets
Port Designation Version Short
designation
Material
number
Data
sheet
XH1 Mating connector;
for valves with round connector,
6-pole+PE
Straight, metal 7PZ31...M R900223890 08006
Straight, plastic 7PZ31...K R900021267
Angled, plastic – R900217845 –
Cable sets;
for valves with round connector,
6-pole+PE
Plastic, 3.0m 7P Z31 BF6 R901420483 08006
Plastic, 5.0m R901420491
Plastic, 10.0m R901420496
Plastic, 20.0m – R901448068 –
X7E1,
X7E2
Cable set;
shielded, 4-pole,D coding
Straight connectorM12, on straight
connectorM12, line cross-section 0.25mm
2
,
CAT5e, length freely selectable (=xx.x)
– R911172111
1)
–
Cable set;
shielded, 4-pole
Straight connectorM12, on straight connector
RJ45, line cross-section 0.25mm
2
, CAT5e,
length freely selectable (=xx.x)
– R911172135
2)
–
X2N
3)
Cable set;
shielded, 5-pole, for connecting
Rexroth pressure sensors,
typeHM20,A coding
PUR/PVC, straight connectorM12, on straight
socketM12, line cross-section 0.34mm
2
, 0.6 m
– R901111709 –
PUR/PVC, straight connectorM12, on straight
socketM12, line cross-section 0.34mm
2
, 1.0 m
– R901111712 –
PUR/PVC, straight connectorM12, on straight
socketM12, line cross-section 0.34mm
2
, 2.0 m
– R901111713 –
Cable set;
shielded, 5-pole,A coding
Straight connectorM12, on free line end,
line cross-section 0.34mm
2
, 1.5 m
– R901111752 –
Straight connectorM12, on free line end,
line cross-section 0.34mm
2
, 3.0 m
– R901111754 –
Straight connectorM12, on free line end,
line cross-section 0.34mm
2
, 5.0 m
– R901111756 –
Straight connectorM12, on free line end,
line cross-section 0.34mm
2
, 10.0 m
– R913005147 –
Notice:
▶ Tighten the M12 connector with amanual torque wrench
by 1Nm.
▶ Self-locking M12 cables must be used.
▶ It must be ensured that cables are secured without
radial force.
▶ All cables connected to “XH1”, “X7E1” and “X7E2” must be
bundled in awire harness after 20cm the latest. The wire
harness must be fixed after further 20 … 30cm. Make sure
that there is no relative motion between the fixation and
the valve.
▶ Before the fixation point, there must not be any cable loops.
▶ In general, the information on installation provided by
the cable manufacturers must be observed.
▶ Respectively, the cable of “X2N” (if used) is also fixed
as described above.
▶ For further information, seeoperating instructions 29391-B
1)
Additional indication of typedesignation RKB0040/xx.x
2)
Additional indication of typedesignation RKB0044/xx.x
3)
Only with connection of anexternal sensor, typeHM20