Nivotemp NT 61, NT 61D, NT 61-HT
Technical Data NT 61-HT
Basic Unit
Operating pressure max. 1 bar
last contact
55L
L2 = min. 70
L1 = min. 30
with VA stilling
tube
min. 60*
Rubberised cork
seal
1st contact
*min 80 with temperature
4
8
Ø51
3.5
min. Ø60
57
Ø60*
6x Ø6
Ø73
Ø90
*min. Ø61 for VA version with
stilling tube
Operating temperature -20 °C to +80 °C
Float SK 221
Min. fluid density 0.85 kg/dm³
Lengths (all versions) 280, 370, 500 mm (Standard), variable to max. 1500 mm
in 10 mm increments
Material/Version
Float 1.4571
Immersion tube 1.4571
Flange (DIN 24557) 1.4571
Weight at L=280 mm
Each 100 mm add
approx. 950 g
approx. 50 g
Includes:
Mounting screws (quantity 6) and rubberised cork seal.
Options
Stilling tube (SSR) Same material as immersion tube
Level switching contact
K10 W11 K10HT** W11HT**
Function NO/NC* Change-over
contact
NO/NC* Change-over
contact
Voltage max. 230 V AC/DC 48 V AC/DC 230 V AC/DC 48 V AC/DC
Switching current max. 0.5 A 0.5 A 0.5 A 0.5 A
Contact load max. 10 VA 20 VA 10 VA 20 VA
Min. contact spacing 40 mm 40 mm 40 mm 40 mm
Operating temperature 105 °C 105 °C 150 °C 150 °C
Contact position in 10 mm increments
*NO= falling NC contact / NC = falling NO contact **HT= not adjustable
Optional temperature switching outputs
Temperature contact TK TM
Number of temp. contacts 1 2
Voltage max. 230 V AC/DC 230 V AC/DC
Switching current max. 2.5 A 2 A
Contact load max. 100 VA 100 VA
Function NC* NC*
Switching point °C 50/60/70/80 50/60/70/80
Switching point tolerance ± 3 K ± 5 K
Hysteresis max. 10 K ± 3 K 18 K ± 5 K
Function NO* NO*
Switching point °C 50/60/70/80 50/60/70/80
Switching point tolerance ± 3 K ± 5 K
Hysteresis max. 10 K ± 3 K 26/35/40/45 K ± 5 K
*NO = NO contact / NC = NC contact Data for rising temperature. Other temperatures and version
with 2 x TK contact available upon request.
Optional temperature signal
Temperature sensor
Pt 100
Class B, DIN EN 60 751 Tolerance ±0.8 °C
Temperature transmitter KT
Temperature sensor Pt100 Class B, DIN EN 60 751
Measuring range 0 °C to +100 °C
Operating voltage (U
B
) 10 - 30 V DC
Output 4 - 20 mA
Burden Ω max. = (U
B
-7.5 V) / 0.02 A
Accuracy ± 1 % from end value
Other measuring ranges available upon request
8 Bühler Technologies GmbH We reserve the right to amend specification. DE100208 ◦ 09/2023