RE 18324-64/02.2019, Bosch Rexroth Oil Control S.p.A.
Solenoid operated valves direct acting spool
4-way 3-position
Common cavity, Size 10
RE 18324-64
Edition: 02.2019
Replaces: 05.2016VEDS-10A-43 OD.14 - X - 78 - KK2 - Y - 00
Technical data
General
Weight (with coils) 0.85kg (1.87lbs)
Installation position Any
Ambient temperature range -40 to 110°C (-40 to 230°F)
Salt spray test to DIN 50021 720 h
Hydraulic
Max. operating pressure
port 2, 3, 4
350bar (5075psi)
Max. operating pressure
port 1
250bar (3625psi)
Max. flow 35 l/min. (9 gpm)
Max. internal leakage < 60 ml/min. (with Δp=250
bar; HLP46, T
oil
= 40°C)
Fluid temperature range -40 to 80°C (-40 to 176°F)
Fluids: Mineral-based or synthetics with lubricating properties at
viscosities of 5 to 1000 mm
2
/s (preferably 10 to 100 mm
2
/s)
Recommended degree
of fluid contamination
Nominal value max. 10µm
(NAS 8) ISO 4406 19/17/14
Cavity CA-10A-4N see 18325-70
Seal kit material no. R961005190
Load cycles 2 Mio.
Electrical
Type of voltage DC voltage
Coil type GZ37 see 18325-90
Note: coils must be ordered separately.
Version 10 Version 40
Version 20 Version 60
Bosch Rexroth Oil Control S.p.A., RE 18324-64/02.2019
2 VEDS-10A-43 | Solenoid operated valves direct acting spool 4-way 3-position
Ordering code
OD14 X 78 KK2 Y 0 0
Solenoid operated valves direct acting spool
4-way 3-position
Version 10
Version 20
Version 40
Version 60
without manual override 0
with pull/push manual override 1
Preferred types
Type Material number
OD141078KK2000 R901237595
OD142078KK2000 R901237594
OD144078KK2000 R901237592
OD146078KK2000 R901237591
Type Material number
OD141078KK2100 R901255425
OD142078KK2100 R901255421
OD144078KK2100 R901255423
OD146078KK2100 R901255424
RE 18324-64/02.2019, Bosch Rexroth Oil Control S.p.A.
Solenoid operated valves direct acting spool 4-way 3-position | VEDS-10A-43 02.2019 3
Characteristic curves
Version 10 Version 20
Version 40 Version 60
Version 10 - Limits of performance Version 20 - Limits of performance
Version 40 - Limits of performance Version 60 - Limits of performance
Voltage range and duty cycle depending on the ambient temperature
1 Max. voltage
2 Duty cycle
3 Min. response voltage
Admissible supply voltage range
4
Bosch Rexroth Oil Control S.p.A., RE 18324-64/02.2019
Bosch Rexroth Oil Control S.p.A.
Via Leonardo da Vinci 5
P.O. Box no. 5
41015 Nonantola – Modena, Italy
Tel. +39 059 887 611
Fax +39 059 547 848
compact-hydraulics-cv@boschrexroth.com
www.boschrexroth.com/compacthydraulics
© This document, as well as the data, speci▼cations and other information set
forth in it, are the exclusive property of Bosch Rexroth Oil Control S.p.a.. It
may not be reproduced or given to third parties without its consent. The data
speci▼ed above only serve to describe the product. No statements concerning
a certain condition or suitability for a certain application can be derived from
our information. The information given does not release the user from the
obligation of own judgment and veri▼cation. It must be remembered that our
products are subject to a natural process of wear and aging. Subject to change.
VEDS-10A-43 | Solenoid operated valves direct acting spool 4-way 3-position
Dimensions [mm (inches)]
Dimensions
Solenoid operated valves direct acting spool 4-way 3-position
0 1