RE 18301-21/11.2021, Bosch Rexroth AG
4/3 and 4/2 On-Off directional valve elements
EDG-DO...
RE 18301-21
Edition: 11.2021
Replaces: 07.12
4/3 and 4/2 On-Off directional valve elements
with LS
RE 18301-21
Edition: 11.2021
Replaces: 06.2019
General specifi cations
In an assembly EDG block, the inlet section can be
confi gured for either a fi xed displacement pump or
load-sense variable displacement pump. When
simultaneous machine functions are actuated, the pre-
compensators will automatically adjust to the highest
load pressure via a shuttle arrangement, making the
system circuit independent of variations in loads and
pump pressures.
Main Field of Application
▶▶ Truck mounted applications
▶▶ Forestry machinery
▶▶ Forklifts and Telehandler
▶▶ Municipal vehicles
▶▶ Cranes
▶▶ Construction machines
▶▶ Aerial working platforms
▶▶ Heavy duty vehicles
▶▶ Agricultural machines
Size 6
Series 1
Maximum operating pressure:
350 bar (5000 psi) on pump side
350 bar (5000 psi) on consumer side
Maximum fl ow at 6 bar (87 psi) 40 l/min (10.6 gpm)
Ports connections G 3/8 - G 1/2 - SAE6 - SAE8
NEW spool position sensor available for this valve.
See RE18300-30
New Series 1 features:
- Label
- Flange with drain line for VMGLS and combination for
EDG Electrohydraulic actuation
- Lever Manual override option
- Body valve zinc plating treatment for higher corrosion
resistence protection up to 500h
Contents
Ordering details 2
Functional description 5
Technical data 6
Characteristic curves 7
External dimensions and fi ttings 8
Electric connection 11
EDG-DO...
Component Series 1
Bosch Rexroth AG, RE 18301-21/11.2021
2 EDG-DO... | 4/3 and 4/2 On-Off directional valve elements
Ordering details
Ordering details
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20
EDG-DO-_ _ _-_2-______-_ __ _-_ _-____-_ _-1
Family
00 Directional Valve elements EDG Size 6 On-Off
EDG
Type
01 Direct Acting
D
Configuration
02 On-Off
O
Ports & Connections
03 G 3/8 DIN 3852
G38
G 1/2 DIN 3852
G12
9/16-18 UNF 2-B (SAE6)
S06
3/4-16 UNF 2-B (SAE8)
S08
Schäfer DN8-10-STH
R08
Local compensator bias spring
04 4 bar (58 psi)
1
6 bar (87 psi)
2
Flange confi guration
05 With P-TA-TB-LS-Xa-Xb-X-Y lines
2
Hydraulic connections in neutral
06 P, A, B closed LS to T
B
P closed A, B, LS to T
E
Spool variants
07 4/3 operated both sides a and b
2
4/2 operated on side a only
3
4/2 operated on side b only
4
Flow rates over valve connection (from 1 to 9 according to table 1
and table 2)
08 Flow rate P>A
_
09 Flow rate P>B
_
10 Nominal fl ow rate (A>T)
_
6)
11 Nominal fl ow rate (B>T)
_
6)
Voltage supply 07 03 01 00
12 Without coil
–––
00
12V DC
●●●
–OB
24V DC
●●●
–OC
● = Available = Not available
Electric connections
13 Without coils
00
With coils, with connection DIN EN 175301-803
01
1)
With coils, with connection vertical Amp - Junior
03
With coils, with connection horizontal DT04-2P
07
Secondary valve types
14 Without secondary valve
00
Double or single full relief valve with Anticavitation
(VMA) or anticavitation only (VUM) or plug
M0
3)
Double or single LS relief valve (VMGLS) or plug
0M
4)
Combination of M0 and 0M options together
MM
Secondary valve confi g. setting:
Full Relief or Anticavitation selection (according to table 3)
15 A>Ta setting @5lpm
_
2)
16 B>Tb setting @5lpm
_
2)
Secondary valve confi g. setting: LS Relief (VMGLS)
(according to table 4)
17 LSA>T setting range @1.5lpm
_
2)
18 LSB>T setting range @1.5lpm
_
2)
Override option & Emergency Lever
19 Push pin type override
00
Push button override on both sides A and B
EP
Screw type override on both sides A and B
EF
Lever type manual override on A side – Horizontal
5)
HA
Lever type manual override on A side – Vertical
5)
VA
Lever type manual override on A side – Horizontal
5)
180° rotated
H1
Lever type manual override on A side – Vertical
5)
180° rotated
V1
Component Series
20 Series 1
1
1) For mating connectors ordering code see data sheet RE 18325-90.
