RE 18301-35/11.2025, Bosch Rexroth AG
4/3 Proportional directional valve elements
EDG-OBE
RE 18301-35
Edition: 11.2025
Replaces: 07.12
4/3 Proportional directional valve elements
with LS - On Board Electronics
RE 18301-35
Edition: 11.2025
Replaces: 05.2025
General specifications
The inlet section can be configured for either a fixed
displacement pump or load-sense variable displacement
pump. When simultaneous machine functions are actuated,
the pre-compensators will automatically adjust to the
highest load pressure via a shuttle arrangement, making the
system circuit independent of variations in loads and pump
pressures. Thanks to modularity concept, it's possible to
combine stacks of flexible sections across the entire EDG
family. The new On Board Electronics (OBE) module
ensures the maximum efficiency in all working conditions,
thanks to a control loop that allows an integration and
communication between sensors and hydraulic
components.
Main Field of Application
Truck mounted applications
Forestry machinery
Forklifts and Telehandler
Municipal vehicles
Cranes
Construction machines
Mobile elevating working platforms
Heavy duty vehicles
Agricultural machines
Contents
Ordering details 2
Hydraulic layouts 4
Functional description 5
Technical data 6
Characteristic curves 7
External dimensions and fittings:
- Standard version 8
- Emergency lever option 9
Electric connections 10
EDG-OBE
Size 6
Maximum operating pressure:
- 350 bar (5000 psi) on pump side
- 350 bar (5000 psi) on consumer side
Maximum flow at 11 bar (160 psi) bias spring:
60 l/min (15.8 gpm)
Ports connections G 1/2 - SAE8
Note
The CAN-Bus (OBE) manual is available here: RE 18301-34
Bosch Rexroth AG, RE 18301-35/11.2025
2 EDG-OBE | 4/3 Proportional directional valve elements
Ordering details
Ordering details
Family
00 Directional Valve elements EDG Size 6
EDG
Type and configuration
01 Electro - Piloted with On Board Electronics
OBE
Ports & Connections
02 G 1/2 DIN 3852
G12
3/4-16 UNF 2-B (SAE8)
S08
Local compensator bias spring
03 8 bar (116 psi)
2
11 bar (160 psi)
4
Flange configuration
04 With P-TA-TB-LS-YA-YB-X-Y lines
2
With P-TA-TB-LS-YA-YB-X-Y lines and LS return line
3
Hydraulic connections in neutral
05 P, A, B closed and LS to T
B
P closed and A, B, LS to T
E
Spool variants
06 4/3 operated both sides A and B
2
Flow rates over valve connection (according to table 1)
07 Flow rate P>A
_
08 Flow rate P>B
_
09 Nominal flow rate (A>T)
_
4)
10 Nominal flow rate (B>T)
_
4)
CAN-Bus protocol
11 SAE J1939 (default)
J
5)
CAN Open
C
CAN-Bus baud rate
12 250 kbit/s (default)
2
5)
500 kbit/s
5
CAN-Bus node ID
13 00 (default)…15
_ _
5)
Secondary valve types
14 Without secondary valve
00
Double or single full relief valve with Anticavitation
(VMA) or anticavitation only (VUM) or plug
M0
2)
Double or single LS relief valve (VMGLS) or plug
0M
3)
Combination of M0 and 0M options together
MM
Secondary valve config. setting:
Full Relief or Anticavitation selection (according to table 2)
15 A>TA setting @5lpm
_
1)
16 B>TB setting @5lpm
_
1)
Secondary valve config. setting: LS Relief (VMGLS)
(according to table 3)
17 LSA>T setting range @1.5lpm
_
1)
18 LSB>T setting range @1.5lpm
_
1)
Ovveride option & Emergency Lewer
19 Without override
00
Lever type manual ovveride on A side - Horizontal
HA
Lever type manual ovveride on A side - Vertical
VA
Prepared for lever type manual override on A side
XA
6)
Lever type manual ovveride on A side - Horizontal
180° rotated
H1
Lever type manual ovveride on A side - Vertical
180° rotated
V1
Prepared for lever type manual override on A side -
180° rotated
X1
6)
1) "0" option is the only one available for "Without secondary valves"
selection.
2) For fixed setting relief valve data sheet see Data Sheet RE 18329-11.
For anticavitation valve data sheet see Data Sheet RE 18329-51.
3) See Table 3.
4) Asymmetrical spools available on request.
5) If not specified the default CAN-Bus configuration is CAN-Bus
protocol=SAE J1939 – baud rate=250 kbit/s – node ID=0.
