RE 18323-69/03.2020, Bosch Rexroth Oil Control S.p.A.
Proportional valves poppet type
not compensated fl ow regulator
Common cavity, Size 12
RE 18323-69
Edition: 03.2020
Replaces: 01.2016VEPN-12A OD.95.06.89.72.00
Technical data
General
Weight 0.29kg (0.64lbs)
Installation orientation Optional
Ambient temperature range -30 to 90°C (-22 to 194°F)
Salt spray test to
DIN EN ISO 9227:2017-07
500h
Hydraulic
Max. operating pressure 210bar (3000psi)
Flow range 5 - 60 l/min. (1 - 16 gpm)
Max. internal leakage 10 cm
3
/min. (0.6 cu.in/min.)
Fluid temperature range -20 to 80°C (-4 to 176°F)
Fluids: Mineral-based or synthetics with lubricating properties at
viscosities of 15 to 380 mm
2
/s (cSt)
Installation torque 51 - 55Nm (38 - 41ft-lbs)
Recommended degree of fl uid
contamination
Nominal value max. 10μm
(NAS 8) ISO 4406 19/17/14
Cavity CA-12A-2N see 18325-70
Lines bodies and standard assemblies Please refer to section
“Hydaulic integrated circuit”
or consult factory
Seal kit code
material no.
RG12A2010520100
R901111377
Seal kit coil code
material no.
RG16A1PMVQ0010
R934003962
Other technical data See data sheet 18350-50
Electrical
Type of voltage 12 DC voltage
Coil type R7
Supply voltage 12 DC
Nominal voltage ± 10%
Power consumption 18W
Duty cycle coil 100
Type of protection See data sheet 18325-90
Note: Coils must be ordered separately
▼ Version 06