2) "0" option is the only one available for "without secondary valves" selection.
3) For fi xed setting relief valve data sheet see Data Sheet RE 18329-11.
For anticavitation valve data sheet see Data Sheet RE 18329-51.
4) See Table 4.
5) See page 10.
6) "I" for only meter in option.
RE 18301-21/11.2021, Bosch Rexroth AG
4/3 and 4/2 On-Off directional valve elements | EDG-DO...
Ordering details
3
Ordering details
ABCDEF GHI JK
50
bar
60
bar
70
bar
80
bar
90
bar
100
bar
110
bar
120
bar
130
bar
140
bar
150
bar
725
psi
870
psi
1015
psi
1160
psi
1305
psi
1450
psi
1595
psi
1740
psi
1885
psi
2030
psi
2175
psi
Table 3
Full relief valve confi guration setting
098
Without valve cavity
on both sides
(not drilled)
With valve cavity
plugged (Normally
closed plug)
With anti-cavitation
valve
LMNOPQRSTUVX
160
bar
170
bar
180
bar
190
bar
200
bar
210
bar
220
bar
230
bar
240
bar
250
bar
270
bar
290
bar
2320
psi
2465
psi
2611
psi
2756
psi
2901
psi
3046
psi
3191
psi
3336
psi
3481
psi
3626
psi
3916
psi
4206
psi
Table 1
Notches dimension selection
--> Flow Rate
Local compensator bias spring
4bar 6bar
1 *
3 l/min 5 l/min
2 *
6 l/min 8 l/min
3 *
9 l/min 11 l/min
4 *
13 l/min 14 l/min
6 *
18 l/min 23 l/min
9 *
24 l/min 31 l/min
M *
- 40 l/min
*Note: standard spool types (symmetrical):
1111 - 2222 - 3333 - 4444 - 6666 - 9999 - MMMM
Table 2
Spool size selection guide
P->A
(corresponding A->T same size or "I" size)
Notch size 123469M
P->B
(corresponding B->T same size or "l" size)
1XX
●●●●●
2 XXX◊
●●●
3
XXX◊
●●
4
XXX◊
6
●●
XXX◊
9
●●●
XXX
M
●●●●
◊XX
X
= Standard spool fl ow rate confi guration
= Special spool fl ow rate confi guration, contact factory
= Not available
Table 4
LS relief valve confi guration setting
Option
selection
Description Standard
setting (bar)
0
without valve cavity -
1
30-90 bar (Setting range) 70
2
80-140 bar (Setting range) 110
3
135-225 bar (Setting range) 180
4
210-310 bar (Setting range) 250
5
290-380 bar (Setting range) 300
9
Normally closed plug R930082023
Note
For pressure higher than 290 bar (4206 psi), contact
factory.
Bosch Rexroth AG, RE 18301-21/11.2021
4 EDG-DO... | 4/3 and 4/2 On-Off directional valve elements
Ordering details
= 00 (No secondary valves) = M0 (Relief valve with anticavitation option) = M0 (Anticavitation valve option)
A' B'
TBTA P
A' B'
TBTA P
A' B'
TBTA P
AB AB AB
07 - Spool Variants
14 - Secondary valve types
A' B'
TA
TB
X
Y
P
LS
XA
XB
AB
A' B'
TBTA P
TA
TB
X
Y
P
LS
XA
XB
AB
LSB
LSA
A' B'
TBTA P
TA
TB
X
Y
P
LS
XA
XB
AB
General hydraulic layout
=0M (LS relief valve option) =MM (Combination of M0 and 0M options)
Both meter in and out
B2
TBTA P
A' B'
E2
TBTA P
A' B'
B3
TBTA P
A' B'
E3
TBTA P
A' B'
B4
TBTA P
A' B'
TBTA P
A' B'
E4
Only meter in
B2_ _II
TBTA P
A' B '
E2_ _II
TBTA P
A' B '
B3_ _II
TBTA P
A' B '
E3_ _II
TBTA P
A' B '
B4_ _II
TBTA P
A' B '
TBTA P
A' B '
E4_ _II
RE 18301-21/11.2021, Bosch Rexroth AG
4/3 and 4/2 On-Off directional valve elements | EDG-DO...
