File: XQP3002_E 01 /2010/eVIII 20
8
HYDRAULIC SYMBOLS
ORDERING CODE
The open loop proportional flow regulator is 2 and 3 way compensated with priority function.
It is designed to regulate flow in proportion to an applied electrical current (REM or SE3AN
power amplifier). Flow regulation is load independent - B port. Load compensation is achieved
by a spool compensator which holds the pressure drop constant across the proportional spool.
XQP.3... OPEN LOOP 2/3 WAY PROPORTIONAL PRESSURE
COMPENSATED
FLOW REGULATORS
XQP Open loop 2/3 way
proportional compensated
flow regulator
3 CETOP 3/NG6
C 2/3 way compensation
with priority function
3 3 way version (standard)
For to obtain 2-way version the P line
must be closed on the subplate
* Nominal flow rates
F = 6 l/min
G = 12 l/min
H = 22 l/min
I = 32 l/min
L = 40 l/min
* S = without decompression
D = with decompression
* Max. current to solenoid
E = 2.35 A
F = 1.76 A
G = 0.88 A
** 00 = No variant
P1 = Rotary emergency
P5 = Rotary emergency 180°
V1 = Viton
2 Serial No.
The fluid used is a mineral based oil with a viscosity of 46 mm
2
/s at 40°C.
The tests have been carried out at with a fluid of a 40°C.
SIMPLIFIED TYPE
In order to obtain the 3 way pressure
compensated version the cavity T have be
closed on the subplate.
In order to obtain the 2 way pressure
compensated version the cavities P and T
have be closed on the subplate.
Valves are available in the following ver-
sions (see hydraulic symbol):
- 2 way pressure compensated - 3 way
pressure compensated with priority func-
tion.
- 3 way pressure compensated with priority
and venting function.
XQP.3...
"D15P" PROPORT. SOLENOIDS CH. VIII PAGE 21
REM.S.RA... CH. IX PAGE 4
SE.3.AN.21.00... CH. IX PAGE 11
BC.06.XQP3... CH. VII PAGE 13
DIAGRAMS
I (%)
Q (l/min)
INPUT SIGNAL
FLOW
p (bar)
Q (l/min)
P - FLOW RATE A
B
(WITH 5 l/min TO P)
p (bar)
Q (l/min)
P - SECONDARY LINE FLOW
(A
P FREE)
P (bar)
Q (l/min)
FLOW RATE
BACK
PRESSURE ON PRIORITY LINE
Q (l/min)
P (bar)
FLOW RATE
BACK
PRESSURE ON SECONDARY LINE
Q (l/min)
P (bar)
2 WAY COMPENSATION
(A VARIABLE - B 30
bar)
P (bar)
Q (l/min)
2 WAY COMPENSATION
(A 270
bar - B VARIABLE)
File: XQP3002_E 01/2010/eVIII 21
8
OPERATING SPECIFICATIONS
Max. operat. pressure ports A/B /P see note (*) With T port blocked on subplate 250 bar
Regulated flow rate 6 / 12 / 22 / 32 / 40 l/min
Decompression drain flow max 0,7 l/min
Relative duty cycle Continuous 100% ED
Type of protection (in relation to the connector used) IP 65
Flow rate gain See diagram "Input signal flow"
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -20°C ÷ 75°C
Ambient temperature -20°C ÷ 70°C
Max. contamination level from class 7 to 9 in accordance
with NAS 1638 with filter ß
10
75
Weight 1,7 Kg
Max. current 2.33A 1.76 A 0.88 A
Solenoid coil resistance at 25°C (77°F) 2.25 Ohm 4.0 Ohm 16.0 Ohm
Hysteresis with p 7 bar 5 % <5% <8%
Response to step p = 7 bar
0 ÷ 100% 32 ms 40 ms 85 ms
100% ÷ 0 33 ms 33 ms 33 ms
Frequency response -3db (Input signal 50% ± 25% Vmax.)
22Hz 22Hz 12Hz
(*) Pressure dynamic allowed for 2 millions of cycles
Operating specifications are valid for fluids with 46 mm
2
/s viscosity at 40°C, using
specified ARON electronic control units.
Performance data are carried out using the specified Aron power amplifier
SE.3.AN... powered to 24V.
XQP.3... OPEN LOOP 2/3 WAY PROPORTIONAL PRESSURE
COMPENSATED
FLOW REGULATORS
AMPLIFIER UNIT AND CONTROL
REM.S.RA.*.*...
Electronic card for control single proportional
solenoid valve
SE.3.AN.21.00...
Electronic card format EUROCARD for con-
trol single proportional solenoid valve
OVERALL DIMENSIONS
"D15P" PROPORTIONAL SOLENOIDS
Type of protection (in relation to connector used) IP 66
Duty cycle 100% ED
Insulation class wire H
Weight (coil) 0,354 Kg
Weight (solenoid) 0,608 Kg
ETD15P - 01/2002/e
P1 Rotary emergency
P5 Rotary emergency 180°
Support plane
specifications
Fixing screws UNI 5931 M5x25
(min. 8.8 material screws are recommended)