Bosch Rexroth AG, RE 18301-24/10.2022
2 EDG-PP... | 4/3 and 4/2 Proportional directional valve elements
Ordering details
Ordering details
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18
EDG-PP-_ _ _-_2-_29999-_ __ _-_ _-____
Family
00 Directional Valve elements EDG Size 6 proportional
EDG
Type
01 Electro - Piloted
P
Configuration
02 Proportional
P
Ports & Connections
03 G 3/8 DIN 3852
G38
G 1/2 DIN 3852
G12
3/4-16 UNF 2-B (SAE8)
S08
Local compensator bias spring
04 4 bar (58 psi)
1
6 bar (87 psi)
2
8 bar (116 psi)
3
Flange confi guration
05 With P-TA-TB-LS-Xa-Xb-X-Y lines
2
Hydraulic connections in neutral
06 P, A, B closed LS to T
B
P closed A, B, LS to T
E
Spool variants
07 4/3 operated both sides a and b
2
Flow rates over valve connection (according to table 1)
08 Flow rate P>A
9
09 Flow rate P>B
9
10 Nominal fl ow rate (A>T)
9
5)
11 Nominal fl ow rate (B>T)
9
5)
Voltage supply 03 01
12 12V DC ● ● OB
24V DC ● ● OC
● = Available – = Not available
Electric connections
1)
13
With coils, with connection DIN EN 175301-803 01
1)
With coils, with connection vertical Amp - Junior 03
Secondary valve types
14 Without secondary valve
00
Double or single full relief valve with Anticavitation
(VMA) or anticavitation only (VUM) or plug
M0
3)
Double or single LS relief valve (VMGLS) or plug
0M
4)
Combination of M0 and 0M options together
MM
Secondary valve confi g. setting:
Full Relief or Anticavitation selection (according to table 2)
15 A>Ta setting @5lpm
_
2)
16 B>Tb setting @5lpm
_
2)
Secondary valve confi g. setting: LS Relief (VMGLS)
(according to table 3)
17 LSA>T setting range @1.5lpm
_
2)
18 LSB>T setting range @1.5lpm
_
2)
1) For mating connectors ordering code see data sheet RE 18325-90.
2) "0" option is the only one available for "without secondary valves"
selection.
3) For fi xed setting relief valve data sheet see Data Sheet RE 18329-11.
For anticavitation valve data sheet see Data Sheet RE 18329-51.
4) See Table 3.
5) Only symmetrical spools available.