Instructions to set or change the CAN-Bus node ID, the CAN-Bus
protocol and the CAN-Bus baud rate are available into the user
manual RE18301-34.
6) Selecting option “Prepared for lever type override”, the lever
K-2316 (R930083885) is included as spare item.
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19
EDH - OBE - _ _ _ - _ _ - _ 2 _ _ _ _ - _ _ _ _ - _ _ - _ _ _ _ - _ _
RE 18301-35/11.2025, Bosch Rexroth AG
4/3 Proportional directional valve elements | EDG-OBE
Ordering details
3
Ordering details
A B C D E F G H I J K
50
bar
60
bar
70
bar
80
bar
90
bar
100
bar
110
bar
120
bar
130
bar
140
bar
150
bar
725
psi
870
psi
1015
psi
1160
psi
1305
psi
1450
psi
1595
psi
1740
psi
1885
psi
2030
psi
2175
psi
Table 2
Full relief valve configuration setting
0 9 8
Without valve cavity
on both sides
(not drilled)
With valve cavity
plugged (Normally
closed plug)
With anti-cavitation
valve
L M N O P Q R S T U V X
160
bar
170
bar
180
bar
190
bar
200
bar
210
bar
220
bar
230
bar
240
bar
250
bar
270
bar
290
bar
2320
psi
2465
psi
2611
psi
2756
psi
2901
psi
3046
psi
3191
psi
3336
psi
3481
psi
3626
psi
3916
psi
4206
psi
Table 3
LS relief valve configuration setting
Option
selection
Description Standard
setting (bar)
0
without valve cavity -
1
30-90 bar (Setting range) 70
2
80-140 bar (Setting range) 110
3
135-225 bar (Setting range) 180
4
210-310 bar (Setting range) 250
5
290-380 bar (Setting range) 300
9
Normally closed plug R930082023
Note
For pressure higher than 290 bar (4206 psi), contact
factory.
Table 1
Spring Setting
8 bar 11 bar
Spool Variant
3333 28 33
6666 38 45
9999 52 60
1)
1) Considering inlet standby pressure at least 18 bar
Bosch Rexroth AG, RE 18301-35/11.2025
4 EDG-OBE | 4/3 Proportional directional valve elements
Hydraulic layouts
Spool variant
B2 E2
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSB
LSA
General hydraulic layout
Secondary valve types
No secondary valves
00
LS relief valve option
0M
Relief valves with
M0
anticavitation option
Anticavitation
M0
valves option
Combination of
MM
M0 and 0M options
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
Hydraulic layouts
06 - Spool Variants
11 - Secondary valve types
00
No secondary valves
0M
LS relief valves option
M0
Relief valves with
anticavitation option
M0
Anticavitation
valves option
MM
Combination of
M0 and 0M options
Both meter in and out
Spool variant
B2 E2
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSB
LSA
General hydraulic layout
Secondary valve types
No secondary valves
00
LS relief valve option
0M
Relief valves with
M0
anticavitation option
Anticavitation
M0
valves option
Combination of
MM
M0 and 0M options
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
Spool variant
B2 E2
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSB
LSA
General hydraulic layout
Secondary valve types
No secondary valves
00
LS relief valve option
0M
Relief valves with
M0
anticavitation option
Anticavitation
M0
valves option
Combination of
MM
M0 and 0M options
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
Spool variant
B2 E2
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSB
LSA
General hydraulic layout
Secondary valve types
No secondary valves
00
LS relief valve option
0M
Relief valves with
M0
anticavitation option
Anticavitation
M0
valves option
Combination of
MM
M0 and 0M options
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
Spool variant
B2 E2
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSB
LSA
General hydraulic layout
Secondary valve types
No secondary valves
00
LS relief valve option
0M
Relief valves with
M0
anticavitation option
Anticavitation
M0
valves option
Combination of
MM
M0 and 0M options
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
Spool variant
B2 E2
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSB
LSA
General hydraulic layout
Secondary valve types
No secondary valves
00
LS relief valve option
0M
Relief valves with
M0
anticavitation option
Anticavitation
M0
valves option
Combination of
MM
M0 and 0M options
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSBLSA
RE 18301-35/11.2025, Bosch Rexroth AG
4/3 Proportional directional valve elements | EDG-OBE
Functional description
5
Functional description
BA
TBTA
P
TA
TB
A' B'
Y
X
LS
P
XA
XB
LSB
LSA
The EDG OBE pilot operated proportional sectional valves
with pressure compensation controls the oil flow to
actuators with a close loop.
