Information on available spare parts:
www.boschrexroth.com/spc
1/24
2- and 3-way high-response
cartridge valve
Type .WRCE.../P
Size 32, 40, and 50
Component series 2X
Maximum operating pressure 420 bar
Maximum flow 4500 l/min
RE 29137/08.13
Replaces: 10.05
Type 2WRCE...-2X/PType 3WRCE...-2X/P
Table of contents Features
Pilot operated 2-way high-response valve in block installa-
tion design
Suitable for position, pressure, force and velocity control
Pilot control valve (pilot):
Directly operated, electrically returned proportional valve
size 6, trimmed, closes the 2WRCE main stage in case
of power failure and applied pilot pressure, opens the
3WRCE main stage from A to T
Main stage: Position-controlled
Integrated control electronics (OBE)
Block installation:
Installation dimensions according to DIN ISO 7368
for 2WRCE
Typical applications:
•Presses
•Diecastingmachines
•Punchingaxes
More information:
Pilot control valve similar
•Type4WREE6,seedatasheet29061
Notice
Further variant type .WRCE…/S with servo pilot control,
seedatasheet29136
Contents Page
Features 1
Ordering code: Type 2WRCE 2
Ordering code: Type 3WRCE
1)
3
Symbols 4, 5
Set-up, function and section 6, 7
Technical data 8 ... 11
Controlelectronics,blockdiagram 9,11
Electrical connection, mating connectors 12
Characteristic curves 13...19
Dimensions 20 ... 22
Installation dimensions 23
Project planning / maintenance instructions /
additional information 24
1)
The three-port valves must not be used for new projects.
See page 7.
Inhalt
Table of contents 1
Features 1
Ordering code: Type 2WRCE 2
Ordering code: Type 3WRCE – Not for new applications! (refer
to page 7) 3
Symbols: Type 2WRCE 4
Symbols: Type 3WRCE – Not for new applications! (refer to
page 7) 5
Set-up, function and section: Type 2WRCE 6
Set-up, function and section: Type 3WRCE
1) 7
Technical data: Type 2WRCE (For applications outside
these values, please contact us!) 8
Technical data: Type 2WRCE (for applications outside
thesevalues,pleasecontactus! 9
Technical data: Type 3WRCE
1)
(For applications outside
these values, please consult us!) 10
Technical data: Type 3WRC(E)
1)
(For applications out-
side these values, please consult us!) 11
Electrical connection, mating connectors 12
Mating connectors for shut-off valve according to DIN EN
175301-803 for connector "K4" 12
Characteristic curves (measured with HLP32,
oil
= 40 °C ±5
°C) 13
Characteristic curves (measured with HLP32,
oil
= 40 °C ±5
°C) 14
Characteristic curves (measured with HLP32,
oil
= 40 °C ±5
°C) 15
Characteristic curves (measured with HLP32,
oil
= 40 °C ±5
°C) 16
Characteristic curves (measured with HLP32,
oil
= 40 °C ±5
°C) 17
Characteristic curves (measured with HLP32,
oil
= 40 °C ±5
°C) 18
Characteristic curves (measured with HLP32,
oil
= 40 °C ±5
°C) 19
Dimensions: Types 2WRCE and 3WRCE
1)
, size 32 (dimensi-
ons in mm) 20
Dimensions: Types 2WRCE and 3WRCE
1)
, size 40 (dimensi-
ons in mm) 21
Dimensions: Types 2WRCE and 3WRCE
1)
, size 50 (dimensi-
ons in mm) 22
Installation dimensions according to DIN ISO 7368 (dimensions
in mm) 23
Accessories (not included in the scope of delivery) 24
Project planning / maintenance instructions / additional informa-
tion 24
2/24 Bosch Rexroth AG Hydraulics
.WRCE.../P RE 29137/08.13
2/2 directional valve = 2
Electrically operated high-response
valve for block installation with integrated
electronics (OBE) = WRCE
Size 32 = 32
Size 40 = 40
Size 50 = 50
Seat piston = S
Rated flow in l/min at 5 bar valve pressure drop
Size 32: 650 l/min linear
480 l/min with fine control range only ...S480R...
= 650
= 480
Size 40: 1000 l/min linear only ...S1000L...
700 l/min with fine control range only ...S700R...
= 1000
= 700
Size 50: 1600 l/min linear only ...S1600L...
1100 l/min with fine control range only ...S1100R...
= 1600
= 1100
Characteristic curve form
Linear = L
Linear with progressive fine control range = R
Componentseries20to29 = 2X
(20to29:Unchangedinstallationandconnectiondimensions)
Pilot control valve (pilot)
Proportional valve = P
Supply voltage 24 VDC = G24
Electrical connection
Without mating connector with connector according to DIN EN 175201-804 = K31
(separate order, see page 12)
Electronics interfaces
Command value 0...+10 V, actual value +0.5...+10 V = A1
Command value 0...+10 mA, actual value +0.5...+10 mA = C1
Sandwich plate shut-off valve
Without shut-off valve = no code
With shut-off valve:
Shut-off valve switched to de-energized actively closes 2WRCE with applied pilot pressure = WK15
Shut-off valve switched to de-energized actively opens 2WRCE with applied pilot pressure = WL15
Seal material
NBR seals = M
FKM seals =
V
Further details in the plain text
2 WRCE S 2X P
G24
K31 *
Ordering code: Type 2WRCE
Hydraulics Bosch Rexroth AG 3/24
RE 29137/08.13 .WRCE.../P
3/2 directional valve = 3
Electrically operated high-response
valve for block installation with integrated
electronics (OBE) = WRCE
Size 32 = 32
Size 40 = 40
Size 50 = 50
Control spool, zero overlap (+0.5...+1.5%) = V
Control spool, with 10…13% positive overlap = E
Rated flow in l/min at 5 bar valve pressure drop
Size32: 290l/minlinearonly...V290L...
250 l/min with fine control range only ...E250P...
= 290
= 250
Size 40: 460 l/min linear only ...V460L...
410 l/min with fine control range only ...E410P...
= 460
= 410
Size 50: 720 l/min linear only ...V720L...
620 l/min with fine control range only ...E620P...
= 720
= 620
Characteristic curve form
Linear = L
Linear with linear fine control range = P
Componentseries20to29 = 2X
(20to29:Unchangedinstallationandconnectiondimensions)
Pilot control valve (pilot)
Proportional valve = P
Supply voltage 24 VDC = G24
Electrical connection
Without mating connector with connector according to DIN EN 175201-804 = K31
(separate order, see page 12)
Electronics interfaces
Command value ±10 V, actual value ±10 V = A1
Command value ±10 mA, actual value ±10 mA = C1
Sandwich plate shut-off valve
Without shut-off valve = no code
With shut-off valve:
Shut-off valve switched to de-energized actively opens 3WRCE with applied pilot pressure from A to T
= WK15
Shut-off valve switched to de-energized actively opens 3WRCE with applied pilot pressure from P to A
= WL15
Voltage supply 24 VDC, mating connector, separate order, refer to page 12 (without circuitry)
Seal material
NBR seals = M
FKM seals =
V
Further details in the plain text
3 WRCE 2X P
G24
K31 *
Ordering code: Type 3WRCE – Not for new applications! (refer to page 7)
4/24 Bosch Rexroth AG Hydraulics
.WRCE.../P RE 29137/08.13
Symbols: Type 2WRCE
Simplified Detailed
2WRCE..-2X/P... 2WRCE..-2X/P...

