Bosch Rexroth AG, RE 18301-12/02.2016
2 D8_5… (EDD-XZ) | 4/3 and 4/2 on-off directional valve elements
Ordering details
Ordering details
01 02 03 04 05 06 07 08 09 10 11
D8 5 0
Family
01 Directional Valve elements EDD
D
Type
02 Size 8
8
Confi guration
03 Standard
0
With channels for Load Sens.
4
Coil type
04 C48
5
Spool variants
1)
05 4/3 operated on both sides a and b
_ 2 _ _
4/2 operated on side a only
_ 3 _ _
4/2 operated on side b only
_ 4 _ _
Voltage supply 31 07 03 01 00
06 Without coil
–––––00
12V DC
●●●●
–OB
13V DC
–
●
–
●
–AD
24V DC
●●●●
–OC
27V DC
–
●
–
●
–AC
48V DC
–––
●
–OD
24V AC (21.5 DC)
–––
●
–OV
110V AC (98 DC)
–––
●
–OW
230V AC (207 DC)
–––
●
–OZ
Electric connections
07 Without coils
00
With coils, without mating connector DIN EN 175301-803
01
4)
With coils, with bi-directional diode, without mating
connector vertical Amp-Junior
03
With coils, with bi-directional diode, without mating
connector DT04-2P
07
With coils and bipolar sheathed lead 350mm (13,8 in)
long
31
Ports
08 G 1/2 DIN 3852
2
SAE 10
D
Flangeable (A-B-T)
M
Secondary valve on A port
2)
09 Without secondary valve
0
Anti-cavitation function valve VUM
1
5)
Relief direct acting valve with anti-cavitation function
VMA
3)
(for setting see table below)
_
Secondary valve on B port
2)
10 Without secondary valve
0
Anti-cavitation function valve VUM
1
5)
Relief direct acting valve with anti-cavitation function
VMA
3)
(for setting see table below)
_
Options
11 No options
No
code
Push-button type manual override
0P
Screw type manual override
0F
●
= Available
–
= Not available
Symbols
= 0 = 4
A
A
A
A
A
A
A
B
B
B
B
B
B
B
P
P
P
P
P
P
P
T
T
T
T
TT
T
T
T
LS
Secondary valves possible confi gurations
Flangeable version =M
1) The required hydraulic symbol and spool variant can be
chosen by consulting page 2.
2) The use of the secondary valve in one ports implies the use of
secondary valve in both ports.
3) The relief direct acting valve have a maximum fl ow capacity of
30 l/min (7.93 gpm).
For the characteristic curves see data sheet RE18329-11.
4) For connectors ordering code see data sheet RE 18325-90.
5) For the Characteristic curves see data sheet RE18329-51.
ABCDEFGHI JKL
20
bar
30
bar
40
bar
50
bar
60
bar
70
bar
80
bar
90
bar
100
bar
110
bar
120
bar
130
bar
290
psi
435
psi
580
psi
725
psi
870
psi
1015
psi
1160
psi
1305
psi
1450
psi
1595
psi
1740
psi
1885
psi
MNOPQRS T UV WX
140
bar
150
bar
160
bar
170
bar
180
bar
190
bar
200
bar
210
bar
220
bar
230
bar
240
bar
250
bar
2030
psi
2175
psi
2320
psi
2465
psi
2611
psi
2756
psi
2901
psi
3046
psi
3191
psi
3336
psi
3481
psi
3626
psi