4/8 HED 5 | Pressure Switch
Bosch Rexroth AG, RE 50056, edition: 2016-09
Technical data
(For applications outside these parameters, please consult us!)
Hydraulic
Pressure rating bar 50 100 200 350
Max. operating
pressure
▶ NBR/FKM seals bar 350 350 350 400
▶ MT version bar 315 315 315 315
Pressure adjustment range (decreasing) bar 5...50 10...100 15...200 25...350
Pressure differential per rotation
1)
bar ≈10 ≈17 ≈38 ≈60
Hydraulic fluid
1)
see table below
Hydraulic fluid temperature range
(at the valve operating ports)
°C –30 … +80 (NBR seals)
–20 … +80 (FKM seals)
–40 … +80 (low-temperature seals)
Viscosity range mm
2
/s 10 … 800
Maximum permissible degree of contamination of the hydraulic fluid,
cleanliness class according to ISO 4406 (c)
Class 20/18/15
2)
Load cycles ≥ 4 million
General
Mass kg 0,2
Installation position any
Ambient temperature range °C –30 to +50 (NBR seals)
–20 to +50 (NBR seals)
–40 to +50 (low-temperature seals)
Sine test according to DIN EN 60068-2-6:1996-05 10...2000 Hz, max. 10 g, 10 double cycles
Transport shock according to DIN EN 60068-2-27:1995 03 Half-sine 15 g / 11 ms,
3 x in positive direction, 3 x negative direction
(a total of 6 single shocks per axis)
Noise test according to DIN EN 60068-2-64:1995-08 20...2000 Hz, 14 g
RMS
, 24 h
Conformity ▶ CE DIN EN 61058-1: 2002 / A2: 2008
DIN EN 60947-1: 2007 / A1: 2011
DIN EN 60947-5-1: 2004 / A1: 2009
DIN EN 60529: 1991 / A2: 2013
▶ UL UL 508 17th edition File No E223220 (up to 350bar)
▶ CCC GB 14048.5-2008
Hydraulic fluid Classification Suitable
sealing materials
Standards Data sheet
Bio-degradable HL, HLP, HLPD, HVLP, HVLPD NBR, FKM, low-temperature
seals
DIN 51524 90220
Bio-degradable ▶ Insoluble in water HETG NBR, FKM ISO15380 90221
HEES FKM
▶ Soluble in water HEPG FKM ISO15380
Schwerentflammbar ▶ Water-free HFDU, HFDR FKM ISO 12922 90222
▶ Containing water HFC (Fuchs Hydrotherm 46M,
Petrofer Ultra Safe 620)
NBR ISO 12922 90223
Important information on hydraulic fluids:
▶ For more information and data about the use of other hydraulic
fluids, refer to data sheets above or contact us!
▶ There may be limitations regarding the technical valve data (tempe
-
rature, pressure range, life cycle, maintenance intervals, etc.).
▶ The flash point of the hydraulic fluid used must be 40 K higher
than the maximum solenoid surface temperature.
▶ Flame-resistant – contains water:
– Maximum pressure differential per control edge 50bar
– Pressure pre-loading at the tank port > 20% of the pressure
differential, otherwise increased cavitation
– Life cycle as compared to operation with mineral oil HL,
HLP 50 to 100%
▶ Bio-degradable and flame-resistant: When using these hydraulic
fluids that are simultaneously zinc-solving, zinc may accumulate
(700mg zinc per pole tube).