2WRCE..-2X/P...WK15... 2WRCE..-2X/P...WK15...

2WRCE..-2X/P...WL15... 2WRCE..-2X/P...WL15...

Hydraulics Bosch Rexroth AG 5/24
RE 29137/08.13 .WRCE.../P
Symbols: Type 3WRCE – Not for new applications! (refer to page 7)
Simplified Detailed
3WRCE..V...-2X/P... 3WRCE..V...-2X/P...

3WRCE..V...-2X/P...WK15... 3WRCE..V...-2X/P...WK15...

3WRCE..V...-2X/P...WL15... 3WRCE..V...-2X/P...WL15...

3WRCE..E...-2X/P... 3WRCE..E...-2X/P...

6/24 Bosch Rexroth AG Hydraulics





.WRCE.../P RE 29137/08.13
Set-up, function and section: Type 2WRCE
Valves of type 2WRCE...-2X/P... are 2-stage high-response valves.
They control the quantity and direction of a flow and are
mainly used in control loops.
Set-up
They consist of the following assemblies:
The pilot control valve (1) as 1-stage proportional valve (pi-
lot), with two solenoids as electro-mechanical converters
and a piston that is connected to the integrated pilot elec-
tronics via electrical feedback (6.2).
The second stage (2) for flow control.
An inductive position transducer (3) the core (4) of which is
attached to the piston (5) of the second stage.
And integrated control electronics (6.1).
Function
The integrated electronics (OBE) compares command and actu-
al values and the solenoids of the pilot control valve are actuat-
ed with a proportional current according to the control deviation.
The pilot control valve takes a proportionally controlled po-
sition and controls the flow in and out of the control cham-
bers A (7) and B (8) that actuate the main spool (5) through
the closed valve control loop up to 0 control deviation.
This means that the stroke of the main spool is regulated pro-
portionally to the command value. It must be noted that the
flow also depends on the valve pressure drop.
Valve particularities
The flow can pass through the valve from A to B or from B to A.
The seat piston closes or opens at 5% of the command value.
At lower command values, the valve control loop attempts to
guide the piston and thus presses it onto the seat at full pilot
pressure and blocks the connection in a leak-free way.
The specified valve dynamics only apply to the control area
of the valve. At command value steps from the seat to lower
opening values, additional delay times occur.
The opening point of 5% (= 0.5 V or 0.5 mA) is set at the factory.
Due to the internal setting of the pilot control valve, the pi-
lot pressure is connected to control chamber B (8) in case of
a power failure, i.e. the main stage is closed.
The control electronics feature an offset setting to compen-
sate pilot trimming.
Due to differences in diameter in the seat range, the pistons
are statically not pressure-compensated. To compensate
the force differential, 6%/22% of the system pressure at pis-
ton S...L/S...R is required as pilot pressure. With reserves for
flow force and dynamics, this defines the recommended mini-
mum pilot pressure.
"X"
1)
Preferably, port B is to be connected to the actuator.
Hydraulics Bosch Rexroth AG






7/24
RE 29137/08.13 .WRCE.../P
Set-up, function and section: Type 3WRCE
1)
Valves of type 3WRCE...-2X/P... are 2-stage high-response valves.
They control the quantity and direction of a flow and are
mainly used in control loops.
Set-up
They consist of the following assemblies:
The pilot control valve (1) as 1-stage proportional valve (pi-
lot), with two solenoids as electro-mechanical converters
and a piston that is connected to the integrated pilot elec-
tronics via electrical feedback (6.2).
The second stage (2) for flow control.
An inductive position transducer (3) the core (4) of which is
attached to the piston (5) of the second stage.
