6/18 4WREE | Proportional directional valve
Bosch Rexroth AG, RE29105, edition: 2018-12
static /dynamic
Hysteresis % < 0.1
Range of inversion % < 0.05
Response sensitivity % < 0.05
Zero shift upon change of hydraulic fluid temperature
and operating pressure
%/10 K ≤ 0.15
%/100 bar ≤ 0.1
Technical data
(for applications outside these values, please consult us!)
electrical, integrated electronics (OBE)
Voltage type Direct voltage
Supply voltage ▶ Nominal voltage VDC 24
▶ Lower limit value V 19
▶ Upper limit value V 36
Maximum admissible residual ripple Vpp 2.5
Current consumption of
the amplifier
▶ I
max
A < 2
▶ Impulse current A 3
Solenoid coil resistance ▶ Cold value at 20 °C
Ω
2.65
▶ Maximum hot value
Ω
4.05
Duty cycle % 100
Maximum coil temperature
2)
°C 150
Protection class of the valve according to EN60529 IP65 (with mating connector mounted and locked)
Electro-magnetic compatibility (EMC) ▶ Interference resistance prEN50082-2
▶ Interference emission EN50081-1
2)
Due to the arising surface temperatures of the solenoid coils, the
standards ISO 13732-1 and ISO4413 are to be observed.
Hydraulic fluid Classification Suitable sealing materials Standards Data sheet
Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN51524 90220
Bio-degradable ▶ Insoluble in water HETG FKM
ISO15380
90221HEES FKM
▶ Soluble in water HEPG FKM ISO15380
Flame-resistant ▶ Water-free HFDU (glycol base) FKM
ISO 12922 90222HFDU (ester base) FKM
HFDR FKM
▶ Containing water HFC (Fuchs: Hydrotherm 46M,
Renosafe 500;
Petrofer: Ultra Safe 620;
Houghton: Safe620;
Union: Carbide HP5046)
NBR
ISO 12922 90223
Important information on hydraulic fluids:
▶ For further information and data on the use of other hydraulic
fluids, please refer to the data sheets above or contact us.
▶ There may be limitations regarding the technical valve data
(temperature, pressure range, life cycle, maintenance intervals,
etc.).
▶ The ignition temperature of the hydraulic fluid used must be 50K
higher than the maximum surface temperature.
▶ Bio-degradable and flame-resistant – containing water: If this
hydraulic fluid is used, small amounts of dissolved zinc may get
into the hydraulic system.
▶ Flame-resistant – containing water:
– Due to increased cavitation tendency with HFC hydraulic fluids,
the life cycle of the component may be reduced by up to 30%
as compared to the use with mineral oil HLP. In order to reduce
the cavitation effect, it is recommended - if possible specific to
the installation - to back up the return flow pressure in portsT
to approx. 20% of the pressure differential at the component.
– Dependent on the hydraulic fluid used, the maximum ambient
and hydraulic fluid temperature must not exceed 50°C. In
order to reduce the heat input into the component, the
command value profile is to be adjusted for proportional and
high-response valves.