Functional description
5
Functional description
The EDG direct acting On-Off solenoid sectional valves with
pressure compensation control the oil fl ow to actuators.
These elements consist of a stackable housing (1) with a
control spool (2), two solenoids (4), two return springs (3).
Each solenoid (4), energized, displaces the control spool
from its neutral-central position. When the spool is shifted,
flow delivery starts and is controlled by a 2 way pressure
compensator(7) (P > A; P > B).
When the solenoid is de-energized, the return spring
pushes the spool back in its neutral-central position.
Each coil (4) is fastened to the solenoid tube by the ring
nut (5). A push-pin manual override is included to actuate
the valve without electrical power as needed.
Load pressure compensation
The pressure compensator (7) keeps the pressure
diff erential on the main spool (2). The fl ow to the
consumers remains constant, despite varying loads.
The highest load pressure on the pump is signaled via the
LS line and the integrated shuttle valve (6).
Port relief valves with anti-cavitation function on A and B
(9) protect the system against pressure peaks and
cavitation. LS relief valves (8), for each consumer port, can
be adjusted according to specifi c application requirements.
1 Housing.
2 Main spool.
3 Return Spring.
4 Coil.
5 Ring nut.
6 LS shuttle valve.
7 Compensator spool.
8 LS relief valve (VMGLS)
9 Secondary valve with
anticavitation option.
AB
TBTA P
LSB
LSA
TA
TB
XA
P
LS
XB
X
Y
A' B'
99
6
8
2
7
8
99
7
54
6
435
88
21
89
Bosch Rexroth AG, RE 18301-21/11.2021
6 EDG-DO... | 4/3 and 4/2 On-Off directional valve elements
Technical data
Technical data
General
Valve element with 2 solenoids kg (lbs) 2.2 (4.85)
Valve element with 1 solenoid kg (lbs) 1.7 (3.75)
Ambient Temperature °C (°F) -30....+90 (-22....+194)
Hydraulic
Maximum pressure at P, A and B ports bar (psi) 350 (5000)
Maximum static pressure at T bar (psi) 210 (3050)
[in case of Emergency Lever option, max. pressure is limited up to
30 bar at T]
Max. regulated fl ow at 6 bar (87 psi) l/min (gpm) 40 (10.6)
For E schemes symmetrical spool pattern in neutral position
(connection A to T and B to T) E-schemes fl ow pattern with only meter
IN (spool type E_ _ _ I I)in neutral position: the opening area is approx
the 50% of nominal cross-section. This spool type is suitable in
combination with load holding valves applications.
Approx. 2% of the nominal cross-section
Hydraulic fl uid
General properties: it must have physical lubricating
and chemical properties suitable for use in hydraulic
systems.
Mineral oil based hydraulic fl uids HL (DIN 51524 part 1).
Mineral oil based hydraulic fl uids HLP (DIN 51524 part 2).
For use of environmentally acceptable fl uids (vegetable or
polyglycol base) please consult us.
Fluid Temperature °C (°F) -30....+100 (-22....+212) (NBR seals)
Permissible degree of fl uid contamination ISO 4572: β
x
≥75 X=12...15
ISO 4406: class 20/18/15
NAS 1638: class 9
Viscosity range mm
2
/s 20....380 (optimal 30....46)
Electrical
Voltage type DC
Voltage tolerance (nominal voltage) % -10....+10
Duty Continuous, with ambient temperature ≤ 50° (122°F)
Coil wire temperature not to be exceeded °C (°F) 180 (356)
Insulation class H
Compliance with Low Voltage Directive LVD 73/23/EC (2006/95/EC), 2004/108/EC
Coil weight kg (lbs) 0.228 (0.503)
Voltage V 12 24
Power consumption W 20 20
Current (nominal at 20°C (68°F)) A 1.04 0.54
Resistance (nominal at 20°C (68°F)) Ω 7.4 28.4
Note
For applications with diff erent specifi cations consult us
Code Voltage [V] Connector type Coil description Marking Coil Mat no.