And integrated control electronics (6.1).
Function
The integrated electronics (OBE) compares command and
actual values and the solenoids of the pilot control valve are
actuated with a proportional current according to the con-
trol deviation.
The pilot control valve takes a proportionally controlled po-
sition and controls the flow in and out of the control cham-
bers A (7) and B (8) that actuate the main spool (5) through
the closed valve control loop up to 0 control deviation.
This means that the stroke of the main spool is regulated pro-
portionally to the command value. It must be noted that the
flow also depends on the valve pressure drop.
Valve particularities
The opening point of 0% (V piston) is set at the factory.
Due to the internal setting of the pilot control valve, the pi-
lot pressure is connected to control chamber B (8) in case of
a power failure, i.e. the main stage is opened from A to T or
the connection P to A is closed.
The spring behind the main spool moves it into position
so that P to A is closed if no pressure is applied (e.g. pri-
or to installation, before the pressures are reapplied after
tool change).
The control electronics feature an offset setting to compen-
sate pilot trimming.
"X"
1)
Not for new applications!
2)
Please use the variant with swapped P and A.
Uponrequest!
8/24 Bosch Rexroth AG Hydraulics
.WRCE.../P RE 29137/08.13
Technical data: Type 2WRCE (For applications outside these values, please contact us!)
Q
Lmin
=0.0026•p
x
[bar]
L
min bar
Q
Lmax
=0.0095•p
x
[bar]
L
min bar
general
Sizes
Size
32 40 50
Weight
kg
12.5 19.9 26.8
Weight with shut-off valve ...../...WK or .../...WL...
kg
13.7 21.1 28
Size of the pilot control valve (pilot)
Size
6 6 6
Installation position; commissioning Any, preferably horizontal; according to data sheet 07700
Storage temperature range
°C
–20 to +80
Ambient temperature range
°C
–20 to +50
SinetestaccordingtoprEN60068-2-6:1995 5...2000 Hz / maximum of 10 g / 10 cycles
RandomtestaccordingtoIEC68-2-36:1973 20…2000 Hz / 10 g
RMS
/ 30 min
ShocktestaccordingtoEN60068-2-27:1993 15 g / 11 ms
hydraulic (measuredwithHLP32,ϑ
oil
= 40 °C ±5 °C)
Maximum operating pressures
– Main stage ports A, B
bar
420
– Pilot control valve port X
bar
315
– Pilot control valve port Y
bar
210
Minimum pilot pressure in % of system pressure
– For piston design S...L
%
15
– For piston design S...R
%
45
Rated flow Q
Vrated
+10% at ∆p = 5 bar
– Design ...S...L (linear)
l/min
650 1000 1600
Design ...S...R
(linear with progressive fine control range)
l/min
480
700
1100
Maximum flow – For piston ...S...L
l/min
1500 2200 3500
– For piston ...S...R
l/min
2000 3000 4500
Pilot flow at X and Y with stepped
input signal from 0 to 100% (315 bar)
l/min
37
45
60
Zero flow of the proportional preliminary step depen-
dent on the pressure in line X
l/min
Pilot oil volume
cm
3
4.52 8.48 17.3
Hydraulic fluid Seetableonpage9
Hydraulic fluid temperature range
°C
–20 to +80; preferably +40 to +50
Viscosity range
mm
2
/s
20 to 380; preferably 30 to 45
Maximum admissible degree of contamination of the hydraulic fluid,
cleanliness class according to ISO 4406 (c)
Class 20/18/15
1)
Hysteresis
%
≤0.2
Range of inversion
%
≤0.1
Response sensitivity
%
≤0.1
Closing time during use – Pilot control valve
ms
≤200
(pilot pressures
from 40 to 315 bar)
Sandwich plate shut-
off valve
ms
≤200
1)
The cleanliness classes stated for the components need to be maintained in hydraulic systems. Effective filtration prevents
faults and at the same time increases the life cycle of the components.
For the selection of the filters see www.boschrexroth.com/filter
Hydraulics Bosch Rexroth AG 9/24
RE 29137/08.13 .WRCE.../P




