8
OVERALL DIMENSIONS
Max. operating pressure ports A/B /P (*) 250 bar
Regulated flow rate 75 / 105 l/min
Decompression drain flow max 0,7 l/min
Relative duty cycle Continuous 100% ED
Type of protection (in relation to the connector used) IP 65
Flow rate gain See diagram "Input signal flow"
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -20°C ÷ 75°C
Ambient temperature -20°C ÷ 60°C
Max. contamination level from class 7 to 9 in accordance
with NAS 1638 with filter ß
10
≥75
Weight 4,97 Kg
Type of voltage 9V 12V 24V
Max. current
2.33A 2.5 A 1.25 A
Solenoid coil resistance at 20°C (68°F) 2.85 Ohm 11.4 Ohm
Hysteresis with ∆p 7 bar
~ 5% <5% <8%
Response to step ∆p = 7 bar (P/A)
0 ÷ 100% ~ 65 ms -
100% ÷ 0 ~ 30 ms -
Frequency response -3db (Input signal 50% ± 25% Vmax.)
7Hz -
OPERATING SPECIFICATIONS
XQP.5. OPEN LOOP 2/3 WAY PROPORTIONAL PRESSURE
COMPENSATED
FLOW REGULATORS
CETOP 5
AMPLIFIER UNIT AND CONTROL
REM.S.RA.*.*...
Electronic regulator for control single propor-
tional solenoid valve
E = Manual override
GSQ = Square section seal
Support plane
specifications
Fixing screws UNI 5931 M6x40
(12.9 material screws are recommended)
Tightening torque 8 ÷ 10 Nm / 0.8 ÷ 1 Kgm
(*) Pressure dynamic allowed for 2 millions of
cycles. T ports closed on the subplate.
Operating specifications are valid for fluids
with 46 mm
2
/s viscosity at 40°C, using speci-
fied ARON electronic control units.
Performance data are carried out using the
specified Aron power amplifier type
REM.S.RA... power supplied at 24V.
"D19P"
P
ROPORTIONAL SOLENOIDS
Type of protection (in relation to connector used) IP 65
Ambient temperature -54°C ÷ 60°C
Duty cycle 100% ED
Insulation class wire H
Weight 1,58 Kg
ETD19P - 01/2002/e