=OB 01
12 DC EN 175301-803 (Ex. DIN 43650) D3601 12DC 12 DC R901393412
=OB 03
12 DC AMP JUNIOR D3603 12DC 12 DC R901435507
=OB 04
12 DC AMP JUNIOR Horizontal D3604 12DC 12 DC R901395031
=OB 07
12 DC DEUTSCH DT 04-2P D3607 12DC 12 DC R901394397
=OC 01
24 DC EN 175301-803 (Ex. DIN 43650) D3601 24DC 24 DC R901393577
=OC 03
24 DC AMP JUNIOR D3603 24DC 24 DC R901435494
=OC 04
24 DC AMP JUNIOR Horizontal D3604 24DC 24 DC R901395035
=OC 07
24 DC DEUTSCH DT 04-2P D3607 24DC 24 DC R901394399
RE 18301-21/11.2021, Bosch Rexroth AG
4/3 and 4/2 On-Off directional valve elements | EDG-DO...
Characteristic curves
7
Characteristic curves
Measured with hydraulic fl uid ISO-VG32 at 45° ±5°C
(113° ±9°F); ambient temperature 20°C (68°F).
Performance limits
()
()
Bosch Rexroth AG, RE 18301-21/11.2021
8 EDG-DO... | 4/3 and 4/2 On-Off directional valve elements
External dimensions and fi ttings
Dimensions [mm (inches)]
External dimensions and fi ttings
1 Ring nut for coil locking (Ø 30.3 mm).
Torque 6 – 7 Nm (4.4 – 5.2 ft-lb).
2 Flange specifications. For tie rod and tightening torque
information see data sheet RE 18301-90.
3 A and B ports.
4 Identification label.
5 Optional push-button manual override, EP type, for spool opening:
it is pressure stuck to the ring nut for coil locking.
Mat no. R930059524
6 Optional screw type manual override, EF type, for spool opening:
it is screwed (torque 6-7 Nm (4.4-5.2 ft-lb)) to the tube as
replacement of the coil ring nut. Mat no. R930059561.
4
1
3 3
()
()
()
()
Ø 13 (0.51)
Ø 13.8 (0.54)
Ø 19 (0.75)
Ø 16.9 (0.66)
()
()()
()
()
()
()
()
()
()
()
29,5
5)
33
25
6)
61,2
=G38
=S08
=R08
=S06
=G12
2
RE 18301-21/11.2021, Bosch Rexroth AG
4/3 and 4/2 On-Off directional valve elements | EDG-DO...
External dimensions for spool with nominal fl ow M
9
Dimensions [mm (inches)]
External dimensions for spool with nominal fl ow M
1 Flow-boost system only for spool with nominal fl ow M.
It always mounted on "a" side of the valve.
Bosch Rexroth AG, RE 18301-21/11.2021
10 EDG-DO... | 4/3 and 4/2 On-Off directional valve elements
Lever type manual override available on A side only
Dimensions [mm (inches)]
Lever type manual override available on A side only
3
4
1
2
() ()
()
()
()
()
()
()
()
()
()
()
1 Order detail: HA Horizontal lever manual override option
2 Order detail: VA Vertical lever manual override option
3 Order detail: H1 Horizontal lever manual override option, 180°
rotated
4 Order detail: V1 Vertical lever manual override option, 180°
rotated
Note
Not possible to switch from HA or VA to H1 or V1 and
viceversa.
RE 18301-21/11.2021, Bosch Rexroth AG
4/3 and 4/2 On-Off directional valve elements | EDG-DO...
Electric connection
11
Dimensions [mm (inches)]
Electric connection
00
Without coil
01
Protection class: IP 65 when connector
with seal is properly screwed down.
()
()
()
()
()
(
)
03
Protection class: IP 65 with female connector
properly fi tted (see drawing).
07
Protection class: IP 69 K with female connector
properly fi tted (see drawing).
()
()
()
()
()
()
()
()
()
()
()
()
()
()
12
Bosch Rexroth AG, RE 18301-21/11.2021
Bosch Rexroth Oil Control S.p.A.
Oleodinamica LC Division
Via Artigianale Sedrio, 12
42030 Vezzano sul Crostolo
Reggio Emilia - Italy
Tel. +39 0522 601 801
Fax +39 0522 606 226 / 601 802
compact-hydraulics-cdv@boschrexroth.com
www.boschrexroth.com/compacthydraulics
© This document, as well as the data, specifi cations and other information
set forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a..
It may not be reproduced or given to third parties without its consent.
The data specifi ed above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The information given does not release the
user from the obligation of own judgment and verifi cation. It must be
remembered that our products are subject to a natural process of wear and
aging.
Subject to change.
EDG-DO... | 4/3 and 4/2 On-Off directional valve elements
Electric connection