RE 29403, edition: 2025-05, BoschRexrothAG
Features
2-way cartridge valve
Integrated pilot control valve in 3/2-way version
Robust
Pressure resistant to 420 bar
High vibration resistance
Precise
High response sensitivity, low hysteresis
Normalized
Installation dimensions according to ISO7368
Flexible
Suitable for controlling position, pressure and
velocity
Safe
Fail-safe position of the pilot control valve in case of
error; control spool of the main stage in seat position
CE conformity according to EMC Directive 2014/30/EU.
UKCA conformity according to Electromagnetic
Compatibility Regulations SI 2016/1091
Contents
Features 1
Ordering code 2, 3
Symbols 3
Function, section 4
Technical data 5…9
Block diagram/controller function block 10, 11
Electrical connections and assignment 12
Characteristic curves 13…22
Dimensions 23…25
Installation bore 26
Accessories 27
Further information 27
Size16…50
Component series 1X
Maximum operating pressure 420bar
Maximum ow 1500l/min (∆p=5bar)
H8069
Proportional directional cartridge valve,
pilot-operated, with integrated electronics
(OBE) or external control electronics
Type2WFC and 2WFCE
RE 29403 
Edition: 2025-05
Replaces: 2023-11
Inhalt
Features 1
Contents 1
Ordering code 2
Ordering code 3
Symbols 3
Function, section 4
Technical data
(For applications outside these values, please consult
us.) 5
Technical data
(For applications outside these values, please consult
us.) 6
Technical data
(For applications outside these values, please consult
us.) 7
Technical data
(For applications outside these values, please consult
us.) 8
Technical data
(For applications outside these values, please consult
us.) 9
Block diagram/controller function block: Version "A1" 10
Block diagram/controller function block: Version"B1" and
"G1" 11
Electrical connections and assignment 12
Characteristic curves: Size16
(measured with HLP46, ϑ
oil
= 40±5°C) 13
Characteristic curves: Size16
(measured with HLP46, ϑ
oil
= 40±5°C) 14
Characteristic curves: Size25
(measured with HLP46, ϑ
oil
= 40±5°C) 15
Characteristic curves: Size25
(measured with HLP46, ϑ
oil
= 40±5°C) 16
Characteristic curves: Size32
(measured with HLP46, ϑ
oil
= 40±5°C) 17
Characteristic curves: Size32
(measured with HLP46, ϑ
oil
= 40±5°C) 18
Characteristic curves: Size40
(measured with HLP46, ϑ
oil
= 40±5°C) 19
Characteristic curves: Size40
(measured with HLP46, ϑ
oil
= 40±5°C) 20
Characteristic curves: Size50
(measured with HLP46, ϑ
oil
= 40±5°C) 21
Characteristic curves: Size50
(measured with HLP46, ϑ
oil
= 40±5°C) 22
Dimensions: Integrated electronics (OBE) "E"
(dimensions inmm) 23
Dimensions: External control electronics
(dimensions inmm) 24
Dimensions 25
Installation bore
(dimensions in mm) 26
Accessories (separate order) 27
Further information 27
Notes 28
2/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Ordering code
01 2 main ports 2
02 Pilot-operated proportional directional valve (cartridge valve) WFC
03 External control electronics no code
Integrated electronics (OBE) E
04 Size16 16
Size25 25
Size32 32
Size40 40
Size50 50
05 Seat control spool S
Nominal ow (Δp=5bar)
06 – Size16
125l/min
1)
125
160l/min
2)
160
– Size25
220l/min
1)
220
330l/min
2)
330
– Size32
320l/min
1)
320
650l/min
2)
650
– Size40
500l/min
1)
500
940l/min
2)
940
– Size50
1000l/min
1)
1000
1500l/min
2)
1500
Flow characteristic
07 Linear L
08 Component series 10…19(10…19: unchanged installation and connection dimensions) 1X
Seal material (observe compatibility of seals with hydraulic uid used, seepage7)
09 NBR seals M
FKM seals V
Electrical connection (external control electronics)
10 Connector 3-pole (2+PE) according to EN175301-803 K4
3; 4)
11 External control electronics no code
Supply voltage 24VDC (integrated electronics (OBE) "E") 24
Electrical interface (integrated electronics (OBE) "E")
12 Command value 0.5…10VDC A1
3; 5)
Command value 0…10VDC B1
3; 6)
Command value 4…20mA G1
3; 6)
13 Further details in the plain text *
01 02 03 04 05 06 07 08 09 10 11 12 13
2 WFC S L 1X / / *
Proportional directional cartridge valve | 2WFC; 2WFCE 3/28
RE 29403, edition: 2025-05, BoschRexrothAG
Ordering code
Symbols
1)
Control spool linear (standard)
2)
Control spool linear – progressive
3)
Mating connectors, separate order, seepage27 and
datasheet08006.
4)
External control electronics, seepage27.
