File: XEPV3_E 01/2010/eVIII • 13
8
INPUT SIGNAL CURVES - FLOW RATE
ORDERING CODE
The proportional directional valves XEPV are designed as direct operated components for
subplate mounting. They are actuated by means of proportional solenoids with central thread and
removable coil. The solenoids are controlled by integrated control electronics.
Features:
Integrated control electronics
Setup parameters by CAN interface
Current compensation, gain current and ramps setting
Monitoring of the valve by real time scope interface
XEPV.3... PROPORTIONAL VALVE WITH
ELECTRONIC ON BOARD
XEPV.3...
AM.3.H... CH. VIII PAGE 16
AM.5.H... CH. VIII PAGE 17
BC.3.07... CH. VII PAGE 12
XEPV Current loop proportional valve with
integrated electronics 24Vdc
3 CETOP 3/NG6
** Type of spool
01 =
spool with P, A, B
and T ports, closed
03 =
spool with P port closed,
and A, B, T ports connected
N Symmetrical flow control
* Flow rating at p 8 bar
0 = 4 l/min
1 = 8 l/min
2 = 15 l/min
3 = 25 l/min
6 = 36 l/min (we advise to use
the hydrostat AM5H3VP108)
S CAN bus communication
S = standard ARON
* Command Enable
E = with external command Enable
W = without external command Enable
* Type command
V = signal voltage ± 10V
C = signal current 4... 20mA
00 No variants
1 Serial No.
(4 l/min P
A/B) (8 l/min P
A/B)
European norms: EN 61000 - ElectroMagnetic
Compatibility (EMC) - industrial environment
(15 l/min P
A/B) (25 l/min P
A/B)
(36 l/min P
A/B)
XEPV.3.01.N...
XEPV.3.03.N...
a b
a b
with
File: XEPV3_E 01/2010/eVIII • 14
8
OPERATING SPECIFICATIONS OF VALVE WITH TRANSDUCER
XEPV.3... P
ROPORTIONAL VALVE WITH ELECTRONIC ON BOARD
OVERALL DIMENSIONS
Support plane
specifications
1.6
0.03
Fixing screws UNI 5931
M5x25 (min. 8.8 material
screws are recommended)
Tightening torque 4 ÷ 5 Nm /
0.4 ÷ 0.5 kgm
Installation must keep horizontal
Max. operating pressure ports P/A/B 350 bar
Dynamic pressure port T 210 bar
Static pressure port T 210 bar
Nominal flow 4 / 8 / 15 / 25 / 36 l/min
Performance curves See diagrams
Fluid temperature -20 ÷ 75°C (preferably 40 ÷ 50°C)
Fluid viscosity 10 ÷ 500 mm
2
/s
Max. contamination level class 7 to 9 in accordance to NAS 1638 with filter ß
10
75
Weight 2.45 kg
Nominal supply voltage 24Vdc
Input signal range (see ordering code) ± 10V or 4... 20mA
Supply voltage lower limit 18V
Supply voltage upper limit 36V
Peak power 50W
Max. coil temperature 150 °C
Duty cycle Continuous 100% ED
Hysteresis < 5%
Response sensitivity < 0.5%
Repeatibility <0.5%
Enable input command 0V = valve not active 24V = valve active
Fault signal output 0V = failure or not working valve 24V = valve OK
Current monitor ± 10V
Ambient temperature range -20 ÷ 60°C
Type of protection IP 65
Operating specifications are valid for fluids with 46 mm
2
/s viscosity at 40°C.
STEP RESPONSE (p = 8 bar P/A)
0 ÷ 100%
100% ÷ 0
File: XEPV3_E 01/2010/eVIII • 15
8
XEPV.3... PROPORTIONAL VALVE WITH ELECTRONIC ON BOARD
ELECTRICAL CONNECTIONS
Main
connector
7 ways
CAN bus
connector
5 ways
Enable - Fault
connector
5 ways
X2*: 5 ways M12 connector, CAN communication
(to be ordered separately)
Type PIN Description
1 CAN_H
CAN data 2 CAN_L
Aron interface 3
4
5 GND
* Connection cable recommended: up to 50m cable length type LiYCY
7x0.75 mm². For outside diameter see plug-in connector sketch.
Only connect screen to PE on the supply side.
X3*: 5 ways M12 connector, Enable and Fault digital command
(to be ordered separately)
Model: KVASER Leaf light HS
(not supplied, commercial parts)
The cable and D-Sub
connector are not
supplied. Assemble
the parts as shown in
the diagram.
ARON INTERFACE FOR SETUP PARAMETERS ADAPTER FOR PC: CABLE D-SUB TO CAN CONNECTOR
Aron Firetune software code: P35150005
For further information about Aron Firetune read the manual.
The software is included with valve supply.
ADAPTER FOR PC:
CABLE USB TO D-SUB
X2
Cable D-SUB to
CAN connector
Cable USB
to D-SUB
ARON
Software
X1: Main connector 7 ways (supplied with the valve)
Type PIN Description
Main power supply A +24Vdc
B 0V / common supply
0V / common of signal monitor C 0V / common of signal monitor
Input of differential signal command D ± 10V or 4...20mA
E 0V / common
Output of signal monitor F ± 10V (10V = max current)
GND GND
Connection cable recommended: up to 50m cable length type LiYCY 7x1.0
mm². For outside diameter see plug-in connector sketch. Only connect
screen to PE on the supply side.
A
GND
B
F
C
E
D
12
DIN EN 175201-804 - 7 poles female
1
2
3
4
5
5 pole
connector
1
2
3
4
5
5 pole
connector
5 ways connector
code: VE0032700
5 ways connector
code: VE0032700
IEC 61076-2-101 - 5 poles female IEC 61076-2-101 - 5 poles female
Type PIN Description
Digital output signal 1 Connects to +24Vdc
of valve FAULT 2 Signal out:
0V = failure of electronic control
24V = valve OK
Input digital command 3 Connects to 0V
of ENABLE valve 4 Connects to +24V to enable the valve
5
ARON SOFTWARE AND CABLES
1
1
6 7 8 9
2 3 4 5
2
3
4
5
D-Sub connector
(female)
CAN connector
1
4
5
6
8
9
2
3
7
1
2
5
3
4
CAN-L
GND
CAN-H
CAN-H
CAN-L
GND
A positive command value 0 to +10V (or 12 to 20mA) at D and the
reference potential at E, results in a flow from P to A and B to T.
A negative command value 0 to -10V (or 12 to 4mA) at D and the
reference potential at E, results in a flow from P to B and A to T.