419024
8,5
73
50
50,520,5
25
130
4,5
40,8
A
B
P-IN
DR
LS
1,5 - 85 l/min
- Turn screw "R" anti-clockwise
to increase regulated flow.
- Drain flow when de-energized 2 l/min.
- Max back pressure admitted on
"DR" line 1,5 bar.
- For correct operation 8-9 bar must be
present in port A. For open centre or
low pressure systems a 9 bar check
valve should be fitted in port A .
- Spool switching can be influenced by
flexing or stressing the valve body. It is
recommended to fit spacers on the
mounting bolts between the valve and
the mounting surface.
-See chapter four for suitable check valves.
Coil to be ordered separately
1
3
2
12,5
22
13
41
Locknut
13 Nm
"R"
Hex. 4
4
73,5
20
40 19
9
N°3 Holes
56,5
38
20
MFPT-100-MHAR
Zinc plated steel
P-IN, A,B
: G 1/2"
DR,LS
: G 1/4"
200
100 - 200
75
PRESSURE COMPENSATED PRIORITY
FLOW REGULATOR FOR
AUXILIARY CIRCUITS
FLOW - Q (l/min)
0 50 10075
0
2
4
6
8
25
10
PRESSURE
∆p (bar)
MF000054
MFPT-100-MHAR-85-G12-N350
P-IN, A,B
: G 1/2"
DR,LS
: G 1/4"
165
150 - 350
350
PA - PB
(bar)
PA > PBPB > PA
Priority flow
Q (l/min)
160
140
120
100
100 15050
-250 -200 -100
0
20
0
40
60
80
-50
200
-150
LS
(Excess flow)
B
A
(Priority flow)
(inlet flow)
P-IN
DR
(Drain)
1
2
3
4
PB>9 bar
3,4 kg
SPECIFICATIONS
ORDERING CODES
Max. operating pressure:
Rated flow:
Weight:
FLOW REGULATOR
Manifold:
Atlantic
Fluid Tech
Quick
code
Description
Main ports size
Setting
range
(bar)
MF000053
MFPT-100-MHAR-85-G12-N210
350 bar
100 l/min
NOTES
Standard
setting
(bar)
Adjustment
(bar/turn)
Regulated Flow:
Coil:
M7