Technical data: Type 2WRCE (for applications outside these values, please contact us!
electric
Sizes Size 32 40 50
Voltage type Direct voltage
Type of signal Analog
Opening point calibration % ≤1
Zero shift upon change of:
– Hydraulic fluid temperature %/10 K ≤0.3 ≤0.3 ≤0.3
– Pilot pressure in X %/100 bar ≤0.7 ≤0.7 ≤0.7
– Return flow pressure in Y %/bar ≤0.3 ≤0.3 ≤0.3
ProtectionclassofthevalveaccordingtoEN60529 IP65 with mating connector mounted and locked
EMC compatibility TestedaccordingtoEN61000-6-2:2001/VDE0839
part6-2andEN61000-6-3:2001/VDE0839part6-3
Integrated electronics (OBE) type TV 13037
Block diagram, see page 11
Nominal command value range for 2WRC:
0 to +10 V (mA)
0 to 100%
In the command value range of 0 to 0.5 V, the actual value
remains constant at 0.5 V.
In case of a slow command value modification
from 0.5 V to +10 V, the actual value follows the command
value within ±0.15 V.
For command values over +10 V, the actual value follows up
to approx. +12 V.
At a command value step to +10 V, the actual value can tem-
porarily reach values of up to approx. +10.5 V.
Command value in V
Actual value in V
Hydraulic fluid Classification Suitable sealing materials Standards
Mineral oils and related hydrocarbons HL, HLP NBR, FKM DIN 51524
Flame-resistant – containing water
HFC (Fuchs HYDROTHERM 46 M,
PetroferUltraSafe620)
NBR ISO12922
Important information on hydraulic fluids!
For more information and data on the use of other hydrau-
licfluids,refertodatasheet90220orcontactus.
There may be limitations regarding the technical valve
data (temperature, pressure range, life cycle, maintenance
intervals, etc.)!
The flash point of the process and operating medium
used must be 40 K over the maximum solenoid sur-
face temperature.
Flame-resistant – containing water: Maximum pressure
differential per control edge is 175 bar. Pressure pre-
loading at the tank port > 20% of the pressure differential;
otherwise, increased cavitation.
Life cycle as compared to operation with mineral oil HL,
HLP 50% to 100%.
10/24 Bosch Rexroth AG Hydraulics
.WRCE.../P RE 29137/08.13
Technical data: Type 3WRCE
1)
(For applications outside these values, please consult us!)
general
Sizes
Size
32 40 50
Weight
kg
12.8 20.2 28
Weight with shut-off valve ...../...WK or .../...WL...
kg
14 21.4 29,2
Size of the pilot control valve (pilot)
Size
6 6 6
Installation position; commissioning Any, preferably horizontal; according to data sheet 07700
Storage temperature range
°C
–20 to +80
Ambient temperature range
°C
–20 to +50
SinetestaccordingtoprEN60068-2-6:1995 5...2000 Hz / maximum of 10 g / 10 cycles
RandomtestaccordingtoIEC68-2-36:1973 20…2000 Hz / 10 g
RMS
/ 30 min
ShocktestaccordingtoEN60068-2-27:1993 15 g / 11 ms
hydraulic (measuredwithHLP32,ϑ
oil
= 40 °C ± 5 °C)
Maximum operating pressures
– Main stage ports A, B, T
bar
315
– Pilot control valve port X
bar
315
– Pilot control valve port Y
bar
210
Rated flow Q
Vrated
+10% at ∆p = 5 bar
– Design ...V...L (linear)
l/min
290 460 720
Maximum flow
l/min
900 1400 2200
Pilot flow at X and Y with stepped input signal
from 0 to 100% (315 bar)
l/min
20
35
55
Maximum zero flow of the main stage at p
p
= 300 bar
l/min
4 6 8
Zero flow of the proportional preliminary step depen-
dent on the pressure in line X
l/min
Pilot oil volume
cm
3
±2.26 ±4.24 ±8.65
Hydraulic fluid Seepage9
Hydraulic fluid temperature range
°C
–20 to +80; preferably +40 to +50
Viscosity range
mm
2
/s
20 to 380; preferably 30 to 45
Maximum admissible degree of contamination of the hydraulic fluid,
cleanliness class according to ISO 4406 (c)
Class 20/18/15
2)
Hysteresis
%
≤0.2
Range of inversion
%
≤0.1
Response sensitivity
%
≤0.1
Closing time when using – Pilot control valve
ms
≤200
(pilot pressures
from 40 to 315 bar)
Sandwich plate shut-
off valve
ms
≤200
Q
Lmin
=0.0026•p
x
[bar]
L
min bar
Q
Lmin
=0.0095•p
x
[bar]
L
min bar
1)
Not for new applications!
2)
The cleanliness classes stated for the components need to be maintained in hydraulic systems. Effective filtration prevents
faults and at the same time increases the life cycle of the components.
For the selection of the filters see www.boschrexroth.com/filter
Hydraulics Bosch Rexroth AG










