High-response directional cartridge valve | 2WRCE; 2WRCF 9/36
RE 29406, edition: 2025-10, Bosch Rexroth AG
Technical data
(For applications outside these parameters, please consult us.)
Hydraulic fluid Classification Suitable sealing
materials
Standards Datasheet
Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN51524 90220
Bio-degradable
▶ Insoluble in water HETG FKM
ISO15380
90221HEES FKM
▶ Soluble in water HEPG FKM ISO15380
Flame-resistant ▶ Water-free HFDU (glycol base) FKM
ISO 12922 90222HFDU (ester base) FKM
HFDR FKM
▶ Containing water HFC (Fuchs: Hydrotherm46M,
Renosafe500;
Petrofer: UltraSafe 620;
Houghton: Safe620;
Union: CarbideHP5046)
NBR
ISO 12922 90223
Important information on hydraulic uids:
▶ For further information and data on the use of other hydraulic
fluids, please refer to the datasheets above or contact us.
▶ There may be limitations regarding the technical valve data
(temperature, pressure range, life cycle, maintenance intervals,
etc.).
▶ The ignition temperature of the hydraulic fluid used must be
50K higher than the maximum surface temperature.
▶ Bio-degradable and flame-resistant–containing water: If
components with galvanic zinc coating (e.g.version"J3" or "J5")
or parts containing zinc are used, small amounts of dissolved
zinc may get into the hydraulic system and cause accelerated
aging of the hydraulic fluid. Zinc soap may form as achemical
reaction product, which may clog filters, nozzles and solenoid
valves–particularly in connection with local heat input.
▶ Flame-resistant–containing water:
– Due to an increased cavitation tendency with the use of
HFChydraulic fluids, the life cycle of the component may be
reduced by up to 30% as compared to use with HLP mineral oil.
In order to reduce the cavitation effect, it is recommended–if
possible, specific to the installation–to back up the return
flow pressure in portsT to approx.20% of the pressure
differential at the component.
– Dependent on the hydraulic fluid used, the maximum
ambient and hydraulic fluid temperature must not exceed
50°C. In order to reduce the heat input into the component,
the command value profile is to be adjusted for proportional
and high-response valves.
Static/dynamic
Size 32 40 50 63 80 100
Hysteresis % <0.2
Range of inversion % <0.1
Response sensitivity % <0.1
Zero point calibration ±1 (ex works)
Temperature drift
when changing
▶ Hydraulic fluid temperature %/10 K ≤0.3
▶ Pilot pressure inX %/100bar ≤0.2
Step response time according to ISO 10770-1
11)
ms 11 14 24 24
12)
26
12)
33
12)
Reaching of the preferred position
13)
ms 52…38 62…48 130 … 85 160…90 335 … 198 612 … 356
11)
Without shut-off valve; 10 ... 100%, pilot pressure 150bar
12)
Step response times for standard delivery. By activating the pilot
pressure-dependent control parameters, dynamics are further
increased, especially in the small signal range (see characteristic
curves on pages 21, 23 and 25). These must be enabled
once via the "IndraWorks" commissioning software (on request).
13)
With shut-off valve "WK" and "WL", pilot pressure 100…315bar