Hydraulic uid mineral oil according to DIN 51524 (other uids on request)
Fluid temperature range 20 bis 80 °C
Ambient temperature range 30 to 50 °C
Viscosity range 5 to 400 mm
2
/s
Porting NG 6 according to DIN 24340 / ISO 4401 / CETOP RP 121 H
Nominal pressure stages 315 bar, 400 bar, 550 bar, 700 bar
Max. operating pressure connection P, A, B 700 bar
Max. operating pressure connection T 70 bar
Max. ow rate directly operated: 8 l/min / pilot operated: 25 l/min
Filtration (recommendation) according to NAS 1638 class 6 or ISO/DIN 4406 17/15/12
Duty cycle DC 100%
Solenoid voltage (nominal resistance) 24 VDC (5 Ohm)
Degree of protection IP 65 according to EN 60529 / DIN 40050
Weight directly operated: 2 kg / pilot operated: 3 kg
Dither frequency (recommendation) 60 - 400 Hz
Hysterese 5 % with optimal dither signal
Material valve body: stainless steel
Ssolenoid coil: ZnNi-plated (1000 h salt spray test)
Technical data
Electrical control of supply or working pres-
sure in open or closed control loop:
remote pressure setting
maintaining pressure within small limits,
independent of disturbance
generating any pressure time curves
Pre-relief of large volumes
Applications
Directly operated with wide useful range
Pilot operated for high ow rate
High degree of pressure stability
Linear pressure-current characteristic
External tank connection option with
automatic disconnection of the directly
operated valve from the system tank line
Features
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Proportional pressure relief valves
Design
Easy-running proportional solenoid with 360° rotatable and replaceable
plug-in coil
Low friction, direct force transmission to the valve needle
Manual override for manual function test
The pilot operated valve consists of the direct operated valve, main stage
and end plate
The orices of the main stage are easily exchangeable
2/9
-
-
-
-
-
- -
00C
P
6I
V
8
24
400
PDB
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Design revision
For internal purposes
Index
Please leave blank
For internal purposes
Design
00 ... 99
For internal purposes
Control method 24 solenoid 24 VDC
Seal material V FKM
other seal materials on request
Nominal pressure stage 315 bar
400 bar
550 bar
700 bar
Max. ow rate 8 l/min directly operated
25 l/min pilot operated
Nominal size 6 ...
Connection ISO ... I
Pressure relief P In connection P
Proportional pressure relief valve
Example
Type code
3/9
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Max. operating pressure 315 bar 400 bar 550 bar 700 bar
Max. ow rate 8 l/min
Part No. 4487130 4487227 4487226 4487214
Symbol
Max. ow rate 25 l/min
Part No. 4590611 4590612 4590613 4590614
Symbol
Product information
Orice
Orice
*
* Internal check valve ensures automatic disconnection of the system tank line when using the side tank outlet
*
**
** Plug (
3778885)
enclosed loose. Only install if the external tank connection of the main stage is used.
4/9
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Dimensional drawings
Pilot operated
Directly operated
5/9
(Q = 1 l/min)
0
100
200
300
400
500
600
700
800
0 200 400 600 800 1000 1200 1400 1600
p [ bar ]
I [ mA ]
700 bar
550 bar
400 bar
315 bar
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Pressure p(I, nominal pressure stage)
Drilling pattern
6/9
0
100
200
300
400
500
600
700
800
0 2 4 6 8
p [ bar ]
Q [ l / min ]
700 bar
550 bar
400 bar
315 bar
0
100
200
300
400
500
600
700
800
0 5 10 15 20 25
p [ bar ]
Q [ l / min ]
700 bar
550 bar
400 bar
315 bar
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Pressure p(Q, nominal pressure stage)
Directly operated
Pilot operated
7/9
0
2
4
6
8
10
12
0 5 10 15 20 25
p [ bar ]
Q [ l / min ]
1.0
10.0
100.0
0.1 1 10
p [bar]
Q [ l/min ]
700 bar
550 bar
400 bar
315 bar
200
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Minimum pressure pmin(Q, nominal pressure stage)
Directly operated
Pilot operated
all nominal pressure stages
8/9
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Accessories
Part description Type code Part No.