Simplied
External control electronics "2WFC" Integrated electronics (OBE) "2WFCE"
B
AX Y
B
AX Y
Detailed
Internal pilot oil supply (A→B) Internal pilot oil supply (B→A)
XA
BY
XA
BY
Notes:
External pilot oil supply (application-dependent possible)
A→B (pressure in X ≥ pressure in A)
B→A (pressure in X ≥ pressure in B)
Representation accordingtoISO1219-1.
5)
Switch-on of the position control at command value ≥0.5…10V;
valve seat position without position control at command value
≤0.3V (seepage10).
6)
Switch-on of the position control if enable is set; valve seat
position without position control by switching off the enable
(see page 11).
43
1
XY
2
A
B
Proportional directional cartridge valve | 2WFC; 2WFCE 4/28
RE 29403, edition: 2025-05, BoschRexrothAG
Set-up
The pilot-operated proportional directional cartridge
valve type2WFC(E) basically consists of:
Cover(1)
Main stage(2)
Pilot control valve with proportional solenoid(3)
Integrated electronics with position transducer and
analog interface(4) or external control electronics as
module amplier
Function, section
Function
The electronics (integrated or external) compare the
specified command value to the position actual value of
the control spool of the main stage(2). In case of control
deviations, the solenoid of the pilot control valve(3)
is activated. In this way, the control spool is adjusted.
Depending on the control deviation, the control chamber
of the main stage(2) is either pressurized with pilot oil
(the main stage closes) or unloaded (the main stage
opens). Stroke and orifice cross-section are controlled
proportionally to the command value until the control
deviation is remedied.
For proper function, the following has to be observed:
Direction of owA →B (X connected to A)
Direction of owB →A (X connected to B)
PortY depressurized to the tank
Pressure in port Y acts against the pressure in
ports A and B to open the main stage.
Pressure in ports A and B simultaneously acts against
pilot pressure X
Observe the leakage ow at the pilot control valve
Failure of supply voltage
If the minimum supply voltage fails or is fallen below, the
enable is disconnected (only interfaces "B1" and "G1")
and in case of acable break of the solenoid conductor,
the electronics will de-energize the solenoid of the pilot
control valve(3). The control spool of the main stage(2)
moves securely to its seat using the pressure available at
port X and the force of the main stage spring and blocks
the flow betweenA and B.
Notice:
Pilot oil must be present before the electronics are
switched on (also in case of error or emergency stop).
Type2WFCE …
Proportional directional cartridge valve | 2WFC; 2WFCE 5/28
RE 29403, edition: 2025-05, BoschRexrothAG
Technical data
(For applications outside these values, please consult us.)
General
Size NG 16 25 32 40 50
Type of connection Cartridge valve
Weight Type2WFC kg 3.3 4.4 5.6 7.7 10.3
Type2WFCE kg 3.5 4.6 5.8 7.9 10.5
Installation position Any
Ambient temperature range °C –20…+60
Maximum storage time Years 1 (if the storage conditions are observed, refer to the operating
instructions 07600-B)
Maximum relative humidity (no condensation) % 95
Protection class according to EN60529 IP65 (if suitable and correctly mounted mating connectors
are used)
Maximum surface temperature °C 150
MTTF
D
values according to ENISO13849 Years 75 (for further details seedatasheet08012)
Sine test according to EN 60068-2-6 10…2000Hz / maximum of 10 g / 10 cycles / 3 axes
Noise test according to EN60068-2-64 20…2000 Hz / 10 g
RMS
/ 30g peak / 30 min. / 3 axes
Transport shock according to EN60068-2-27 15g / 11ms / 3 shocks / 3 axes
Conformity CE according to EMC Directive 2014/30/EU,
tested according to
EN61000-6-2 and EN61000-6-3
UKCA according to EMC Directive
SI 2016/1091, tested according to
EN61000-6-2 and EN61000-6-3
RoHS Directive 2015/65/EU
1)
1)
The product fulfills the substance requirements of the
RoHS Directive 2015/65/EU.
6/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
2)
Pressure in port Y acts against the pressure in ports A and B to
open the main stage.
3)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents
faults and simultaneously increases the life cycle of the
components.
4)
Flow for deviating ∆p:
q
x
= q
Vnom
x
∆p
x
5
5)
Flow value simulated with port A = D3 max and port B = D4 max
(see page 26).
6)
Recommendation in order not to exceed an average flow velocity
of 30m/s with maximum diameters of channels A and/or T.
However, the valve can also be reliably operated at higher
volume flows.
7)
Control spool regulated, positive overlap.
8)
Pin 3:
Version "B1" and "G1": Enable not set
Version "A1": Command value <0.3V
9)
Observe the leakage flow at the pilot control valve.
10)
A minimum leakage flow X→B and B→X up to 0.03l/min
is possible via the control spool clearance at the main stage.