These elements consist of a stackable housing (1) with a
control spool (2), an On Board Electronics (OBE) module
(4), one return spring (3). The OBE module (4) displaces
the control spool from its neutral-central position “0”
proportionally to the current received, with a control in
close loop. When the spool is shifted and the metering
notch is open, flow delivery starts and is controlled by a 2
way pressure compensator (5) (P > A; P > B).
Load pressure compensation
The pressure compensator (5) keeps the pressure
differential on the main spool (2). The flow to the
consumers remains constant, despite varying loads. Port
relief valves with anti-cavitation function on A and B (7)
protect the system against pressure peaks and cavitation.
LS relief valves (6), for each consumer port, can be
adjusted according to specific application requirements.
1 Housing
2 Main spool
3 Return Spring
4 Module coil
5 Compensator spool
6 LS relief valve
7 Secondary valve with
anticavity option
7
7
3
5 2 1 4
6
6
6 7
Bosch Rexroth AG, RE 18301-35/11.2025
6 EDG-OBE | 4/3 Proportional directional valve elements
Technical data
Technical data
General
Valve element
kg (lbs)
2.7 (5.95)
Ambient Temperature °C (°F)
-30...+50 (-22...+122)
Hydraulic
Maximum pressure at P, A and B ports bar (psi) 350 (5000)
Piloting pressure range (X) bar (psi) 12 ÷ 35 (175 ÷508)
Maximum static pressure at T
bar (psi)
210 (3050)
Maximum drain line (Y) back pressure bar (psi) 20 (290)
Max. regulated flow at 8 bar (116 psi)
l/min (gpm)
60 (15.8)
For E schemes symmetrical spool pattern in neutral
position (connection A to T and B to T).
Approx. 2% of the nominal cross-section
Hydraulic fluid
General properties: it must have physical lubricating
and chemical properties suitable for use in hydraulic
systems.
Mineral oil based hydraulic fluids HL (DIN 51524 part 1).
Mineral oil based hydraulic fluids HLP (DIN 51524 part 2).
For use of environmentally acceptable fluids (vegetable or
polyglycol base) please consult us.
Fluid Temperature °C (°F) -30....+100 (-22....+212) (NBR seals)
Permissible degree of fluid contamination ISO 4572: β
x
≥75 X=12...15
ISO 4406: class 20/18/15
NAS 1638: class 9
Viscosity range mm
2
/s 20....380 (optimal 30....46)
Electrical
Voltage range V 8,5 ÷ 30
Maximum current consumption mA 1000
Input signal CAN BUS SAE-J1939
Output signal CAN BUS SAE-J1939
Output spool position signal V 0÷5
Enviromental protection level IP69K
Node ID 0 (default) adjustable
EMC (Emission & Immunity) EN13766 - EN14982
Connector type DT04-6P MALE DEUTSCH
Note
For applications with different specifications consult us.
* In addition to relief valve pressure setting value.
RE 18301-35/11.2025, Bosch Rexroth AG
4/3 Proportional directional valve elements | EDG-OBE
Characteristic curves
7
Characteristic curves
Measured with hydraulic fluid ISO-VG32 at 45° ±5°C
(113° ±9°F); ambient temperature 20°C (68°F).
