is a member of the
of companies
www.bifold.co.uk
BFD87 November‘13
© Bifold 2013
FP01 Solenoid Valve Range
4
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please
refer to the product catalogue issue list on our web site or
contact a member of our sales team.
When selecting a product, the applicable operating system
design must be considered to ensure safe use. The products
function, material compatibility, adequate ratings, correct
installation, operation and maintenance are the
responsibilities of the system designer and user.
Quality Assurance
All Bifold products are manufactured to a most stringent
QA programme to ensure that every product will give optimum
SHUIRUPDQFHDQGUHOLDELOLW\:HDUHWKLUGSDUW\FHUWLÀHGWR
%6(1,62)XQFWLRQDOWHVWFHUWLÀFDWHOHWWHURI
FRQIRUPLW\DQGFRSLHVRIRULJLQDOPLOOFHUWLÀFDWHVSURYLGLQJ
total traceability are available on request, to BS EN 10204 3.1
where available. We reserve the right to make changes
WRWKHVSHFLÀFDWLRQVDQGGHVLJQHWFZLWKRXWSULRUQRWLFH
Preferred Range
Product
Schematic
Representation
Page
Number
Product Code
Product Description
13
13
13
13
DIRECT ACTING SOLENOID VALVES - PREFERRED RANGE
FP01
S1
FP01
S1
Manual Reset
FP01
S2
FP01
S2
Manual Reset
†
FP01/S1/M/32/NC/S/74AT4-24D/36
FP01/S2/M/32/NC/S/74AT4-24D/36
FP01/S1/M/32/NC/S/77A-24D/30
FP01/S2/M/32/NC/S/77A-24D/30
FP01/S1/M/32/NC/S/78A-155
FP01/S2/M/32/NC/S/78A-155
FP01/S1/M/32/NC/S/74AT4-24D/ML/36
FP01/S2/M/32/NC/S/74AT4-24D/ML/36
FP01/S1/M/32/NC/S/77A-24D/ML/30
FP01/S2/M/32/NC/S/77A-24D/ML/30
FP01/S1/M/32/NC/S/78A-155/ML
FP01/S2/M/32/NC/S/78A-155/ML
ATEX II 2 GD c, Ex emb IIC T4 Gb
ATEX II 2 GD c, Ex emb IIC T4 Gb
ATEX II 2 GD, Ex d IIC T6
ATEX II 2 GD, Ex d IIC T6
ATEX II I GD, Ex ia IIC T6 Ga
ATEX II I GD, Ex ia IIC T6 Ga
IECEx Ex emb IIC T4 Gb
IECEx Ex emb IIC T4 Gb
IECEx Ex d IIC T6
IECEx Ex d IIC T6
IECEx Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
3.6 Watt, Cv 0.01, 345 bar.
3.6 Watt, Cv 0.01, 517 bar.
3.0 Watt, Cv 0.01, 345 bar.
3.0 Watt, Cv 0.01, 517 bar.
3 way 2 position, direct acting, Normally
Closed, 24Vdc, Auto Reset.
3 way 2 position, direct acting, Normally
Closed, 24Vdc, Auto Reset.
3 way 2 position, direct acting, Normally
Closed, Auto Reset.
3 way 2 position, direct acting, Normally
Closed, 24Vdc, Auto Reset.
3 way 2 position, direct acting, Normally
Closed, 24Vdc, Auto Reset.
3 way 2 position, direct acting, Normally
Closed, Auto Reset.
ATEX II 2 GD c, Ex emb IIC T4 Gb
ATEX II 2 GD c, Ex emb IIC T4 Gb
3.6 Watt, Cv 0.01, 345 bar.
3.6 Watt, Cv 0.01, 517 bar.
3 way 2 position, direct acting, Normally
Closed, 24Vdc, Manual Reset.
3 way 2 position, direct acting, Normally
Closed, 24Vdc, Manual Reset.
3 way 2 position, direct acting, Normally
Closed, Manual Reset.
3 way 2 position, direct acting, Normally
Closed, 24Vdc, Manual Reset.
3 way 2 position, direct acting, Normally
Closed, 24Vdc, Manual Reset.
3 way 2 position, direct acting, Normally
Closed, Manual Reset.
ATEX II 2 GD, Ex d IIC T6
ATEX II 2 GD, Ex d IIC T6
IECEx Ex d IIC T6
IECEx Ex d IIC T6
3.0 Watt, Cv 0.01, 345 bar.
3.0 Watt, Cv 0.01, 517 bar.
†
†
†
ATEX II I GD, Ex ia IIC T6 Ga
ATEX II I GD, Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
IECEx Ex ia IIC T6 Ga
155 Ohms, Cv 0.01, 345 bar.
155 Ohms, Cv 0.01, 517 bar.
155 Ohms, Cv 0.01, 345 bar.
155 Ohms, Cv 0.01, 517 bar.
IECEx Ex emb IIC T4 Gb
IECEx Ex emb IIC T4 Gb
† Solenoid must be used in conjunction with a correctly matched Intrinsically Safe (IS) solenoid driver. The valve installer is responsible for a correct and safe IS system.
VALVE LIMITS
1
2
3
VALVE LIMITS
1
2
3
VALVE LIMITS
1
2
3
VALVE LIMITS
1
2
3