Assembly, commissioning, maintenance
Installation
▶ The max. operating pressure of the system must not
exceed the max. admissible operating pressure of the
filter (see type plate).
▶ During assembly of the filter (see also chapter “Tighten-
ing torque””), the flow direction (direction arrows) and
the required servicing height of the filter element (see
chapter “Dimensions”) are to be considered.
▶ Easy filter element exchange is guaranteed in the instal-
lation position filter bowl vertically downwards. The
maintenance indicator must be arranged so it is easily
viewed in operation.
▶ Remove the plastic plugs in the filter inlet and outlet.
▶ Ensure that the system is assembled without tension
stress.
▶ The optional electronic maintenance indicator is con-
nected via the electronic switching element with 1 or 2
switching points, which is attached to the mechanical
optical maintenance indicator and held by means of the
locking ring.
Commissioning
▶ Commission the system.
Notice:
There is no bleed function provided at the filter.
Maintenance
▶ If at operating temperature, the red indicator pin
reaches out of the mechanical optical maintenance
indicator and/or if the switching process in the elec-
tronic switching element is triggered, the filter element
is contaminated and needs to be replaced and cleaned
respectively.
More details see data sheet 51450
▶ The material number of the corresponding replacement
filter element is indicated on the name plate of the
complete filter. It must comply with the material num-
ber on the filter element.
▶ Decommission the system.
▶ The operating pressure is to be release on the system
side.
Notice:
There is no bleed function provided at the filter.
▶ Via the drain screw (from size 0160 fitted by default),
the oil on the dirt side can be drained.
▶ Screw off the filter bowl.
▶ Remove the filter element from the spigot by rotating it
slightly.
▶ Clean the filter components, if necessary.
▶ Check the seals at the filter bowl for damage and renew
them, if necessary.
For suitable seal kits refer to chapter “Spare parts”.
▶ Filter elements made of wire mesh can be cleaned. For
detailed cleaning instructions refer to data sheet 51420.
▶ Install the new or cleaned filter element on the spigot
again by slightly rotating it.
▶ The filter is to be assembled in reverse order.
▶ The torque specifications (Tightening torques chapter)
are to be observed.
▶ Commission the system.
Notices:
▶ All maintenance of the filter should be performed by
trained specialists.
▶ Proper function and safety are only guaranteed if
original Bosch Rexroth filter elements and spare parts
are used.
▶ Warranty becomes void if the delivered item is
changed by the ordering party or third parties or
improperly mounted, installed, maintained, repaired,
used or exposed to environmental condition that do
not comply with the installation conditions.
WARNING!
▶ Assemble and disassemble only with depressurized system!
▶ Filter is pressurized!
▶ Remove the filter bowl only if it is not under pressure!
▶ Do not exchange the optical/mechanical maintenance
indicator while the filter is under pressure!
▶ If the flow direction is not considered during assem-
bly, the filter element will be destroyed. Particle
contaminates could enter the system and damage the
downstream components.