100 %40 0802 600
60
50
40
30
20
0
10
70
0
2.64
5.28
7.92
10.56
13.2
15.84
18.48
l/min
gpm
Characteristic curves Q=Q(I)
% of maximum CAN-Bus Input Setpoint
Flow - Q
3333
100 %40 0802 600
60
50
40
30
20
0
10
70
0
2.64
5.28
7.92
10.56
13.2
15.84
18.48
l/min
gpm
% of maximum CAN-Bus Input Setpoint
Flow - Q
3333
6666
9999
9999 @18 ba
r
6666
9999
350 bar140 08207 2100
60
50
40
30
20
0
10
70
0
2.64
5.28
7.92
10.56
13.2
15.84
18.48
l/min
gpm
Flow - Q
3333
350 bar140 08207 2100
60
50
40
30
20
0
10
70
0
2.64
5.28
7.92
10.56
13.2
15.84
18.48
l/min
gpm
Flow - Q
3333
6666
9999
9999 @18 ba
r
6666
9999
Load pressure (A/B side) - P
5076 psi2030 16045101 30450
Load pressure (A/B side) - P
5076 psi2030 16045101 30450
Compensation curve Q=Q(A)
2-way inflow controller
Compensation curve Q=Q(A)
2-way inflow controller
Characteristic curves Q=Q(I)
rotasnepmoc lacol rab 11rotasnepmoc lacol rab 8
rotasnepmoc lacol rab 11rotasnepmoc lacol rab 8
Characteristic curves Q=Q(I)
8 bar local compensator
Compensation curve Q=Q(A)
2-way inflow controller
8 bar local compensator
Characteristic curves Q=Q(I)
11 bar local compensator
Compensation curve Q=Q(A)
2-way inflow controller
11 bar local compensator
Bosch Rexroth AG, RE 18301-35/11.2025
8 EDG-OBE | 4/3 Proportional directional valve elements
External dimensions and fittings - Standard version
Dimensions: mm [inches]
External dimensions and fittings - Standard version
98 [3.86]27 [1.06]
16 [0.63]
23.8 [0.94]
32 [1.26]
66 [2.6]
78.5 [3.09]
80.8 [3.18]
A
B
B
3
2
1
1(*)
1
A
2
3
1
P
2
4
1
1
1= 3 mm
2= 10 mm
3= 8.15 mm
4= 6.1 mm
(*)= To be made only for
flange 3 with return Ls
1=O-RING 4.47X1.78
2=O-RING 12X2
3=O-RING 14.0X1.78
4=8.15 mm
(*)= To be made only for
flange 3 with return Ls
5=6.1 mmmm
98
46
4141
78.5
23
16.8
39.5
36.5
44
45.5
19.4
23
42
12.1
28.5
36.8
43
40.9
41.5
Pos. to the coordinates table
Pos. to the coordinates table
0.01
Rz1max 8
0.01
Rz 16
Rz 8
1
A
2
B
2
1
1
1
5
P
3
2
4
4
1(*)
2
41 41
46
Pos. to the coordinates table
2316.8
41.5
40.9
Pos. to the coordinates table
98
78.5
36.5
44
39.5
45.5
5.5
23.1
42
12.1
28.5
36.8
43
min
min
min
min
47 [1.85]
223.4 [8.79]
58.8 [2.32]
112 [4.41]
40 [1.58]
90 [3.54]
98.3 [3.87]
1 Identification label.
2 Flange specifications. For tie rod and tightening torque
information see data sheet RE 18301-92.
2
1
RE 18301-35/11.2025, Bosch Rexroth AG
4/3 Proportional directional valve elements | EDG-OBE
External dimensions and fittings - Emergency Lever option
9
Dimensions: mm [inches]
External dimensions and fittings - Emergency Lever option
External dimensions with lever
106.5 [4.19]56.2 [2.21]
1
4
°
1
4
°
14°
14
°
98 [3.86]71 [2.8]
72.7 [2.86]
36 [1.42]
128.5 [5.06]
162.5 [6.4]
25.1 [0.99]
18.8 [0.74]
40 [1.57]
128.5 [5.06]
173 [6.81]
1
4
°
14°
1
4
°
1
4
°
A
A
B
B
13
∅25
G3/8
∅30
∅20.6
SAE8 - 3/4-16"UNF
15
2.6
∅30
G1/2
15
1
5
°
1.3
0.2
0.2
A
B
G3/8
G1/2
S08
A
B
98.3 [3
.87]
273.3 [10.76]
237.3 [9.34]
10
Bosch Rexroth AG, RE 18301-35/11.2025
Bosch Rexroth Oil Control S.p.A.
Oleodinamica LC Division
Via Artigianale Sedrio, 12
42030 Vezzano sul Crostolo
Reggio Emilia - Italy
Tel. +39 0522 601 801
Fax +39 0522 606 226 / 601 802
compact-hydraulics-cdv@boschrexroth.com
www.boschrexroth.com/compacthydraulics
© This document, as well as the data, specifications and other information
set forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a..
It may not be reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The information given does not release the
user from the obligation of own judgment and verification. It must be
remembered that our products are subject to a natural process of wear and
aging.
Subject to change.
EDG-OBE | 4/3 Proportional directional valve elements
Electric connections
Electric connections
DT04-6P Protection class: IP 69K with connector properly fitted.
6
5
4
1
2
3
DT04-6P MALE DEUTSCH
Connector-Pin OUT
Pin D/C0 VER.
1 +V (Power Supply)
2 CAN-L
3 N.C. (Pos. feedback)
4 N.C. (Analog IN)
5 CAN-H