RE 18307-52/03.2016, Bosch Rexroth Oil Control S.p.A.
Characteristic curve
Description
When pressure at V2 rises above the spring bias pressure,
the check seat is pushed away from the piston and flow is
allowed from V2 to C2. When load pressure at C2 rises
above the pressure setting, the direct-acting, differential
area, relief function is activated and flow is relieved from
C2 to V2. With pilot pressure at V1–C1 , the pressure
setting is reduced in proportion to the stated ratio of the
valve, until opening and allowing flow from C2 to V2. The
spring chamber is vented to atmosphere allowing operation
of all functions independent of back-pressure at V2.
Note: port identified with M are not protected with
calibrated orifice but in direct connection with pressure
channels.
Single counterbalance,
vented
RE 18307-52
Edition: 03.2016
Replaces: 03.2014
Flow Q
Pressure Δp
A-VBSO-SE-CCAP-33-PL 08.45.86 - X - Y - Z
Technical data
Max. operating pressure 410 bar (5945 psi)
Max. flow 150 l/min. (40 gpm)
Weight see “Dimensions”
Manifold material Zinc plated steel
Fluid Mineral oil (HL, HLP) according
DIN 51524
Fluid temperature range -30 °C to 100 (-22 to 212 °F)
Viscosity range 5 to 800 mm
2
/s (cSt)
Recommended degree of fluid
contamination
Class 19/17/14 according to
ISO 4406
MTTFd 150 years see 18350-51
Other technical data see data sheet 18350-50
Relief setting: at least 1.3 times the load induced pressure.
The pilot line includes adjustable hydraulic damping, for fine tuning
of stability and response.
Note: for applications outside these parameters, please consult us.