Directional spool valve | WE 5/10
RE 23164, edition: 2013-01, Bosch Rexroth AG
hydraulic
Maximum operating pressure – Port A, B, P bar 315
– Port T bar 160 With symbols A and B, port T must be used as leakage port if
the operating pressure exceeds the permissible tank pressure.
Maximum flow l/min 60
Hydraulic fluid See table below
Hydraulic fluid temperature range °C –30 … +80
Viscosity range mm
2
/s 2.8 … 500
Maximum permitted degree of contamination of the hydraulic fluid-
cleanliness class according to ISO 4406 (c)
Class 20/18/15
1)
Technical data
(For applications outside these parameters, please consult us!)
1)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents faults
and at the same time increases the life cycle of the components.
For the selection of the filters see www.boschrexroth.com/filter.
Notice!
▶ Only actuate the manual override using a rounded
tool(Ø3
+1
mm) or special tool (separate order, mate-
rialno.R900024943)!
▶ Actuation of the manual override only up to a tank pressure of
approx. 50bar.
▶ When the manual override is blocked, the operation of the
solenoid must be prevented!
▶ The simultaneous operation of the solenoids must be prevented!
general
Weight – Valve with 1 solenoid kg Approx. 1.25
– Valve with 2 solenoids kg Approx. 1.6
Installation position Any
Ambient temperature range °C –30 … +50
Hydraulic fluid Classification Suitable sealing materials Standards
Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN 51524
Bio-degradable
– insoluble in water
HETG NBR, FKM
VDMA 24568
HEES FKM
– soluble in water
HEPG FKM VDMA 24568
Flame-resistant
– water-free
HFDU, HFDR FKM ISO 12922
– containing water
HFC (Fuchs Hydrotherm 46M,
Petrofer Ultra Safe 620)
NBR ISO 12922
Important information on hydraulic fluids!
▶ For more information and data on the use of other hydraulic fluids
refer to data sheet 90220 or contact us!
▶ There may be limitations regarding the technical valve data (tem-
perature, pressure range, life cycle, maintenance intervals, etc.)!
▶ The flash point of the hydraulic fluid used must be 40 K higher
than the maximum solenoid surface temperature.
▶ Flame-resistant – containing water:
– Maximum pressure differential per control edge 50bar
– Pressure pre-loading at the tank port >20% of the pressure
differential, otherwise increased cavitation
– Life cycle as compared to operation with mineral
oilHL,HLP50to 100%
▶ Bio-degradable: When using bio-degradable hydraulic fluids that
are simultaneously zinc-solving, zinc may accumulate in the fluid
(per pole tube 700mg zinc).