11/24
RE 29137/08.13 .WRCE.../P
Nominal command value range for 3WRCE:
0 to ±10 V (mA)
0 to ±100%
In case of a slow command value modification
from 0 V to +10 V, the actual value follows the command
value within ±0.15 V.
For command values over 10 V, the actual value follows up to
approx. ±13 V.
At a command value step to ±10 V, the actual value can
reach short-time values of up to approx. ±10.5 V.
Command value in V
Actual value in V
Block diagram
2 WRCE:
2)
Actual value +0.5 V … +10 V
or +0.5 mA … +10 mA
3 WRCE:
2)
Actual value ±10 V
or ±10 mA
Controller
Zero point
Pilot
2 WRCE:
1)
Command value 0 ... +10 V
or 0 … +10 mA
3 WRCE:
1)
Command value ±10 V
or ±10 mA
Pilot valve
Position transducer
Zero point
R316
Sensitivity
R318
Oscillator
Demodulator
Red
Blue
Brown
Black
electric
Sizes Size 32 40 50
Voltage type Direct voltage
Type of signal Analog
Opening point calibration % ≤1
Zero shift upon change of:
– Hydraulic fluid temperature %/10 K ≤0.3 ≤0.3 ≤0.3
– Pilot pressure in X %/100 bar ≤0.7 ≤0.7 ≤0.7
– Return flow pressure in Y %/bar ≤0.3 ≤0.3 ≤0.3
ProtectionclassofthevalveaccordingtoEN60529 IP65 with mating connector mounted and locked
EMC compatibility TestedaccordingtoEN61000-6-2:2001/VDE0839
part6-2andEN61000-6-3:2001/VDE0839part6-3
Supply voltage
24 V DC
0 V DC
Interface Integrated electronics (OBE) Valve
1A, fast
1)
Signal D positive against E effectuated at:
2)
Signal F positive against D:
2WRCE – opening 2WRCE – opening
3WRCE–openingfromP→A
3WRCE–openingfromP→A
1)
Not for new applications!
Technical data: Type 3WRC(E)
1)
(For applications outside these values, please consult us!)
Integrated electronics (OBE) type TV 13037
12/24 Bosch Rexroth AG Hydraulics