Hydraulic
Maximum operating
pressure
PortA, B bar 420
PortY
2)
bar 100
Minimum operating
pressure
Port A (A→B)
2)
bar 12
Port B (B→A)
2)
bar 20
Hydraulic fluid Seetable on page7
Hydraulic fluid temperature range (flowing) °C –20…+70
Viscosity range Recommended mm
2
/s 20…100
Maximum admissible mm
2
/s 15…380
Maximum admissible degree of contamination of the
hydraulic fluid; cleanliness class according to ISO4406(c)
Class 18/16/13
3)
Rated flow
(∆p=5bar
4)
)
Linear l/min 125 220 320 500 1000
Linear–progressive l/min 160 330 650 940 1500
Maximum flow
5; 6)
Linear l/min 350 600 1000 1500 3000
Linear–progressive l/min 400 800 2000 3000 4500
Leakage flow
7)
Pilot control valve (at 100bar) l/min <0.15 <0.2 <0.2 <0.4 <0.4
Main stage
"B2" (0V), "G1" (4mA) l/min 2 2 2 3 4
"A1" (0.5V) l/min 3 4 4 6 7
Electric shut-off
8; 9; 10)
A→B blocked without leakage (seat control spool)
B→A blocked (seat control spool)
Maximum pilot pressure PortX bar 420
Pilot flow l/min 3 5 7 9 9
Technical data
(For applications outside these values, please consult us.)
Proportional directional cartridge valve | 2WFC; 2WFCE 7/28
RE 29403, edition: 2025-05, BoschRexrothAG
Technical data
(For applications outside these values, please consult us.)
Hydraulic fluid Classification Suitable sealing
materials
Standards Datasheet
Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN51524 90220
Bio-degradable
insoluble in water HETG FKM
ISO15380
90221HEES FKM
soluble in water HEPG FKM ISO15380
Flame-resistant water-free HFDU (glycol base) FKM
ISO12922 90222HFDU (ester base) FKM
HFDR FKM
containing water HFC (Fuchs: Hydrotherm46M,
Renosafe500;
Petrofer: UltraSafe 620;
Houghton: Safe620;
Union: CarbideHP5046)
NBR
ISO12922 90223
Important information on hydraulic uids:
For further information and data on the use of other hydraulic fluids,
please refer to the datasheets above or contact us.
There may be limitations regarding the technical valve data
(temperature, pressure range, life cycle, maintenance intervals,
etc.).
The ignition temperature of the hydraulic fluid used must be
50K higher than the maximum surface temperature.
Bio-degradable and flame-resistant–containing water:
If components with galvanic zinc coating (e.g.version"J3" or "J5")
or parts containing zinc are used, small amounts of dissolved zinc
may get into the hydraulic system and cause accelerated aging of
the hydraulic fluid. Zinc soap may form as achemical reaction
product, which may clog filters, nozzles and solenoid
valves–particularly in connection with local heat input.
Flame-resistant–containing water:
Due to an increased cavitation tendency with the use of
HFChydraulic fluids, the life cycle of the component
may be reduced by up to 30% as compared to use with
HLP mineral oil. In order to reduce the cavitation effect,
it is recommended–if possible, specific to the
installation–to back up the return flow pressure in portsT
to approx.20% of the pressure differential at the component.
Dependent on the hydraulic fluid used, the maximum ambient
and hydraulic fluid temperature must not exceed 50°C.
In order to reduce the heat input into the component,
the command value profile is to be adjusted for proportional
and high-response valves.
Static/dynamic
Hysteresis % <0.2
Range of inversion % <0.1
Response sensitivity % <0.1
Temperature drift %/40 K <1
Zero point calibration % ±1 (ex works)
8/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Electrical, integrated electronics (OBE) – interface "A1"
Supply voltage Nominal value VDC 24
Minimum VDC 18
Maximum VDC 36
Maximum residual ripple V 2.5 (comply with the absolute supply voltage limit values)
Maximum power consumption VA 50
Current consumption
during operation
11)
Rated current A 2
Impulse current
A 3
Fuse protection, external A
T
2.5 (time-lag)
Relative duty cycle time according to VDE 0580 % S1 (continuous operation)
Functional ground and screening See pin assignment, page 12
Maximum voltage of the differential inputs against 0V DB; E→B (max. 18V)
Command value
(differential amplier)
Measurement range V 0 … 10
Input resistance >100
Actual value
(test signal)
Output range V 0…10
12)
Minimum load impedance kΩ >1
Technical data
(For applications outside these values, please consult us.)
11)
The making current peak is usually higher (depending on
power supply unit, supply line, and capacities).
12)
Command value <0.3V: –3…–5V (seat position)
Proportional directional cartridge valve | 2WFC; 2WFCE 9/28
RE 29403, edition: 2025-05, BoschRexrothAG
Electrical, integrated electronics (OBE) – Interface "B1"
Supply voltage Nominal value VDC 24
Minimum VDC 19
Maximum VDC 36
Maximum residual ripple V 2.5
Maximum power consumption VA 50
Current consumption
during operation
11)
Rated current A 2
Impulse current
A 3
Fuse protection, external A
T
2.5 (time-lag)
Relative duty cycle time according to VDE 0580 % S1 (continuous operation)
Functional ground and screening See pin assignment, page 12
Maximum voltage of the differential inputs against 0V 42; 5→2 (max. 18V)
Command value
(differential amplier)
Measurement range V 0 … 10
Input resistance >100
Actual value
(test signal)
Output range V 0…10 (without enable negative −3…−5)
Minimum load impedance kΩ >1
Enable Low level range V −3…5
High level range V >12
Maximum current consumption at
high level
mA 5
Valve ready for
operation (output)
Low level range V <8
High level range V >16
Current carrying capacity mA 50
Inductive load admissible Yes
Technical data
(For applications outside these values, please consult us.)
