RE 18307-34/03.2016, Bosch Rexroth Oil Control S.p.A.
Description
When pressure at V2 rises above the spring bias pressure,
the check seat is pushed away from the piston and flow is
allowed from V2 to C2. When load pressure at C2 rises
above the pressure setting, the direct operated, differential
area, relief function is activated and flow is relieved from
C2 to V2. With pilot pressure at Pil, the pressure setting is
reduced in proportion to the stated ratio of the valve, until
opening and allowing flow from C2 to V2. The spring
chamber is drained to V2, and any back-pressure at V2 is
additive to the pressure setting in all functions.
Single counterbalance
RE 18307-34
Edition: 03.2016
Replaces: 04.2010A-VBSO-SE-78 08.35.20 - X - Y - Z
Technical data
Max. operating pressure 350 bar (5000 psi)
Max. flow 40 l/min. (11 gpm)
Weight 0.76 kg (1.68 lbs)
Manifold material Zinc plated steel
Fluid Mineral oil (HL, HLP) according
DIN 51524
Fluid temperature range -30 °C to 100 (-22 to 212 °F)
Viscosity range 5 to 800 mm
2
/s (cSt)
Recommended degree of fluid
contamination
Class 19/17/14 according to
ISO 4406
Other technical data see data sheet 18350-50
Relief setting: at least 1.3 times the load induced pressure.
Note: for applications outside these parameters, please consult us.
Characteristic curve
Flow Q
Pressure Δp