.WRCE.../P RE 29137/08.13
Electrical connection, mating connectors
Connector pin assignment
Pin Assignment of electronics interface A1 Assignment of electronics interface C1
2WRCE 3WRCE 2 WRCE 3WRCE
Supply voltage A 24 VDC nominal (18 ... 30 V; I
average
= 1 A, I
peak
= 3 A)
B 0 VDC
Measurement zero C Reference to pin F
Differential command value input
D 0 to +10 V 0 to ±10 V 0 to +10 mA 0 to ±10 mA
E Input resistance
>100kΩ
Input resistance
>100kΩ
Load
100Ω
Load
100Ω
Actual value reference
is contact C
1)
F +0.5 to +10 V
Max. 10 mA
0 to ±10 V
Max. 10 mA
+0.5 to +10 mA
Max.load1kΩ
0 to ±10 mA
Max.load1kΩ
Protective earth PE Connected to valve housing
Do not connect if the valve has already been grounded via the system
1)
Command and actual value have the same polarity. In case of failure of the fuse "1A fast", the actual value may temporarily
also be measured between F and B.
Notice: Do not use electrical signals provided via control electronics (e.g. actual value) for switching safety-relevant
machine functions (see also EN ISO 13849 "Safety of machinery – safety-related parts of control systems").
Mating connectors for shut-off valve according to DIN EN 175301-803 for connector "K4"
Mating connector
Mating connector according to DIN EN 175201-804
separate order under the material no. R900021267
(plastic version)
Mating connector
Mating connector according to DIN EN 175201-804
separate order under the material no. R9000223890
(metal version)
For more mating
connectors,
refer to RE 08006
Material no.
Valve
side Color without circuitry
with indicator light
12 … 240 V
with rectifier
12 … 240 V
with indicator light and Zener
diode suppression circuit
24 V
a Gray R901017010
a/b Black R901017022 R901017025 R901017026
Hydraulics Bosch Rexroth AG















































13/24
RE 29137/08.13 .WRCE.../P
Characteristic curves (measured with HLP32, ϑ
oil
= 40 °C ±5 °C)
Commandvaluein%→
Ratedflowinl/min→
Rated flow at 5 bar valve pressure differential A →B = B →A
2WRCE 50 S1600L
2WRCE 40 S1000L
2WRCE 32 S650L
Commandvaluein%→
Ratedflowinl/min→
Rated flow at 5 bar valve pressure differential A →B = B →A
2WRCE 50 S1100R
2WRCE 40 S700R
2WRCE 32 S480R
Commandvaluein%→
Ratedflowinl/min→
Rated flow at 5 bar valve pressure differential
3WRCE 50 V720L
3WRCE 40 V460L
3WRCE32V290L
(overlap +0.5...+1.5%)
Commandvaluein%→
Ratedflowinl/min→
Rated flow at 5 bar valve pressure differential with 10% overlap 3WRCE 50 E620P
3WRCE 40 E410P
3WRCE 32 E250P
Command value in %
Rated flow in l/min
14/24 Bosch Rexroth AG Hydraulics







.WRCE.../P RE 29137/08.13
Characteristic curves (measured with HLP32, ϑ
oil
= 40 °C ±5 °C)
U
E
/ U
EN
in %
Pressure p
A
/ p
p
in%→
Pressure signal function at 3WRCE...V... limit and average value characteristic curves
Hydraulics Bosch Rexroth AG




 









 






 



 