Electrical, integrated electronics (OBE) – interface "G1"
Supply voltage Nominal value VDC 24
Minimum VDC 19
Maximum VDC 36
Maximum residual ripple V 2.5
Maximum power consumption VA 50
Current consumption
during operation
11)
Rated current A 2
Impulse current
A 3
Fuse protection, external A
T
2.5 (time-lag)
Relative duty cycle time according to VDE 0580 % S1 (continuous operation)
Functional ground and screening See pin assignment, page 12
Maximum voltage of the differential inputs against 0V 42; 5→2 (max. 18V)
Command value Input current range mA 4…20
Input resistance 200
Actual value
(test signal)
Output range mA 4…20 (without enable 2.7…1)
Maximum load 500
Enable Low level range V −3…5
High level range V >12
Maximum current consumption at
high level
mA 5
Valve ready for
operation (output)
Low level range V <8
High level range V >16
Current carrying capacity mA 50
Inductive load admissible Yes
11)
The making current peak is usually higher (depending on
power supply unit, supply line, and capacities).
D
E
U/I
U
X
Y
U
I
VS
F
C
A
B
U/I
U
DC
DC
&
24
V
0 V
+15 V, 10 mA
–Vref = -3,3 V
+7,5…8 V, 50 mA
+3,3 V, 10 mA
– 7,5…8 V, 50 mA
10/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Switch-on procedure/fault behavior
Pilot oil must be present.
After applying the supply voltage of 24V, the electronics are ready
for operation provided that the following conditions are met:
Supply voltage U
B
> 18 VDC
Connection to solenoid not interrupted
Command value line not interrupted
Actual value output signals
PinF:
0.35…10V corresponds to 0…100% valve opening
Actual value <0.3V Control spool in seat position
Block diagram/controller function block: Version "A1"
Command value
Short-circuit of solenoid
Cable break
of solenoid
Amplier
differential
Position
transducer
Protection
circuit
Protection
circuit
Protection
circuit
Inverse-
polarity
protection
Actual value
output
Controller
Demodulator
Sine
oscillator
Output stage
Command
value enable
Actual value
Reference potential
command value
Reference potential
actual value
Supply voltage
Notes:
Opening direction: Valve active if command value ≥0.5V
Closing direction: Valve deactivated if command value ≤0.3V
(control spool in seat position)
Command value 0.4V: Valve in positive overlap, but already
regulated.
Command value Actual value Symbol Feature
0…0.3V −1…−5V
A→B; B→A closed
0.35…0.5V 0.35…0.5V
Positive overlap;
leakage A→B; B→A
0.5…10V 0.5…10V
A→B; B→A
U/I
U
U
I
VS
U/I
U
DC
DC
+15 V, 10 mA
–Vref = -3,3 V
M0
+7,5…8 V, 50 mA
+3,3 V, 10 mA
–7,5…8 V, 50 mA
&
24
V
0 V
4
5
11
6
7
1
10
9
8
2
3
Proportional directional cartridge valve | 2WFC; 2WFCE 11/28
RE 29403, edition: 2025-05, BoschRexrothAG
Command value
Enable input
Short-circuit of solenoid
Cable break
of solenoid
Amplier
differential
Position transducer
Protection
circuit
Protection
circuit
Protection
circuit
Inverse-
polarity
protection
Actual value
output
Controller
Demodulator
Sinus oscillator
Output stage
Cable break
"G1"
Enable
Actual value
Ready for operation
Not assigned
Not assigned
Not assigned
Reference potential
command value
Reference potential actual value
Supply voltage
Block diagram/controller function block: Version"B1" and "G1"
Switch-on procedure/fault behavior
Pilot oil must be present.
After applying the supply voltage of 24V, the electronics are
ready for operation provided that the following conditions are met:
Supply voltage U
B
> 18 VDC
Connection to solenoid not interrupted
Command value line not interrupted and command value
>2.7mA ("G1" version only)
Actual value output signals
Pin6:
Version "B1"
0…10V corresponds to 0…100% valve opening
Without enable if negative actual value -1…-5V:
Control spool in seat position
Version "G1"
4…20mA corresponds to 0…100% valve opening;
control spool in seat position if actual value <2.7mA
Notes:
Opening direction: Valve active if enable pin3 is set;
command value ≥0V ("B1") or ≥4mA ("G1")
Closing direction: Valve deactivated if enable pin3 is not set;
switching off possible if command value 0…10V or
4…20mA.
Command value 0V ("B1") or 4mA ("G1"): Valve in positive
overlap, but already regulated.
