8
Max. operating pressure ports P/A/B 320 bar
Max. pressure port T - for dynamic pressure see note (*) 250 bar
Max. pressure port T (with external drainage - Q5 variant) 320 bar
Nominal flow 45 / 60 / 100 l/min
Duty cycle Continuous 100% ED
Type of protection (depending on the connector used) IP 65
Flow rate gain See diagram
Power limits curves transmitted See diagram
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -20°C ÷ 75°C
Ambient temperature -20°C ÷ 70°C
Max. contamination level from class 7 at 9 in accordance with NAS 1638 with filter ß
10
≥75
Weight XDP.5.A... (single solenoid) 4,97 Kg
Weight XDP.5.C... (double solenoid) 6,55 Kg
Max. current 2.5 A 1.25 A
Solenoid coil resistance 20°C (68°F) 2.85 Ohm 11.4 Ohm
Hysteresis P/A/B/T
with a pressure compensator AM.5.H.3V... <5% <8%
Response to step ∆p = 10 bar (P/A)
0 ÷ 100% 56 ms 118 ms
100% ÷ 0 32 ms 32 ms
Frequency response -3db (Input signal 50% ±25% Vmax)
10Hz 7Hz
(*) Pressure dynamic allowed for 2 millions of cycles
Operating specifications are valid for fluids with 46 mm
2
/s viscosity at 40°C, using the
specified ARON electronic control units. Performance data carried out using the
specified Aron power amplifier type REM.S.RA... power supplied at 24V.
XDP.5.A... / XDP.5.C ... PROPORTIONAL DIRECTIONAL VALVES OPEN LOOP
AMPLIFIER UNIT AND CONTROL
REM.S.RA.*.*. and REM.D.RA.*.*.
Electronic card control single and double pro-
portional solenoid valve.
AM.5.H.2V.P1 / AM.5.H.3V.P1(
∆∆
∆∆
∆p=10bar)
Hydrostats 2 or 3 way.
E = Manual override
P1 = Rotary emergency button
Q5 = External draining hole for XDP5 variante
Q5 only (Screws: material specifications
12.9 must be used)
GSQ = Square section seal
Support plane
specifications
Fixing screws UNI 5931 M6x40
(12.9 material screws are recommended)
Tightening torque 8 ÷ 10 Nm / 0.8 ÷ 1 Kgm
OPERATING SPECIFICATIONS
"D19P"
PROPORTIONAL SOLENOIDS
Type of protection (in relation to connector used) IP 65
Ambient temperature -54°C ÷ 60°C
Duty cycle 100% ED
Insulation class wire H
Weight 1,58 Kg
ETD19P - 01/2002/e