Pressure reducing valve | DR 6 DP 5/8
RE 26564, edition: 2019-01, Bosch Rexroth AG
general
Weight kg ca. 1.2
Installation position any
Ambient temperature range °C –30 … +80 (NBR seals)
–20 … +80 (FKM seals)
MTTF
D
values according to ENISO13849 Years 150 ... 1200 (for more information see datasheet08012)
hydraulic
Maximum operating pressure ▶ Port P bar 315
Maximum secondary pressure ▶ Port A bar 25; 75; 150; 210; 315
Maximum counter pressure ▶ Port T(Y) bar 160
Maximum flow l/min 60
Hydraulic fluid see table below
Hydraulic fluid temperature range °C –30 … +80 (NBR seals)
–20 … +80 (FKM seals)
Viscosity range mm
2
/s 10 … 800
Maximum admissible degree of contamination of the
hydraulic fluid, cleanliness class according to ISO4406 (c)
class 20/18/15
1)
Technical data
(For applications outside the stated values, please ask us!)
1)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents
faults and simultaneously increases the life cycle of the
components.
For the selection of filters, see www.boschrexroth.com/filter.
Hydraulic fluid Classification Suitable sealing materials Standards Datasheet
Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN51524 90220
Bio-degradable ▶ Insoluble in water HETG FKM
ISO15380
90221HEES FKM
▶ Soluble in water HEPG FKM ISO15380
Flame-resistant ▶ Water-free HFDU (glycol base) FKM
ISO12922 90222HFDU (ester base) FKM
HFDR FKM
▶ Containing water HFC (Fuchs: Hydrotherm 46M,
Fuchs Renosafe 500;
Petrofer: Ultra Safe 620;
Houghton: Safe 620;
Union: Carbide HP5046)
NBR
ISO12922 90223
Important information on hydraulic fluids:
▶ For further information and data on the use of other hydraulic
fluids, please refer to the data sheets above or contact us.
▶ There may be limitations regarding the technical valve data
(temperature, pressure range, life cycle, maintenance
intervals,etc.).
▶ The ignition temperature of the hydraulic fluid used must be
50Khigher than the maximum surface temperature.
▶ Bio-degradable and flame-resistant – containing water: If
components with galvanic zinc coating (e.g. version "J3" or "J5")
or parts containing zinc are used, small amounts of dissolved zinc
may get into the hydraulic system and cause accelerated aging of
the hydraulic fluid. Zinc soap may form as achemical reaction
product, which may clog filters, nozzles and solenoid
valves-particularly in connection with local heat input.
▶ Flame-resistant – containing water:
Due to increased cavitation tendency with HFC hydraulic fluids,
the life cycle of the component may be reduced by up to 30% as
compared to the use with mineral oil HLP. In order to reduce the
cavitation effect, it is recommended - if possible specific to the
installation - to back up the return flow pressure in ports T to
approx.20% of the pressure differential at the component.