Screw-in orice Ø 0.2 (for mounting in the P connection)
BL700-6-D5,5-0,2-A*00 3688087
Screw-in orice Ø 0.3 (for mounting in the P connection)
BL700-6-D5,5-0,3-A*00 3985507
Screw-in orice Ø 0.4 (for mounting in the P connection)
BL700-6-D5,5-0,4-A*00 3891841
Screw-in orice Ø 0.5 (for mounting in the P connection)
BL700-6-D5,5-0,5-A*00 3688099
Screw-in orice Ø 0.6 (for mounting in the P connection)
BL700-6-D5,5-0,6-A*00 3985546
Screw-in orice Ø 0.7 (for mounting in the P connection)
BL700-6-D5,5-0,7-A*00 3985547
Screw-in orice Ø 0.8 (for mounting in the P connection)
BL700-6-D5,5-0,8-A*00 3985549
Screw-in orice Ø 0.9 (for mounting in the P connection)
BL700-6-D5,5-0,9-A*00 3985550
Part description For valve type Part No.
1 x Plug for solenoid grey all 6132484
1 x Plug for solenoid black all 3728850
4 x Socket head screw ISO 4762-M5 x 60-12.9 directly operated 4576469
4 x Tie bolt, M5 x 152-12.9 pilot operated 4455766
4 x Special hexagonal nut-M5 x 2d-12 pilot operated 4455768
Dimensional drawing Symbol
Spare parts
Part description For valve type Part No.
4 x O-ring, 9.25 x 1.78, FKM all 4455692
1 x Plug (
when using external T-connection
) all 3778885
1 x Solenoid coil 24 VDC all 4356848
1 x Pole tube nut all 914559
1 x O-ring for pole tube nut all 616992
1 x Plug for external T-connection all 613141
For pressure relief valves see technical data sheet DB500/700/1000.
Other mounting screws, tie bolts and subplates see technical data sheet
AP700/RP700/EP700.
Bieri Hydraulik AG
Könizstrasse 274
CH-3097 Liebefeld
Tel. +41 31 970 09 09 | Fax +41 31 970 09 10
info@bierihydraulics.com | www.bierihydraulics.com
9/9
The information in this brochure relates to the operating condi-
tions and applications described.
For applications and operating conditions not described, ple-
ase contact the relevant technical department.
Subject to technical modications.
Type PDB-6I
NG 6 ISO
up to 25 l/min, up to 700 bar
Safety
We recommend to operate the proportional pressure relief
valves only in combination with a separate pressure relief
valve to limit the pressure to the max. allowed value.
Open loop control (without actual system pressure feedback)
manual adjustment of the actual pressure
pressure adjustment with manual operated potentiometer or PLC-control
Closed loop control (with actual system pressure or force feedback)
for automatic adjustment of system pressure to the pre-selected pressure
for pressure setting with PLC, manual operated potentiometer or via BUS-system
Electronic controllers (available from HYDAC)
Electronic selection table
PDB-6I_10000548360_EN_34L23
design
HYDAC Part No.
HYDAC ordering code
amplier mode („open loop control“)
controller mode („closed loop control“)
setpoint signal 0 ...10 V
setpoint signal 4 … 20 mA
coupling via iO-Link
oscilloscope function
resolution (% current range)
solenoids in sectable form indep.
status monitoring control range
accessoires for the parameterization
Amplier
connector
6112594 EHCD-AP011XXXD 0,1 1
Interface box for amplier
connector
(HYDAC - EHCD-APIFB) =
6108514
6108508 EHCD-AP012XXXD 0,1 1
Snap in
module
according
EN50022
6158999 EHCD-AM005XXXU 0,01 2
USB-cable Typ B
(Standard printer cable)
6249389
6174133 EHCD-CUPREXAXPA 0,006 1
6174135 EHCD-CUPREXHXPA 0,0025 1
6269387 EHCD-CUPR2LAXPA 0,01 2