Command value Actual value Enable Symbol Feature
−1…−5V;
2.7…1mA
Inactive
A→B; B→A closed
0V;
4mA
0V;
4mA
Active
Positive overlap;
leakage A→B; B→A
0…10V;
4…20mA
0…10V;
4…20mA
Active
A→B; B→A
A
B
C
D
E
F
PE
XH1
1
2
3
4
5
6
PE
11
10
9
8
7
XH2
12/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Notice:
Mating connectors, separate order, seepage27 and
datasheet08006.
Pin Interface assignment
"A1"
A Supply voltage
B GND
C Reference potential actual value
D Command value
E Reference potential command value
F Actual value
FE
Functional ground (directly connected to the valve housing)
Electrical connections and assignment
Pin
Core marking Interface assignment
Cable, one-part
1)
Cable, split
2)
"B1" "G1"
1 1 1 Supply voltage Supply voltage
2 2 2 GND GND
3 3 White Enable input Enable input
4 4 Yellow Command value Command value
5 5 Green Reference potential command value Reference potential command value
6 6 Violet Actual value Actual value
7 7 Pink Reference potential actual value Reference potential actual value
8 8 Red Not assigned Not assigned
9 9 Brown Not assigned Not assigned
10 10 Black Not assigned Not assigned
11 11 Blue Switching output 24V – fault-free operation (supply voltage -1V) /
error (0V) or power circuit signal)
PE Green-yellow Green-yellow Functional ground (connected directly to metal housing)
Connector pin assignment "XH2", 11-pole+PE according to EN175201-804
1)
Core marking of the connection lines for mating connector
with cable set (seeaccessories, page27, material numbers
R901268000, R901272854, R901272852)
2)
Core marking of the connection lines for mating connector
with cable set (seeaccessories page27, material numbers
R900884671, R900032356, R900860399)
Connector pin assignment "XH1", 6-pole+PE according to DIN43563
Connection cable:
Up to 20m cable length typeLiYCY7x0.75mm
2
Up to 40m cable length typeLiYCY7x1.0mm
2
EMC-compliant installation:
Apply screening to both line ends
Use metal mating connector (seepage27)
Alternatively up to 30m cable length admissible
Apply screening on supply side
Plastic mating connector (seepage27) can be used
0
0
50
100
150
200
250
300
350
400
12345678910
1
2
3
0
0
50
100
150
200
250
300
350
400
12345678910
1
2
3
Proportional directional cartridge valve | 2WFC; 2WFCE 13/28
RE 29403, edition: 2025-05, BoschRexrothAG
Characteristic curves: Size16
(measured with HLP46, ϑ
oil
= 40±5°C)
Flow-signal-function
Version "125" (A→B; B→A; linear)
Version "160" (A→B; B→A; linear–progressive)
Command value inV →
Command value inV →
Flow in l/min Flow in l/min
1
Pressure differential 20bar
2
Pressure differential 10bar
3 Pressure differential 5bar
Notice:
Typical characteristic curves which are subject to tolerance
variations.
1 Signal 100±5
%
2 Signal 90±10
%
3 Signal 75±25
%
110203040
50 60 80
100
-40
-30
-60
-90
-120
-150
-180
-210
-240
-270
-35
-30
-25
-20
-15
-10
-5
0
5
1
2
3
2
3
0
10
0
20
30
40
50
60
70
80
90
100
200 400 600 800 1000 0 200 400 600 800 1000
0 – 100 – 0
10 – 90 – 10
25 – 75 – 25
14/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Characteristic curves: Size16
(measured with HLP46, ϑ
oil
= 40±5°C)
Transition function with stepped electrical input signals
(p
A
= p
B
= 100bar; port B closed; actuating time depending on port A, B, X and Y)
Frequency response (p
A
=100bar)
Time in ms
Signal change in %
Frequency inHz →
Stroke in % Amplitude ratio in dB
Phase angle in ° →
Notice:
Typical characteristic curves which are subject to tolerance
variations.
0
0
50
100
150
200
250
300
350
400
12345678910
1
2
3
0
0
100
200
300
400
500
600
700
800
12345678910
1
2
3
Proportional directional cartridge valve | 2WFC; 2WFCE 15/28
RE 29403, edition: 2025-05, BoschRexrothAG
Characteristic curves: Size25
(measured with HLP46, ϑ
oil
= 40±5°C)
Flow-signal-function
Version "220" (A→B; B→A; linear)
Version "330" (A→B; B→A; linear–progressive)
Command value inV →
Command value inV →
Flow in l/min Flow in l/min
1
Pressure differential 20bar
2
Pressure differential 10bar
3 Pressure differential 5bar
Notice:
Typical characteristic curves which are subject to tolerance
variations.
1 Signal 100±5
%
2 Signal 90±10
%
3 Signal 75±25
%
110203040
50 60 80
100
-40
-35
-30
-25
-20
-15
-10
-5
0
5
-30
-60
-90
-120
-150
-180
-210
-240
-270
1
2
3
2
3
0
10
0
20
30
40
50
60
70
80
90
100
200 400 600 800 1000 0 200 400 600 800 1000
0 – 100 – 0
10 – 90 – 10
25 – 75 – 25
16/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Characteristic curves: Size25
(measured with HLP46, ϑ
oil
= 40±5°C)
Transition function with stepped electrical input signals
(p
A
= p
B
= 100bar; port B closed; actuating time depending on port A, B, X and Y)
Frequency response (p
A
=100bar)
Time in ms
Signal change in %
Frequency inHz →
Stroke in % Amplitude ratio in dB
Phase angle in ° →
Notice:
Typical characteristic curves which are subject to tolerance
variations.
