6/12 Z2S | Check valve
BoschRexrothAG, RE21548, edition: 2020-10
Technical data
(For applications outside these values, please consult us!)
Hydraulic
Maximum operating pressure
bar 350
Cracking pressure in free direction
seecharacteristic curves page7
Maximum flow
l/min 80
Direction of flow
seesymbols page3
Hydraulic fluid
seetable below
Hydraulic fluid temperature range
(at the valve working ports)
°C –30 ... +80 (NBR seals)
–20 … +80 (FKM seals)
Viscosity range
mm
2
/s 2,8 … 500
Maximum admissible degree of contamination of the
hydraulic fluid, cleanliness class according to ISO4406 (c)
Class20/18/15
1)
Area ratio ▶ Without pre-opening A
1
/A
2
~ 1/3.5 (seesectional drawing page4)
▶ With pre-opening A
3
/A
2
~ 1/12.5 (seesectional drawing page5)
▶ Version "SO60" A
1
/A
4
~ 1/7 (seesectional drawing page5)
General
Weight kg approx.0.8
Installation position any
Ambient temperature range °C –30 ... +80 (NBR seals)
–20 … +80 (FKM seals)
Storage temperature range seeoperating instructions 07600-B
MTTF
D
values according to ENISO13849 years 150 ... 1200 (for more information seedata sheet08012)
1)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents
faults and simultaneously increases the life cycle of the
components.
Hydraulic fluid Classification Suitable
sealing materials
Standards Datasheet
Mineral oils HL, HLP, HLPD, HVLP, HVLPD NBR, FKM DIN51524 90220
Bio-degradable ▶ Insoluble in water HETG FKM
ISO15380
90221HEES FKM
▶ Soluble in water HEPG FKM ISO15380
Flame-resistant ▶ Water-free HFDU (glycol base) FKM
ISO12922 90222HFDU (ester base) FKM
HFDR FKM
▶ Containing water HFC(Fuchs: Hydrotherm46M,
Renosafe500;
Petrofer: UltraSafe620; Hough-
ton: Safe620;
Union: CarbideHP5046)
NBR
ISO12922 90223
Important information on hydraulic uids:
▶ For further information and data on the use of other hydraulic
fluids, please refer to the data sheets above or contact us.
▶ There may be limitations regarding the technical valve data
(temperature, pressure range, life cycle, maintenance intervals,
etc.).
▶ The ignition temperature of the hydraulic fluid used must be 50K
higher than the maximum surface temperature.
▶ Bio-degradable and flame-resistant – containing water:
If components with galvanic zinc coating (e.g.version"J3" or "J5")
or parts containing zinc are used, small amounts of dissolved zinc
may get into the hydraulic system and cause accelerated aging of
the hydraulic fluid. Zinc soap may form as achemical reaction
product, which may clog filters, nozzles and solenoid valves –
particularly in connection with local heat input.
▶ Flame-resistant – containing water:
Due to the increased cavitation tendency with HFChydraulic
fluids, the life cycle of the component may be reduced by up to
30% as compared to the use with mineral oil HLP. In order to
reduce the cavitation effect, it is recommended - if possible
specific to the installation - to back up the return flow pressure
in portsT to approx.20% of the pressure differential at the
component.
For the selection of filters, seewww.boschrexroth.com/filter.