Hydraulics Bosch Rexroth AGRE 29089/01.09 4WRLE 10...35
5/16
Technical data
General
Construction Spool type valve, pilot operated
Actuation Servo solenoid directional control valve NG6, with position controller
for pilot valve and main stage
Type of mounting Subplate, mounting hole configuration NG10...35 to ISO 4401-...
Installation position Optional
Ambient temperature range °C –20...+50
Weight kg NG10 8.7 NG16 10.6 NG25 18.4 NG27 18.4 NG35 81
Vibration resistance, test condition Max. 25 g, shaken in 3 dimensions (24 h)
Static/Dynamic
Overlap in mid position
ª18...22 % of spool stroke, electrically compensated for U
D–E
±0.5 V
Spool stroke, main stage ± mm 4 7 10 10 12,5
Control oil volume
of main stage 100 % cm
3
1.1 4.3 11.3 11.3 41.5
Control oil requirement 0...100 %,
(at X = 100 bar) l/min 2.2 4.7 11.7 11.7 15.6
Hysteresis % <0.1, scarcely measurable
Manufacturing tolerance % < ± 5 (Q
max
)
Response time for 0...100 %,
(at X = 100 bar) ms <40 <80 <80 <80 <130
Response time for 0...100 %,
(at X = 10 bar) ms <150 <250 <250 <250 <500
Switch-off behavior After electrical switch-off (pilot valve in fail-safe)
Main stage moves to spring-centered overlapped mid position
Thermal drift <1 % at ∆T = 40 °C
Calibration At the factory ±1 %, see flow curve
Electromagnetic compatibility EN 61000-6-2: 2002-08
EN 61000-6-3: 2002-08
1)
The purity classes stated for the components must be complied with in hydraulic systems.
Effective filtration prevents problems and also extends the service life of components.
For a selection of filters, see Technical Data Sheets RE 50070, RE 50076 and RE 50081.
2)
Flow rate at a different ∆p Q
x
= Q
nom
·
∆p
x
5
!
w
Hydraulic (measured with HLP 46,
oil
= 40 °C ±5 °C)
Pressure fluid Hydraulic oil to DIN 51524...535, other fluids after prior consultation
Viscosity range recommended mm
2
/s 20...100
max. permitted mm
2
/s 10...800
Pressure fluid temperature range °C –20...+70
Maximum permissible degree
of contamination of pressure fluid
Purity class to ISO 4406 (c) Class 18/16/13
1)
Flow direction See symbol
Nominal flow at
∆p = 5 bar per notch
2)
l/min
NG10 NG16 NG25 NG27 NG35
50, 80 180 350 430 1100
Max. Ports P, A, B
working
(external control oil inlet) bar 350 350 350 280 350
pressure
Ports P, A, B, X bar 280
Ports T, Y bar 250
Min. control oil pressure
in “pilot stage” bar 8
Q
max
l/min 170 450 900 1000 3500
Q
N
pilot valve (inlet)
∆p = 35 bar l/min 2 4 12 12 40
Leakage of pilot valve
at X = 100 bar cm
3
/min <150 <180 <350 <500 <1100
Leakage of main stage
control spool symbols “E”