0
0
100
200
300
700
400
500
600
12345678910
1
2
3
0
0
200
400
600
800
1000
1200
1400
12345678910
1
2
3
Proportional directional cartridge valve | 2WFC; 2WFCE 17/28
RE 29403, edition: 2025-05, BoschRexrothAG
Characteristic curves: Size32
(measured with HLP46, ϑ
oil
= 40±5°C)
Flow-signal-function
Version "320" (A→B; B→A; linear)
Version "650" (A→B; B→A; linear–progressive)
Command value inV →
Command value inV →
Flow in l/min Flow in l/min
1
Pressure differential 20bar
2
Pressure differential 10bar
3 Pressure differential 5bar
Notice:
Typical characteristic curves which are subject to tolerance
variations.
1 Signal 100±5
%
2 Signal 90±10
%
3 Signal 75±25
%
110203040
50 60 80
100
-40
-35
-30
-25
-20
-15
-10
-5
0
5
-30
-60
-90
-120
-150
-180
-210
-240
-270
1
2
3
2
3
0
10
0
20
30
40
50
60
70
80
90
100
200 400 600 800 1000 0 200 400 600 800 1000
0 – 100 – 0
10 – 90 – 10
25 – 75 – 25
18/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Characteristic curves: Size32
(measured with HLP46, ϑ
oil
= 40±5°C)
Transition function with stepped electrical input signals
(p
A
= p
B
= 100bar; port B closed; actuating time depending on port A, B, X and Y)
Frequency response (p
A
=100bar)
Time in ms
Signal change in %
Frequency inHz →
Stroke in %
Amplitude ratio in dB
Phase angle in ° →
Notice:
Typical characteristic curves which are subject to tolerance
variations.
0
0
200
400
600
1400
800
1200
1000
12345678910
1
2
3
0
0
200
400
600
800
1000
1200
1400
1600
1800
2200
2000
12345678910
1
2
3
Proportional directional cartridge valve | 2WFC; 2WFCE 19/28
RE 29403, edition: 2025-05, BoschRexrothAG
Characteristic curves: Size40
(measured with HLP46, ϑ
oil
= 40±5°C)
Flow-signal-function
Version "500" (A→B; B→A; linear)
Version "940" (A→B; B→A; linear–progressive)
Command value inV →
Command value inV →
Flow in l/min
Flow in l/min
1
Pressure differential 20bar
2
Pressure differential 10bar
3 Pressure differential 5bar
Notice:
Typical characteristic curves which are subject to tolerance
variations.
1 Signal 100±5
%
2 Signal 90±10
%
3 Signal 75±25
%
110203040
50 60 80
100
-40
-35
-30
-25
-20
-15
-10
-5
0
5
-30
-60
-90
-120
-150
-180
-210
-240
-270
1
2
3
2
3
0
10
0
20
30
40
50
60
70
80
90
100
200 400 600 800 1000 0 200 400 600 800 1000
0 – 100 – 0
10 – 90 – 10
25 – 75 – 25
20/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Characteristic curves: Size40
(measured with HLP46, ϑ
oil
= 40±5°C)
Transition function with stepped electrical input signals
(p
A
= p
B
= 100bar; port B closed; actuating time depending on port A, B, X and Y)
Frequency response (p
A
=100bar)
Time in ms
Signal change in %
Frequency inHz →
Stroke in %
Amplitude ratio in dB
Phase angle in ° →
Notice:
Typical characteristic curves which are subject to tolerance
variations.
0
0
200
400
600
800
1000
1200
1400
1600
1800
2000
12345678910
1
2
3
0
0
200
400
600
800
1000
1200
1400
1600
1800
2000
12345678910
1
2
3
Proportional directional cartridge valve | 2WFC; 2WFCE 21/28
RE 29403, edition: 2025-05, BoschRexrothAG
Characteristic curves: Size50
(measured with HLP46, ϑ
oil
= 40±5°C)
Flow-signal-function
Version "1000" (A→B; B→A; linear)
Version "1500" (A→B; B→A; linear–progressive)
Command value inV →
Command value inV →
Flow in l/min Flow in l/min
1
Pressure differential 20bar
2
Pressure differential 10bar
3 Pressure differential 5bar
Notice:
Typical characteristic curves which are subject to tolerance
variations.
