Bosch Rexroth AG, RE 18301-35/11.2025
2 EDG-OBE | 4/3 Proportional directional valve elements
Ordering details
Ordering details
Family
00 Directional Valve elements EDG Size 6
EDG
Type and configuration
01 Electro - Piloted with On Board Electronics
OBE
Ports & Connections
02 G 1/2 DIN 3852
G12
3/4-16 UNF 2-B (SAE8)
S08
Local compensator bias spring
03 8 bar (116 psi)
2
11 bar (160 psi)
4
Flange configuration
04 With P-TA-TB-LS-YA-YB-X-Y lines
2
With P-TA-TB-LS-YA-YB-X-Y lines and LS return line
3
Hydraulic connections in neutral
05 P, A, B closed and LS to T
B
P closed and A, B, LS to T
E
Spool variants
06 4/3 operated both sides A and B
2
Flow rates over valve connection (according to table 1)
07 Flow rate P>A
_
08 Flow rate P>B
_
09 Nominal flow rate (A>T)
_
4)
10 Nominal flow rate (B>T)
_
4)
CAN-Bus protocol
11 SAE J1939 (default)
J
5)
CAN Open
C
CAN-Bus baud rate
12 250 kbit/s (default)
2
5)
500 kbit/s
5
CAN-Bus node ID
13 00 (default)…15
_ _
5)
Secondary valve types
14 Without secondary valve
00
Double or single full relief valve with Anticavitation
(VMA) or anticavitation only (VUM) or plug
M0
2)
Double or single LS relief valve (VMGLS) or plug
0M
3)
Combination of M0 and 0M options together
MM
Secondary valve config. setting:
Full Relief or Anticavitation selection (according to table 2)
15 A>TA setting @5lpm
_
1)
16 B>TB setting @5lpm
_
1)
Secondary valve config. setting: LS Relief (VMGLS)
(according to table 3)
17 LSA>T setting range @1.5lpm
_
1)
18 LSB>T setting range @1.5lpm
_
1)
Ovveride option & Emergency Lewer
19 Without override
00
Lever type manual ovveride on A side - Horizontal
HA
Lever type manual ovveride on A side - Vertical
VA
Prepared for lever type manual override on A side
XA
6)
Lever type manual ovveride on A side - Horizontal
180° rotated
H1
Lever type manual ovveride on A side - Vertical
180° rotated
V1
Prepared for lever type manual override on A side -
180° rotated
X1
6)
1) "0" option is the only one available for "Without secondary valves"
selection.
2) For fixed setting relief valve data sheet see Data Sheet RE 18329-11.
For anticavitation valve data sheet see Data Sheet RE 18329-51.
3) See Table 3.
4) Asymmetrical spools available on request.
5) If not specified the default CAN-Bus configuration is CAN-Bus
protocol=SAE J1939 – baud rate=250 kbit/s – node ID=0.
Instructions to set or change the CAN-Bus node ID, the CAN-Bus
protocol and the CAN-Bus baud rate are available into the user
manual RE18301-34.
6) Selecting option “Prepared for lever type override”, the lever
K-2316 (R930083885) is included as spare item.
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
EDH - OBE - _ _ _ - _ _ - _ 2 _ _ _ _ - _ _ _ _ - _ _ - _ _ _ _ - _ _