15/24
RE 29137/08.13 .WRCE.../P
Characteristic curves (measured with HLP32, ϑ
oil
= 40 °C ±5 °C)
Timeinms→
PositioninV→
Transition function
40 bar, 70 bar, 140 bar, 210 bar, 315 bar
2WRCE 32…
Timeinms→
PositioninV→
2WRCE 40…
Timeinms→
PositioninV→
2WRCE 50…
16/24 Bosch Rexroth AG Hydraulics







 
40 bar, 70 bar, 140 bar, 210 bar, 315 bar







 









   
.WRCE.../P RE 29137/08.13
Timeinms→
PositioninV→
3WRCE 32…
Timeinms→
PositioninV→
3WRCE 40…
Timeinms→
PositioninV→
3WRCE 50…
Characteristic curves (measured with HLP32, ϑ
oil
= 40 °C ±5 °C)
Transition function
Hydraulics Bosch Rexroth AG
















 

















  
















 

17/24
RE 29137/08.13 .WRCE.../P
Characteristic curves (measured with HLP32, ϑ
oil
= 40 °C ±5 °C)
FrequencyinHz→
AmplituderatioindB→
Frequency response at p
st
= 315 bar
Command value
50% ±5%
50% ±25%
50% ±45%
2WRCE 32…
FrequencyinHz→
AmplituderatioindB→
Command value
50% ±5%
50% ±25%
50% ±45%
2WRCE 40…
FrequencyinHz→
AmplituderatioindB→
Command value
50% ±5%
50% ±25%
50% ±45%
2WRCE 50…
Phaseanglein°→
Phaseanglein°→Phaseanglein°→
18/24 Bosch Rexroth AG Hydraulics















 








 







   
















 

.WRCE.../P RE 29137/08.13
Characteristic curves (measured with HLP32, ϑ
oil
= 40 °C ±5 °C)
FrequencyinHz→
AmplituderatioindB→
Frequency response at p
st
= 315 bar
Command value
±5%
±25%
±100%
3WRCE 32…
FrequencyinHz→
AmplituderatioindB→
Command value
±5%
±25%
±100%
3WRCE 40…
FrequencyinHz→
AmplituderatioindB→
Command value
±5%
±25%
±100%
3WRCE 50…
Phaseanglein°→Phaseanglein°→
Phaseanglein°→
Hydraulics Bosch Rexroth AG














   











 
 













  

 












 







































19/24
RE 29137/08.13 .WRCE.../P
Characteristic curves (measured with HLP32, ϑ
oil
= 40 °C ±5 °C)
Frequencyat–90°inHz→
Inletamplitude→
Dependency of the frequency f at –90° on the operating pressure p and the inlet amplitude
2WRCE 32…
Frequencyat–90°inHz→
Inletamplitude→
2WRCE 40…
Frequencyat–90°inHz→
Inletamplitude→
2WRCE 50…
Frequencyat–90°inHz→
Inletamplitude→
3WRCE 32…
Frequencyat–90°inHz→
Inletamplitude→
3WRCE 40…
Frequencyat–90°inHz→
Inletamplitude→
3WRCE 50…
p
st
= 40 bar p
st
= 140 bar p
st
= 315 bar
p
st
= 70 bar p
st
= 210 bar
20/24 Bosch Rexroth AG Hydraulics

















.WRCE.../P RE 29137/08.13
Dimensions: Types 2WRCE and 3WRCE
1)
, size 32 (dimensions in mm)
1 Pilot control valve (proportional valve size 6)
2 Sandwich plate shut-off valve
(only with versions "WK15" and "WL15")
3 Bushing
4 Mating connector according
to DIN EN 175201-804
(separate order, see page 12)
5 Mating connector according
to DIN EN 175301-803
(separate order, see page 12)
6 Space required for removing the mat-
ing connector
7 Cabling
8 Valve mounting screws, see page 24
9 Locking pin for fixing
10 Identical seal rings for ports X and Y
11 Name plate
3WRCE 32...
1)
(missing dimensions as 2WRCE 32...)
2WRCE 32
1)
Not for new applications!