1 Signal 100±5
%
2 Signal 90±10
%
3 Signal 75±25
%
110203040
50 60 80
100
-40
-35
-30
-25
-20
-15
-10
-5
0
5
-30
-60
-90
-120
-150
-180
-210
-240
-270
1
2
3
2
1
0
10
0
20
30
40
50
60
70
80
90
100
200 400 600 800 1000 0 200 400 600 800 1000
0 – 100 – 0
10 – 90 – 10
25 – 75 – 25
22/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Characteristic curves: Size50
(measured with HLP46, ϑ
oil
= 40±5°C)
Transition function with stepped electrical input signals
(p
A
= p
B
= 100bar; port B closed; actuating time depending on port A, B, X and Y)
Frequency response (p
A
=100bar)
Time in ms
Signal change in %
Frequency inHz →
Stroke in % Amplitude ratio in dB
Phase angle in ° →
Notice:
Typical characteristic curves which are subject to tolerance
variations.
5.1
6
46
3.2
3.1
3.3
2
H2
H1
L3
7.1
1
H3
L4L5
L1
L2
B1
B2
YX
15
12
95
50
1.5
1.5
Proportional directional cartridge valve | 2WFC; 2WFCE 23/28
RE 29403, edition: 2025-05, BoschRexrothAG
Dimensions: Integrated electronics (OBE) "E"
(dimensions inmm)
Notice:
The dimensions are nominal dimensions which are subject to
tolerances.
Item explanations and valve mounting screws
seepage25.
NG B1 B2 H1 H2 H3 L1 L2 L3 L4 L5
16 65 47 286 215 56 32.5 83 175 42 50
25 85 47 302 231 72 42.5 93 175 42 40
32 100 315 244 85 50 100 175 42 33
40 125 335 264 105 62.5 125 190 45 20
50 140 352 281 122 70 140 190 38 12
4
67.2
3.2
3.1
3.3
7.3
2
5.2
1
H3
L4
L1
L2 B1
6
YX
1530L542
40
77
95
50
70
1.5
1.5
24/28
2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Dimensions: External control electronics
(dimensions inmm)
Notice:
The dimensions are nominal dimensions which are subject to
tolerances.
Item explanations and valve mounting screws
seepage25.
NG B1 H3 L1 L2 L4 L5
16 65 56 32.5 83 42 36
25 85 72 42.5 93 42 36
32 100 85 50 100 42 36
40 125 105 62.5 125 45 42
50 140 122 70 140 38 46.5
Proportional directional cartridge valve | 2WFC; 2WFCE 25/28
RE 29403, edition: 2025-05, BoschRexrothAG
Dimensions
1 Cover
2 Main stage
3.1 Name plate NG16
3.2 Name plate NG25…40
3.3 Name plate NG50
4 Pilot control valve with proportional solenoid
5.1 Integrated electronics with position transducer and analog
interface
5.2 External control electronics with position transducer.
Mating connectors for valves with "M12" connector
(separate order, seepage27 and datasheet08006)
Valve mounting screws (separate order)
Size Quantity Hexagon socket head cap screws Material number
16 4 ISO 4762 - M8 x 30 - 10.9-Zn/nc/480h/C
Tightening torque M
A
=30Nm±10%
R913014759
or
4 ISO 4762 - M8 x 30 - 10.9
Tightening torque M
A
=30Nm±10%
Not included in the
Rexroth delivery range
25 4 ISO 4762 - M12 x 40 - 10.9-Zn/nc/480h/C
Tightening torque M
A
=100Nm ±10%
R913015610
or
4 ISO 4762 - M12 x 40 - 10.9
Tightening torque M
A
= 110 Nm ±10%
Not included in the
Rexroth delivery range
32 4 ISO 4762 - M16 x 50 - 10.9-Zn/nc/480h/C
Tightening torque M
A
=240Nm ±10%
R913015664
or
4 ISO 4762 - M16 x 50 - 10.9
Tightening torque M
A
= 300 Nm ±10%
Not included in the
Rexroth delivery range
40, 50 4 ISO 4762 - M20 x 60 - 10.9-Zn/nc/480h/C
Tightening torque M
A
= 480 Nm ±10%
R913014726
or
4 ISO 4762 - M20 x 60 - 10.9
Tightening torque M
A
=590Nm ±10%
Not included in the
Rexroth delivery range
6 Space required for removing the mating connectors
7.1 Mating connectors/cable set for valves with round connector
(separate order, seepage27 and datasheet08006)
7.2 Mating connectors for valves with "K4" connector
(separate order, seepage27 and datasheet08006)
7.3 Mating connectors for sensors and valves with "M12x1"
connector(separate order, seepage27 and
datasheet08006)
Notice:
The tightening torques stated are guidelines when using
screws with the specified friction coefficients and when
using amanual torque wrench (tolerance±10%).
The specified tightening torques were calculated with the
total friction coefficient µ=0.09…0.14; adapt to modified
surfaces.
The tightening torque of the hexagon socket head cap screws
refers to the maximum operating pressure.
ØD3
ØD1H7
ØD4
max H1
H7
H5
R1
R2
H3H4
H2
ØD2H7
ØD7; T1
ØD6ØD6
4 x D5
L4
L1
L2
L3
L2
L6
L3
L1
L5
15°
15°
A
z
y
z
y
y
0.05 A
XA
B
2
3
A
X
Y
H6
Rz1max 8
y
=
0.0025- / Pt max 16
z
=
„A
„A
H8
D5
T1
D7H13
A - A
1
1
0.01/L1xL1
26/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG, RE 29403, edition: 2025-05
Installation bore
(dimensions in mm)
NG
Installation dimensions according to ISO7368
16 7368-06-1-1-16
25 7368-08-3-1-16
32 7368-09-5-1-16
40 7368-10-7-1-16
50 7368-11-9-1-16
Tolerances according to: General tolerances ISO 2768-mK
Valve mounting screws seepage25.
Installation dimensions according to ISO 7368
NG 16 25 32 40 50
ØD1H7 32 45 60 75 90
ØD2H7 25 34 45 55 68
ØD3max
1; 2)
16 25 32 40 50
ØD4
1; 2)
16 25 32 40 50
ØD4 max
1; 2)
25 32 40 50 63
ØD5 M8 M12 M16 M20 M20
ØD6 max 4 6 8 10 10
ØD7H13 4 6 6 6 8
H1 max 42.5 57 68.5 84.5 97.5
H2
+1
56 72 85 105 122
H3
+0.1
43 58 70 87 100
H4 min 11 12 13 15 17
H5 2 2.5 2.5 3 4
H6 min
1)
20 30 30 30 35
H7 2 2.5 2.5 3 3
H8
1)
20 25 35 45 45
L1 65 85 102 125 140
L2
±0.2
46 58 70 85 100
L3
±0.2
23 29 35 42.5 50
L4
±0.2
48 62 76 92.5 108
L5
±0.2
12.5 13 18 19.5 20
L6
±0.2
2 4 6 7.5 8
X 0.03 0.03 0.03 0.05 0.05
R1 max 2 2 2 4 4
R2 max
1)
1 1 1 1 1
T1 min 8 8 8 8 8
1)
Deviating from ISO7368
2)
Smaller bore causes areduction of the flow
1 Minimum dimension of surface nish "y"
2 PortB can be of any size within the range between H6min
and H1max. The durability of the block depends on its
material and geometry.
PortB may be at any position around the central axis of
port A. However, it must be observed that the mounting
bores and the control bores are not damaged.
3 Bore for locating pin
Proportional directional cartridge valve | 2WFC; 2WFCE 27/28
RE 29403, edition: 2025-05, BoschRexrothAG
Accessories (separate order)
Further information
Hydraulic uids on mineral oil basis Datasheet90220
Environmentally compatible hydraulic uids Datasheet90221
Flame-resistant, water-free hydraulic uids Datasheet90222
Flame-resistant hydraulic uids – containing water (HFAE, HFAS, HFB, HFC) Datasheet90223
Reliability characteristics according to ENISO13849 Datasheet08012
Hydraulic valves for industrial applications
Operating instructions 07600-B
Information on available spare parts www.boschrexroth.com/spc
External control electronics
Designation Version Material no. Datasheet
Modular design VT-MRPA1-2X Command value 0…10V R901476413 30220
Command value 4…20mA
R901476414
Mating connectors and cable sets
Item
1)
Designation Version Short designation Material
number
Data
sheet
7.1 Mating connector;
for valves with round connector,
6-pole+PE
Straight, metal, PG11 7PZ31...M R900223890 08006
Straight, plastic, PG11 7PZ31...K R900021267
Cable sets;
for valves with round connector,
6-pole+PE
Plastic, 3.0m 7PZ31 BF6 R901420483
Plastic, 5.0m R901420491
Plastic, 10.0m R901420496
Mating connector;
for valves with round connector,
11-pole+PE
Metal, shielded 12PN11…EMC R901268000
Plastic, two cable outlets 12PN11…2XD8 R900884671
Cable sets;
For valves with round connector,
11-pole+PE
Metal, shielded, 5.0 m 12PN11REFS EMC…BG R901420483
Metal, shielded, 20.0 m R901272852
Plastic, shielded, 5.0 m 12PN11REFF 2X… R900032356
Plastic, shielded, 20.0 m R900860399
7.2 Mating connector;
for valves with "K4" connector,
2-pole+PE, designA
Without circuitry, M16x1.5, 0…250V,
"a"
Z4 R901017010
Without circuitry, M16x1.5, 0…250V,
"b"
R901017011
7.3 Mating connectors;
for sensors and valves with "K24",
"K35" and "K72" connectors,
4-pole
Straight, PG7 4PZ24 R900773042
Straight, PG9 R900031155
Angled, PG7 R900779509
Angled, PG9 R900082899
1)
See dimensions on pages23 and 24.
BoschRexrothAG, RE 29403, edition: 2025-05
28/28 2WFC; 2WFCE | Proportional directional cartridge valve
BoschRexrothAG
Industrial Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 40 30 20
my.support@boschrexroth.com
www.boschrexroth.com
© All rights reserved to BoschRexrothAG, also regarding any disposal,
exploitation, reproduction, editing, distribution, as well as in the event of
applications for industrial property rights.
The data specied above only serve to describe the product. As our products
are constantly being further developed, no statements concerning a certain
condition or suitability for a certain application can be derived from our
information. The information given does not release the user from the
obligation of own judgment and verication. It must be remembered that our
products are subject to a natural process of wear and aging.
Notes