Required surface quality of the
valve contact surface
Hydraulics Bosch Rexroth AG



















21/24
RE 29137/08.13 .WRCE.../P
Dimensions: Types 2WRCE and 3WRCE
1)
, size 40 (dimensions in mm)
1 Pilot control valve (proportional valve size 6)
2 Sandwich plate shut-off valve
(only with versions "WK15" and "WL15")
3 Bushing
4 Mating connector according
to DIN EN 175201-804
(separate order, see page 12)
5 Mating connector according
to DIN EN 175301-803
(separate order, see page 12)
6 Space required for removing the mat-
ing connector
7 Cabling
8 Valve mounting screws, see page 24
9 Locking pin for fixing
10 Identical seal rings for ports X and Y
11 Name plate
2WRCE 40
3WRCE 40...
1)
(missing dimensions as 2WRCE 40...)
Required surface quality of the
valve contact surface
1)
Not for new applications!
22/24 Bosch Rexroth AG Hydraulics


















.WRCE.../P RE 29137/08.13
Dimensions: Types 2WRCE and 3WRCE
1)
, size 50 (dimensions in mm)
1 Pilot control valve (proportional valve
size 6)
2 Sandwich plate shut-off valve
(only with versions WK15 and WL15)
3 Bushing
4 Mating connector according
to DIN EN 175201-804
(separate order, see page 12)
5 Mating connector according
to DIN EN 175301-803
(separate order, see page 12)
6 Space required for removing the mat-
ing connector
7 Cabling
8 Valve mounting screws, see page 24
9 Locking pin for fixing
10 Identical seal rings for ports X and Y
11 Name plate
3WRCE 50...
1)
(missing dimensions as 2WRCE 50...)
2WRCE 50
1)
Not for new applications!


Required surface quality of the
valve contact surface
Hydraulics Bosch Rexroth AG

































































23/24
RE 29137/08.13 .WRCE.../P
Installation dimensions according to DIN ISO 7368 (dimensions in mm)
Size 32 40 50
ØD1
H7
60 75 90
ØD2
H7
58 73 87
ØD3
H7
55 55 68
ØD4 32 40 50
ØD5 24 30 35
ØD6
H7
45 55 68
ØD7 32 40 50
D8 M16 M20 M20
max. ØD9 8 10 10
ØD10 6 6 8
H1 70 87 100
H2 85 105 122
H3 52 64 72
H4 30 30 35
H5 13 15 17
H7 43.5 54 87
H8 85 105 143
H9 100 125 165
H10 30 36 66
H11 70.5 87 122
H12 18 21 48
H13 15 18 18
H16 2.5 3 4
H17 2.5 3 3
H18 35 45 45
L1 105 125 140
L2 70 85 100
L3 35 42.5 50
L4 41 50 58
L5 17 23 30
Size 32 … 50
Installation bore type 2WRCE
according to DIN ISO 7368
Installation bore type 3WRCE
1 Depth of fit, minimum dimension
2 The ports P, T and B can be positioned around the central
axis of port A. Sufficient distance from the mounting bores
and control bores is to be observed.
3 Locating hole for locking pin
Tolerances according to: General tolerances ISO 2768-mK
24/24 Bosch Rexroth AG Hydraulics
.WRCE.../P RE 29137/08.13
Bosch Rexroth AG
Hydraulics
Zum Eisengießer 1
97816 Lohr am Main, Germany
Phone +49 (0) 93 52 / 18-0
documentation@boschrexroth.de
www.boschrexroth.de
© This document, as well as the data, specifications and other informa-
tion set forth in it, are the exclusive property of Bosch Rexroth AG. It may
not be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No state-
ments concerning a certain condition or suitability for a certain application
can be derived from our information. The information given does not
release the user from the obligation of own judgment and verification. It
must be remembered that our products are subject to a natural process
of wear and aging.
Hexagon socket head cap screws
Size 32 4xISO4762-M16x100-10.9
Tightening torque M
A
= 280 Nm ±10%
Size 40 4xISO4762-M20x180-10.9
Tightening torque M
A
= 560 Nm ±10%
Size 50 4xISO4762-M20x190-10.9
Tightening torque M
A
= 560 Nm ±10%
Notice: The tightening torque of the hexagon socket head cap
screws refers to maximum operating pressure!
Accessories (not included in the scope of delivery)
Project planning / maintenance instructions / additional information
General operating instructions: Hydraulic valves for industrial applications, see data sheet 07600-B
– Assembly,commissioningandmaintenanceofhydraulicsystems,seedatasheet07900
Installation, commissioning and maintenance of servo valves and high-response valves, see data sheet 07700
Assembly, commissioning and maintenance of proportional valves, see data sheet 07800